Factory Defaults
© 2017 Kinesys Projects Ltd
3
Factory Defaults
If a LibraCELL is powered up with the 'M' button pressed, it will revert back to factory
defaults. Calibration and offset settings will be preserved.
4
The Default Display
The default display menu will show the current load in kg. The activity indicator in the top
corner of the display will flash once a second to indicate that the cell is working.
The tare indicator is illuminated if the cell has a tare offset value set, this indicates that the
load being displayed is the total load minus the tare value.
If the Ib indicator is lit the cell is in imperial mode and is displaying the load in lbs. Whilst in
imperial mode values entered for Tare, MIN and MAX will be in lbs.
If the displayed load is above the maximum trip value the display will flash alternately
between the load and the message “MAX”. If the displayed load is below the minimum trip
value the display will flash alternatively between the current load and the message “MIN”.
Whilst in the default display mode, and if no trips are displayed, pressing the up button
will cause the cell to display the Tare offset. Pressing the down button will cause the cell to
display its communications address.
5
Operation
To ensure the optimum performance and accuracy of the LibraCELL the following
guidelines should be followed.
1. From 1 February 2011 all LibraCELLs are tagged with a unique 5 digit identifier, this
features on the bow as a tag and is etched onto the inside of the load pin.