background image

INTRODUCTION

INTRODUCTION

 

2

3

   This product uses the Oscillometric Measuring method to detect blood pressure. 
Before every measurement, the unit establishes a “zero pressure” equivalent to
the air pressure. Then it starts inflating the arm cuff, meanwhile, the unit detects
pressure oscillations generated by beat-to-beat pulsatile, which is used to
determine the systolic and diastolic pressure, and also pulse rate.

Features:

 

90 readings 
3rd Generation Technology: Measuring during inflation 

65mm

×

50mm Digital LCD display 

    Thank you for selecting Kinetik arm type blood pressure monitor (WBP1). 
The monitor features blood pressure measurement, pulse rate measurement
and the result storage.
    This manual contains important safety and care information, and provides
step by step instructions for using the product.
    Read the manual thoroughly before using the product.

   The Kinetik Blood Pressure Monitor is digital monitors intended for use in 
measuring blood pressure and heartbeat rate with arm circumference  
22cm to 42cm (about 8

¾

˝-16

½

˝).

It is intended for adult indoor use only.

1. The device is not suitable for use on may be pregnant women or pregnant
women.
2. The device is not suitable for use on patients with implanted, electrical
devices, such as cardiac pacemakers, defibrillators. 

Our manual should provide you with all the information you need
to set up and use this product.

 

If you have a question, have a look at our Troubleshooting page! 

For further assistance, why not contact our Customer Care team
directly? We’re here to help!

Our Customer Care team are available from 9am-5pm, Monday to

Friday (excluding bank holidays).

We promise to respond to all queries and will ensure to resolve any
issue you may be having.

 

You can reach us by…

Phone: 

+44 1483 937969

Live Chat:

Simply visit www.kinetikwellbeing.com and send us a message. 

Email:

[email protected] 

Post:

Kinetik Medical Devices Limited 
Unit 3, Perrywood Business Park, Honeycrock Lane, 
Salfords, Redhill. RH1 5DZ

Support

Measurement Principle

Contraindications

General Description

Indications for Use

Содержание WBP1

Страница 1: ...Blood Pressure Monitor Instruction Manual WBP1...

Страница 2: ...MENT 15 16 Check the memory Delete the Readings INFORMATION FOR USER 17 Tips for measurement Maintenance ABOUT BLOOD PRESSURE 18 19 What are systolic pressure and diastolic pressure What is the standa...

Страница 3: ...in measuring blood pressure and heartbeat rate with arm circumference 22cm to 42cm about 8 16 It is intended for adult indoor use only 1 The device is not suitable for use on may be pregnant women or...

Страница 4: ...st be treated with caution Observe the storage and operating conditions described in this booklet The equipment is not AP APG equipment and not suitable for use in the presence of a flammable anesthet...

Страница 5: ...d sales service centers Please report to Harvard Medical Devices if any unexpected operation or events occur Keep the unit out of reach of infants young children or pets to avoid inhalation or swallow...

Страница 6: ...is dim The display does not light up 1 Battery powered mode 6VDC 4 AAA batteries Do not use new and used batteries together Do not use different types of batteries together Do not dispose the batterie...

Страница 7: ...is stored in the memory The setting range of the year 2017 2057 Time format 24H the YEAR Each press will increase the numeral by one in a cycling manner mmHg mmHg min for 3 seconds to enter the mode...

Страница 8: ...same level as your heart Turn your palm upwards Sit upright in a chair and take 5 6 deep breaths Rest for 5 minutes before first measuring Wait at least 3 minutes between measurements This allows you...

Страница 9: ...off otherwise it will turn off within 1 minute 1 When the monitor is off please press button to show the average value of the latest three records If the records are less than 3 groups it will displa...

Страница 10: ...ken in the following circumstances 1 Within 1 hour after drinking or eating 2 Immediate measurement after tea coffee or smoking 3 Within 20 minutes after taking a bath 4 When talking or moving your ng...

Страница 11: ...records all the pulse intervals and calculate the average if there are two or more pulse intervals the difference between each interval and the average is more than the average value of 25 or there a...

Страница 12: ...nd frequently asked questions for problems you may encounter with your blood pressure monitor If the product is not operating as you think it should check here before arranging for servicing Type BF a...

Страница 13: ...cation of usability engineering to medical devices EN 62304 2006 AC 2008 IEC 62304 2006 A1 2015 Medical device software Software life cycle processes Risk management Labeling User manual General Requi...

Страница 14: ...lt Technical description Table 1 Group I Class B Not application Not application 1 all necessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFOR MANCE with regard to electromagnetic dis...

Страница 15: ...2 0 3 9 810 870 930 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18Hz 2 0 3 28 1720 1845 1970 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse m...