2.6
FITTING OF THE EFFICIENCY BAFFLE.
2.6.1
The product is supplied with an efficiency baffle to improve the
efficiency of the product when installed into Class 1 flues, of minimum
diameter 175mm / 7” or brick built 225mm x 225mm chimneys. The
minimum effective height of all flues must be 3 metres or above.
2.6.2
If the product is to be fitted into a Class 1 flue, it may be desirable to fit
the efficiency baffle.
2.6.3
If the product is fitted into a Class 2 flue of diameter 125mm / 5” then
the restrictor baffle must not be fitted. It should also be noted that if
fitting into a 125mm / 5” diameter flue that the minimum effective height
of the flue is 4 metres.
2.6.4
To fit the efficiency baffle (supplied in the loose items pack), use the 4
screws supplied to secure the baffle to the spigot on the rear of the
firebox as shown below in Fig. 13
Fig. 13
2.7
FITTING OF THE BATTERIES
2.7.1
The battery pack on SIT equipped models is at the front of the product
in the centre. Fit the 6 off AA batteries supplied.
2.7.2
The batteries on the Mertik Maxitrol equipped models are on the left
hand side, in the receiver unit. Slide the cover off and replace with 4 off
AA batteries.
12