PROBLEM
Engine will not start
Engine is running but no AC output
Repeated circuit breaker tripping
Generator overheating
Engine runs well but gets bogged
down when loads are connected
CAUSE
1. Low on fuel or oil.
2. Ignition switch in "Off" position.
3. Faulty spark plug.
4. Choke in wrong position.
5. Fuel shut-off valve is closed.
6. Unit loaded during start-up.
7. Spark plug wire loose.
1. Faulty receptacle.
2. Circuit breaker tripped.
3. Defective capacitor.
4. Faulty power cord.
1. Overload.
2. Faulty cords or equipment.
1. Generator overloaded.
2. Insufficient ventilation.
1. Electrical short in connected item.
2. Overloaded.
CORRECTION
1. Add fuel or oil.
2. Turn to "ON" position.
3. Replace spark plug.
4. Adjust choke accordingly.
5. Open fuel shut-off valve.
6. Remove load from unit.
7. Attach wire to spark plug.
1. Have Service Center replace.
2. Reset breaker.
3. Have Service Center replace capacitor.
4. Repair or replace cord.
1. Reduce load.
2. Check for damaged, bare, or frayed wires
on equipment. Replace.
1. Reduce load.
2. Move to adequate supply of fresh air.
1. Disconnect shorted load.
2. Reduce load.