background image

Technical Manual

7

Essential Platinum

Design Specifications

Flow Rate @ 15 psid

10.0 gpm

38 Lpm

Flow Rate @ 30 psid

15.0 gpm

57 Lpm

Pressure Range

25 - 125 psi

1.7 - 8.6 bar

Temperature Range

35˚- 120˚F

2˚- 50˚C

Free Chlorine

2.0 mg/L

2.0 mg/L

Compensated Hardness

50 gpg

855 mg/L

Iron (ferrous)

<0.5 mg/L

<0.5 mg/L

Iron (ferric)

<0.01 mg/L

<0.01 mg/L

System Components

Media Vessel (Qty. 1)

9" x 35"

229 mm x 889 mm

Media Vessel Construction

Fiberglass Wrapped Polyethylene

Empty Bed Volume

1.0 cubic feet

28.3 liters

Media Type

Non-Solvent, High Capacity Cation Resin

Media Volume (per tank)

0.6 cubic feet

17 liters

Free Board

None

Riser Tube

1.05" ABS

27 mm ABS

Distributor Upper

0.012" Slots, Cone Type

0.30 mm Slots, Cone Type

Distributor Lower

0.012" Slots, Cone Type

0.30 mm Slots, Cone Type

Regeneration Control

Volumetric

Service Flow

Upflow

Regeneration Flow

Downflow

Regeneration Type

Countercurrent

Hard Water By-pass During Regeneration

Automatic

Water Used for Regeneration

Inlet Water, Unprocessed

Water Used for Brine Tank Fill

Softened

Salt Capacity (Pellet) 18" x 35" Brine Drum

200 lb

90.7 kg

System By-pass

Optional

Connections

Inlet / Outlet Connections

Custom Adapter and Bracket

Drain Connection

0.5" Quick Connect Tubing

Brine Line Connection

0.375" Quick Connect Tubing

Brine Tank Overflow

0.5" Tubing Barb

Power

None

System Part Number

Essential Platinum

15210

Essential Platinum, No Brine Drum

15195

Dimensions and Weight

Height

41.25"

1,048 mm

Width

9"

229 mm

Depth

9"

229 mm

Shipping Weight

60 lb

27.2 kg

Operating Weight

300 lb

136.1 kg

Regeneration Specifications at 35 psi

Offline Time During Regeneration Cycle

13.5 minutes

Total Regeneration Cycle Time

15 minutes

Total Regeneration Volume

9.5 gallons

36 liters

Salt Used per Regeneration

1.25 lb

0.57 kg

Salt Dose

2.1 lb / cu ft3

33.7 grams NaCl/liter resin

System Capacity

5,000 grains

324 grams

Backwash Flow Rate

2.5 gpm

9.5 Lpm

9” / 229 mm

4

1.25” / 1,

048 mm

Содержание 15759

Страница 1: ...Technical Manual Models Essential Gold 15759 Essential Platinum 15210 Kinetico ESSENTIAL S E R I E S WAT E R S O F T E N E R S...

Страница 2: ......

Страница 3: ...2 Riser Tube 12 Brine Tank 12 Brine Valve 12 V Valve Maintenance 13 Servicing the Venturi 13 System Disassembly 14 17 Maintenance 17 Valve Assembly 18 19 AccuDial Assembly 20 21 Setting the AccuDial 2...

Страница 4: ...quipment specifications section for specific instructions Consult MSDS Sheets A caution icon will be used to present any information that may hold a potential hazard or concern during the installation...

Страница 5: ...regeneration period the unit cannot make soft water To alleviate this concern two design elements are included First during a regeneration the unit automatically by passes water so the customer is ne...

Страница 6: ...pe Regeneration Control Volumetric Service Flow Upflow Regeneration Flow Downflow Regeneration Type Countercurrent Hard Water By pass During Regeneration Automatic Salt Capacity Pellet 60 lb 27 2 kg S...

Страница 7: ...egeneration Type Countercurrent Hard Water By pass During Regeneration Automatic Water Used for Regeneration Inlet Water Unprocessed Water Used for Brine Tank Fill Softened Salt Capacity Pellet 18 x 3...

Страница 8: ...t to a 0 8 lb salt setting This can be confirmed by measuring the distance of the float cup from the top of the fixed adjuster tube This distance is 0 50 inches drawing not to scale Essential Platinum...

Страница 9: ...ation process the by pass chamber is open providing a flow connection between inlet and outlet Water Metering The amount of water metered between a regeneration will be based on three factors the conf...

Страница 10: ...generation gearing connects the regeneration turbine to the stem gear and eccentric pin which drives the regeneration drive pawl and advances the control disc Regeneration Control Disc All valve posit...

Страница 11: ...red in the level 4 These valves include inlet by pass outlet valve and spring loaded control valve The servo valves are operated by the control disc Together these valves control the flow of water thr...

Страница 12: ...spots in the media tank The design of the distributors also keeps the resin inside the tank as the slots on the distributor are sized smaller than the minimum size of the resin beads Riser Tube A ris...

Страница 13: ...enturi 5 Snap fit new venturi 6 Lubricate O rings with silicone 3 places Use small screwdriver to pry venturi out of plug insert screwdriver near tab Snap fit in after lining up tabs on venturi with m...

Страница 14: ...3 Depressurize system Depress and turn actuator clockwise 4 Disconnect and remove by pass 5 Disconnect brine line and drain line 6 Remove brine valve 7 Remove salt 8 Remove valve 9 Unbolt valve Unbol...

Страница 15: ...2 philips screwdriver 16 Disassemble AccuDial metering 17 Remove upper disc 18 Remove meter drive pawl 19 Remove no back pawl and spring 20 Remove balance piston and O ring 21 Remove balance piston sp...

Страница 16: ...d re move check stem 29 Isolate level 3 4 5 assembly 30 Remove by pass seat Hold valve seat Unscrew 31 Separate level 3 from 4 5 and remove level 3 32 Remove drain valve seat 33 Separate level 4 from...

Страница 17: ...move control valve Pull Maintenance Service venturi Unscrew using a 1 4 nut driver Service regeneration flow control and filter disc Regeneration flow control orientation Service backwash flow control...

Страница 18: ...rt outlet piston into level 4 5 Add seats to inlet and outlet valves 6 Insert BWFC into level 4 Outlet Position Push Screw 7 Place level 5 seal on level 5 8 Place level 4 subassembly on level 5 9 Plac...

Страница 19: ...19 13 Place 3 4 5 assembly on level 6 14 Place level 3 seal on 3 4 5 6 assembly 15 Place level 1 assembly on 3 4 5 6 16 Bolt valve together Use a 1 4 nut driver and tighten to 1 69 Nm 15 in lbs in a...

Страница 20: ...drive pawl with spring 4b Regeneration drive pawl with spring in place 5a Add a regeneration start pawl with spring 5b Regeneration start pawl with spring in place 6a Add no back pawl and spring 6b No...

Страница 21: ...re arrow is aligned at 6 o clock position 11 Insert return spring into cap 12 Insert actuator and O ring into cap 13 Add cap O ring 14 Align superdisc 15 Attach cap to level 1 16a Bolt valve 6 00 Make...

Страница 22: ...al Regeneration Using a 2 Phillips screwdriver push down firmly on the softener valve screw and slowly turn clockwise listening for four 4 clicks to start the regeneration At this point you should hea...

Страница 23: ...wn the central distributor tube and up through the resin bed 7 Control Flow When the set point volume has metered through the Solitaire valve determined by the hardness setting on the AccuDial the con...

Страница 24: ...stributor tube Then the brine flows out the drain valve to the drain line 12 Slow Rinse During slow rinse there is no change in the position of the internal valves in the Solitaire valve If the satura...

Страница 25: ...lose by pass step the inlet by pass valve switches to the inlet position During this step the brine line is pressurized and the cabinet brine drum is refilled through both the nozzle and throat sides...

Страница 26: ...R 3 4 1 SWEAT 3748 BRASS IN OUT ADAPTER THREADED 3 4 NPT 7841 BRASS IN OUT ADAPTER 1 1 1 4 SWEAT 10081B STRAIGHT THREAD IN OUT ADAPTER 3 4 straight thread can be used with hose connection do not use w...

Страница 27: ...nd Part Number Description 14201 STRAIGHT THREAD IN OUT ADAPTER KIT 1 x 1 1454A BRASS IN OUT ADAPTER KIT 3 4 1 SWEAT 1483A PVC IN OUT ADAPTER KIT 1 GLUE 3801A BRASS THREADED IN OUT ADAPTER KIT 3 4 NPT...

Страница 28: ...VALVE 3 4 STRAIGHT THREAD straight thread can be used with hose connection do not use with NPT fittings 15317 BLENDING BY PASS VALVE 1 NPT 14894 LONG BLENDING BY PASS VALVE 3 4 STRAIGHT THREAD straigh...

Страница 29: ...y 4 Run soft water to service Metering Rate Gold Platinum 10 0 gallons per tooth Verify metering Watch the AccuDial Is it advancing clockwise Watch the no back pawl as the AccuDial advances clockwise...

Страница 30: ...unit in backwash and a faucet running timing how long it takes to fill the container Essential Gold backwash rate 1 0 gpm Essential Platinum backwash rate 2 5 gpm 1 gallon 38 seconds 2 5 gpm 1 gallon...

Страница 31: ...line C Damaged outlet main valve seat seal A Clean flow control venturi throat and Nozzle note do not use paper clip B Clean replace flow control free obstruction from drain line C Replace main valve...

Страница 32: ...wash cycle A Control flow path is plugged at the regeneration nozzle or regeneration flow control B Regeneration drive pawl and or spring is weak or broken C Damaged tooth on control disc D Eccentric...

Страница 33: ...e damaged by chlorine or chloramines A Replace main valve piston quad rings B Replace small retainer quad rings in level 4 or replace level 4 the piston shafts seal against these quad rings and they c...

Страница 34: ...Meter Disc A J Gold 16023A Lower Meter Disc 10 Platinum 14818B 10 Solitaire Control Disc 14712C 11 Solitaire Level One w Cer Stem Gear Asy 14755A 12 AccuDial Lockout Clip ALC 16213 13 Regeneration Dri...

Страница 35: ...el Three Assembly Parts Dwg No Description Part No 1 SS Cap Screw 1010 2 Venturi Access Plug w O rIng 14807 3 Solitaire Venturi Tan Essential Gold 14809 Solitaire Venturi Orange Essential Platinum 148...

Страница 36: ...at w Seal 13696 7 Seal Only Seat 14725 8 Quad Ring 125 Piston 1550 9 Quad Ring 110 Internal Not Shown 1590 10 Seal Main Seat 7865 Level 5 Assembly Parts Dwg No Description Part No 1 Solitaire Level Fi...

Страница 37: ...Screw 14703A 2 Solitaire Main Valve Nut 14741 3 In Out Tank Adapter O ring 122 1328 4 O ring 148 Cap Seal 14745 5 Solitaire Level Three Seal 14727 6 Solitaire Level Four Seal 14733 7 Solitaire Level F...

Страница 38: ...d Tubes Essential Gold Dwg No Description Part No 1 Distributor Tube 15856 2 8 x 17 Media Tank 15801 3 Brine Valve Assembly 15804 4 Cabinet Assembly 15802 5 Overflow Elbow 1138A 6 Overflow Nut 1139A 7...

Страница 39: ...sential Platinum Dwg No Description Part No 1 Distributor Tube 13433 2 9 x 35 Media Tank 15316 3 Brine Valve Assembly 7805 4 18 x 35 Brine Drum Assembly 15062 Standard Mesh H C Resin 13683 Polypropyle...

Страница 40: ...www kinetico com Part No 15760B Rev 02 21 2020...

Отзывы: