4.7
Replacing the battery
4.7.1
Unscrew Battery retaining cap situated at the front right of the fire and
remove the battery
4.7.2
Replace in the reverse order using a 1.5V AA Alkaline Battery.
4.8
Removing the Oxy-Pilot Assembly
Note: Because this appliance is fitted with an atmosphere sensing ‘Oxy-
Pilot’ it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
4.8.1
Remove the burner assembly as in section 4.1
4.8.2
Unscrew and remove the thermocouple retaining nut from the end of the
control tap, disconnect the ignition lead from the pilot electrode and the
two inline leads from the microswitch.
4.8.3
Unscrew and remove the two pozi-drive screws which secure the pilot
assembly to the burner. Remove the pilot.
4.8.4
Re-assemble in reverse order and carry out a gas tightness test.
4.9
Replacing the Control Cable
4.9.1
The control lever operating cable
can be seen running across the
base of the fire, below the burner.
To release the cable, unscrew the
cable securing screw located in the
centre of the aluminium operating
arm and pull the cable out from its
fixing hole. Release the other end
of the cable by pushing the cable
towards the right i.e. into the
operating arm so as to release the
tension. Pull the cable nipple out
of the retaining hole and remove
the cable through the slot in the
operating arm. See fig. 20 opposite
28
Note : Prior to replacing the oxypilot on this product due to suspected
failure of the component, please remove all debris that has collected on
the lint guard of the oxypilot itself.
Fig. 20