Compact Commercial Softener Owner
’s Manual
10
Kinetico Valve Operation
Water Meter Disc
The frequency of regeneration can be adjusted without re-gearing the system. The use of
the water meter disc provides for multiple regenerations per 360º cycle on the water
meter. Each regeneration notch on a water meter disc will initiate a regeneration when
the regeneration start pawl drops into one of these segments and engages with the teeth
of the control disc. The number of regenerations within the 360º cycle is indicated by the
number of the water meter disc.
Regeneration Pawls
It is important to realize that there are two regeneration pawls: the regeneration start pawl
and the regeneration drive pawl. The regeneration start pawl advances the control disc
enough to open the regeneration control valve. The water meter and control discs
advance together until the control disc uncovers one of the holes in the ceramic disc
located directly beneath the control disc. This opens the regeneration control valve, which
starts regeneration. Once the valve has opened, the regeneration drive pawl continues to
advance the control disc through the regeneration cycle.
When open, the regeneration control valve allows water to pass through a nozzle where it
is directed to the regeneration turbine in the regeneration chamber. As the regeneration
turbine spins, it drives the regeneration drive pawl, which advances the control disc.
Jet Regeneration
During the regeneration, water is used by the valve to control the sequence. For units
equipped with
Jet Regeneration
, a 0.2 gpm regeneration flow control is used to limit the
amount of water used. In addition to this small flow control, the regeneration nozzle in the
level two, and the regeneration turbine in the level one are also modified to accept these
lower flow rates.
In non-Jet systems, a 0.4 gpm flow control, standard regeneration nozzle and an open
regeneration turbine are used.
The Jet feature is included with all CC Systems.
Control Disc
All internal valve positions are controlled by the Control Disc. As the control disc turns, it covers and uncovers
holes in the ceramic disc (located directly below the control disc), sending pressure signals to open and close all
internal valves. The sequence of regeneration and service configuration (alternating or Overdrive) is based on the
type of control disc installed.
White
Gray
Black
Orange
Tan
Purple
Part Number
4689*
7931
4700A
8637
5565
8635
Service Flow
Alternating
Alternating
Alternating
Overdrive
Overdrive
Overdrive
Regeneration Sequence:
Backwash
--
--
--
12%
--
--
Brine • Slow Rinse
75%
89%
60%
57%
76%
--
Backwash
25%
11%
40%
12%
24%
65%
Purge
--
--
--
7%
--
25%
* Standard with all CC models
Regeneration start pawl
Regeneration drive pawl
Meter Disc 1 Meter Disc 5
Jet
regeneration
gearing &
turbine
Normal
regeneration
gearing &
turbine