Kind DD+ series Скачать руководство пользователя страница 8

Page  8

KIND DD+ models Power Amplifiers

models

DD+

1. Rack mounting ears

Two  front  panel  mounting  holes 

are  provided  on  each  mounting 

ear.

2. Standard rack handles

Comfortable  handles  are  pro-

vided  for  easy  transport  and 

mounting operation.

3. Input attenuators

Two  front  panel  precision  21 

steps  input  attenuators  adjust 

level for their respective amplifier 

channels.  Minimum  attenuation 

(-0dB)  equals  maximum  output.  

In  the  bridge  mode  both  level 

attenuators must be at the same 

position. We recommend  that 

you  set  them  to  the  -0dB  (full) 

position.

4. Signal bar LED

Each  channel  has  a  bar  LED, as 

the  input  signal  strength  increa-

ses,  the  green  SIGNAL,  -20dB, 

and yellow -10dB LED indicators 

light respectively at 0.1%, 1%, and 

10% of full power.

5. Clip/Limiter LED

Each channel has a LED that light 

at  the  real  clipping  point  (more 

than  0.5% T.H.D.)  and  indicates 

also:  clip  limiter,  L.S.C.  (Load 

Security  Control)  engaged  cir-

cuits.

6. Protect LED

Each  channel  has  a  Protect  LED 

that will light when: the load con-

nected is lower than 1 Ohm, the 

amplifier’s  output  as  been  shor-

ted.

7. Exp/DSP LED

The  unit  has  one  Exp  LED  that 

will light when an optional expan-

sion board like a DSP or remote 

control  will  plugged  inside  the 

unit.

8. TEM/hi-Temp LED

In  case  of  inadequate  ventilation 

the  heatsink  temperature  will 

start to rise. At 60°C the the Hi-

Temp  LED  will  start  to  blinking 

and  the  output  power  will  be 

gradually  reduced. At  75°C  the 

Hi-Temp LED will remain light on, 

and both channels will be muted 

until  temperature  decrease  to 

normal  operating  level  with  an 

automatic reset system.

9. Power LED

The green Power LED illuminates 

to  indicate  that  the  amplifier  is 

turned on, and works correctly.

10. AC power switch

Use this to switch on the ampli-

fier. A soft-start system limits the 

start-up surges.

11. Fan intake grill filter

One grill with foam filter is loca-

ted on the front panel to prevent 

dust  from  entering  the  amplifier. 

For easy cleaning of the filter the 

grill  is  removable  by  simply  pul-

ling  it  off. The  foam  filter  should 

always be used. The fan’s variable 

1. Supporti di montaggio

Due  fori  per  il  montaggio, ogni 

lato, sono  previsti  sul  pannello 

frontale.

2. Maniglie rack standard

Comode  maniglie  sono  fornite 

per  facilitare  operazioni  di  tra-

sporto e montaggio.

3. Attenuatori di ingresso

Due  attenuatori  di  precisione  a 

21  posizioni  regolano  il  livello 

del  loro  rispettivo  canale  del-

l'amplificatore.  Minima  attenua-

zione  (-0dB)  uguale  a  massima 

uscita. Nell'uso in mono a ponte 

entrambi gli attenuatori di livello 

devono  essere  nella  stessa  posi-

zione. Si  raccomanda  di  impo-

starli sulla posizione -0 dB (full).

4. Signal barra LED

Ogni  canale  ha  una  barra  LED,  

col  salire  del  segnale  d’ingresso, 

i  LED  verdi  SIGNAL,  -20dB,  e 

giallo -10dB si illuminano rispetti-

vamente al 0.1%, 1%, e 10% della 

massima potenza.

5. Clip/Limiter LED

Ogni canale ha un LED che si illu-

mina al punto di clip reale (oltre 

lo  0.5% T.H.D.)  e  indica  anche: 

l'intervento  del  limiter  e  l’intrer-

vento  dell’L.S.C. (Load  Security 

Control). 

6. Protect LED

Ogni  canale  ha  un  LED  di  pro-

tezione che si illumina quando: il 

carico collegato è al di sotto di 1 

Ohm,  l’uscita  dell’amplificatore  è 

stata cortocircuitata. 

7. Exp/DSP LED

L’unità ha un LED Exp che si illu-

mina quando una board di espan-

sione opzionale come  un DSP o 

un controllo remoto viene inseri-

ta all’interno dell’unità.

8. TEM/hi-Temp LED

In caso di ventilazione inadeguata

la  temperatura  del  dissipatore 

comincerà  ad  alzarsi. A  60°C  il 

LED  Hi-Temp  comincerà  a  lam-

peggiare  e  la  potenza  d’uscita 

verrà  gradualmente  ridotta. A 

75°C  il  LED  Hi-Temp  rimar-

rà  acceso,  e  ambedue  i  canali 

andranno  in  mute  fino  a  che  la 

temperatura  torna  ad  un  livello 

normale, il reset avviene in auto-

matico.

9. Power LED

Il  LED  verde  Power  si  illumina 

per indicare che l'amplificatore é 

acceso e lavora correttamente. 

10. Pulsante di accensione

Usatelo  per  accendere  l'amplifi-

catore.  Un  sistema  di  soft-start 

limita  l'assorbimento  all’accen-

sione. 

11. Griglia di aspirazione 

del ventilatore e filtro

Sul pannello frontale si trova una 

griglia  con  filtro  in  spugna  per 

prevenire  l’ingresso  della  polve-

re  nell’amplificatore. Per  la  puli-

zia del filtro, la griglia può essere 

rimossa  semplicemente  tirando-

Содержание DD+ series

Страница 1: ...DD 4000 PROFESSIONAL POWER AMPLIFIER 7 10 Inf 16 0dB 1 3 5 12 20 40 7 10 Inf 16 0dB 1 3 5 12 20 40 CLP LIM SIG 20 10 PRO TEM DSP PWR A B PRO CLP LIM SIG 20 10 POWER ON POWER OFF A channel B channel D...

Страница 2: ...t registers radiators or other heat produ cing devices 12 Do not block intake or exhaust ports Do not operate equip ment on a surface or in an environment which may impede the normal flow or air aroun...

Страница 3: ...iew 7 Operation 10 Configuration 13 Protection Features 14 Service Information 15 Technical Specifications 16 Indice Informazioni per la Garanzia 4 Dichiarazione di Conformit 5 Responsabilit dell uten...

Страница 4: ...ligenza incidente impropria installazio ne oppure dove i dati o i codici sono stati rimossi o cancellati INFORMATIONS DE G A R A N T I E ITALIE seulement con sultez votre marchand ou distributeur GARA...

Страница 5: ...O N I I N U S C I T A PERICOLOSE Gli amplificatori sono in grado di genera re tensioni di uscita pericolose al connettore degli altoparlanti Per prevenire il rischio di scossa elettrica non toccare g...

Страница 6: ...and transmitters sia conforme ai limiti di immunit EMC deve recare il marchio CE In caso contrario contattare il produttore o rivenditore Tutti i dispositivi elettrici venduti nella CEE devono essere...

Страница 7: ...Ch A Ch B 1 1 2 Ch B 2 1 1 2 2 STEREO OUT B Ch B Ch B Ch A Ch A Spk 1 2 Spk BRIDGE WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Serial No CAUT...

Страница 8: ...it off The foam filter should always be used The fan s variable 1 Supporti di montaggio Due fori per il montaggio ogni lato sono previsti sul pannello frontale 2 Maniglie rack standard Comode manigli...

Страница 9: ...manual la Il filtro in spugna dovrebbe sempre essere usato Il controllo a velocit variabile della ventola assicura un basso rumore ope rativo e adatta la quantit di aria richiesta in base alla temper...

Страница 10: ...Factory set is 32dB Gain Utilizzo Connessione alla rete e assorbimento L assorbimento dell amplificato re stimato a riposo a 1 8 e a 1 3 della potenza severa con dizione musicale L assorbimento massi...

Страница 11: ...lle gati in parallelo Questo NON un parallel mono Non collega re mai i terminali di uscita posi tivi a massa oppure in paralle lo Potreste usare i connettori d ingresso rimanenti per colle gare altri...

Страница 12: ...h A Ch B 1 1 2 Ch B 2 1 1 2 2 STEREO OUT B Ch B Ch B Ch A Ch A Spk 1 2 Spk BRIDGE WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Serial No CAUTIO...

Страница 13: ...Schede Opzionali DSP e Controllo remoto VERDE J5 Ch A J9 Ch B Positione Aperto Scheda Presente Positione Chiuso Scheda non Presente Positione di Default Chiuso Signal By pass for DSP and Remote contro...

Страница 14: ...put stage and the SMPS Switching Mode Power Supply will be inhibited Caratteristiche delle pro tezioni Ogni modello incorpora delle protezioni sofisticate Sono deri vate dall esperienza di KIND con in...

Страница 15: ...tor Dealer or KIND Audio Italy Limitazione assorbimen to AC Un sistema di soft start riduce l assorbimento all accensione un requisito essenziale in una situa zione con amplificatori multipli Protezio...

Страница 16: ...50 dB Gain and Level Input Sensitivity 4 ohms 32 dB gain 3 1 59 V 1 78 V 2 16 V 2 36 V 2 56 V 1 38 V 1 59 V 1 78 V 2 07 V 2 30 V Input Gain Selectable DIP switches on rear panel 26 29 32 35 38 41 44d...

Отзывы: