![Kinetico 16486 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/kinetico/16486/16486_owners-manual_1968495008.webp)
8
Regeneration Cycle
(
NOTE:
These may need to be adjusted based on application.)
Step
Common Cycle Step Times Minutes
Step 1
Air Release (non-adjustable)
6
Step 2
Backwash
12
Step 3
Rest
5
Step 4
Air Replenish
45
Step 5
Rapid Rinse
5
NOTE:
Depending on system pressure and other factors, it is possible to observe
flow to drain in the rest cycle.
- When the valve is between positions, the display will flash the number of the step it
is moving toward.
- The default time at which regeneration will occur is 12:00 a.m.
- If system loses power and no backup battery is installed, it may return to default
settings which could be different from those entered at start-up. Consult with your
dealer.
The motor’s run direction during a particular regeneration cycle step is indicated
by the rotation direction of the last 2 digit displays.
5-
Example: