Factory Defaults

© 2017 Kinesys Projects Ltd

3

Factory Defaults

If  a  LibraCELL  is  powered  up  with  the  'M'  button  pressed,  it  will  revert  back  to  factory
defaults. Calibration and offset settings will be preserved.

4

The Default Display

The default display menu will show the current load in kg. The activity indicator in the  top
corner of the display will flash once a second to indicate that the cell is working. 

The tare indicator is illuminated if the cell has a tare offset value set, this indicates that the
load being displayed is the total load minus the tare value.

If the Ib indicator is lit the cell is in imperial mode and is displaying the load in lbs. Whilst in
imperial mode values entered for Tare, MIN and MAX will be in lbs. 

If  the  displayed  load  is  above  the  maximum  trip  value  the  display  will  flash  alternately
between the load and the message “MAX”. If the displayed load is below the minimum trip
value the display will flash alternatively between the current load and the message “MIN”.

Whilst in the  default  display  mode,  and  if  no trips  are  displayed,  pressing  the  up  button
will cause the cell to display the Tare offset. Pressing the down button will cause the cell to
display its communications address.

5

Operation

To  ensure  the  optimum  performance  and  accuracy  of  the  LibraCELL  the  following
guidelines should be followed.

1. From 1  February  2011  all  LibraCELLs  are  tagged  with a  unique  5  digit  identifier,  this

features on the bow as a tag and is etched onto the inside of the load pin.

Содержание LibraCELL

Страница 1: ... 2017 Kinesys Projects Ltd LibraCELL Manual Version 1 6 5 Product Manual ...

Страница 2: ...rademarks While every precaution has been taken in the preparation of this document the publisher and the author assume no responsibility for errors or omissions or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it In no event shall the publisher and the author be liable for any loss of profit or any other...

Страница 3: ...ntents Part 1 Introduction 4 Part 2 Power On 4 Part 3 Factory Defaults 5 Part 4 The Default Display 5 Part 5 Operation 5 Part 6 Editing A Parameter Via The Keypad 7 Part 7 Connections 8 Part 8 Adjusting The Zero Offset 9 Part 9 Contact Information 10 ...

Страница 4: ...aintains a safety factor of 5 1 up to the full rated load The3 25T 5 8 and 4 75T 3 4 versions allow 10 1 safety factors to be applied while still allowing sufficient capacities to rig one and two tonne points respectively The LibraCELL technology has the ability to resolve down to 1kg 2 2lbs Due to limitations in the manufacture of the Crosby shackle bow Kinesys specify an accuracy of 2 of the cur...

Страница 5: ...ad in lbs Whilst in imperial mode values entered for Tare MIN and MAX will be in lbs If the displayed load is above the maximum trip value the display will flash alternately between the load and the message MAX If the displayed load is below the minimum trip value the display will flash alternatively between the current load and the message MIN Whilst in the default display mode and if no trips ar...

Страница 6: ...gether can result in the LibraCELL producing less accurate readings 2 The Crosby and Kinesys logos should be on the same side of the LibraCELL LibraCELLs that feature a 5 digit unique identifier tag will be on the inside of the bow A LibraCELL with the bow fitted correctly A LibraCELL with the bow fitted incorrectly 3 The nut that holds the bow and load pin together should always be fully tightene...

Страница 7: ... to revert to the normal display mode Parameter edit mode When the desired parameter is selected pressing the M button will cause the display to enter the parameter edit mode If the currently selected parameter cannot be changed the display will show for as long as the M button is pressed If the currently selected parameter can be edited the display will show its value and the up and down buttons ...

Страница 8: ...rial lbs kg Max Yes Set the load over which the display will flash tmax 0 No Trip Min Yes Set the load under which the display will flash tmin 0 No Trip Disp Yes Set the display YES or NO YES Log No Display the maximum load read by the cell since the log was last reset 0 Rate No Rating of the cell maximum load Date No Calibration Date MMYY Ver No Display the version of the firmware in the cell 7 C...

Страница 9: ... cells use a scaling factor of 3611 For 4 75T cells use a scaling factor of 5278 8 Adjusting The Zero Offset All LibraCELLs are calibrated when they leave the factory during the lifetime of the cell the zero point of the LibraCELL can drift slightly resulting in reduced accuracy This is often seen as the LibraCELL registering a weight when load applied If this occurs the end user has the option to...

Страница 10: ...12 2HT to find us Google Map Link http www google co uk maps q tw122af Feedback We are always keen to hear feedback from the users of Kinesys products If you have a feature request for the software any comments about the documentation or just want to say hello please get in touch In the unlikely event that LibraVIEW has not performed to the high standards that we work to and our users expect then ...

Отзывы: