kincrome KP87006 Скачать руководство пользователя страница 9

9

UNIVERSAL BATTERY CHARGER &  

MAINTAINER  

12V 25 AMP

reach this within 24 hours, the safety timer protection will stop the unit from charging 
and the RED Fault LED will start flashing and the BLUE Bulk LED will be ON.

•  Absorption Charging - GREEN Absorption LED ON 

Uses a constant Voltage while reducing the charging output current to ensure the battery 
receives a full charge without overcharging the battery. 

•   Equalisation Charging - BLUE Bulk LED and GREEN Absorption LED both flashing  

A well proven process that carefully overcharges the battery to restore it’s full capacity.  
The Equalisation stage for CALCIUM Battery type selection is automatic. The Equalisation 
stage for AGM&WET and GEL Battery Types only occurs if the initial start Voltage is below 
11V DC

•  Battery Analysis - GREEN Full LED ON 

The battery analysis stage checks the condition of the battery after the charge cycle is 
completed. If the battery Voltage drops too quickly during the analysis mode, this means 
the battery is probably faulty.  If the battery analysis failed, the GREEN Full LED flashing.

•  Float Mode - Full GREEN LED ON 

This stage allows you to keep the charger connected 24/7 to ensure your battery is well 

maintained and kept 100% fully charged. Float mode will maintain the battery at a constant  

13.6V DC. 

•  Long Term Maintenance - Full GREEN LED ON 

During long term maintenance / float mode, the unit will apply a special pulse charge to 

ensure the battery is kept in optimal condition.

4. Disconnecting the Battery charger from Battery

•  If the Battery is out of the vehicle:

  

(1) Switch OFF and Remove the AC Pin Plug from the outlet.

      

(2) Remove the BLACK (-) lead and then the RED (+) lead.

•  If  the battery is still in the vehicle:

  

(1) Switch OFF and Remove the AC Pin Plug from the outlet.

  

(2) Remove the BLACK (-) lead from the vehicle chassis.

  

(3) Remove the RED (+) lead from the battery.

Note: Check electrolyte levels if possible after charging as they may need topping up with 
distilled water (This does not apply to sealed maintenance free batteries).

KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd   9

18/04/2018   2:15 PM

Содержание KP87006

Страница 1: ...NATION RECONDITIONING TECHNICAL EXPERIENCE N E E D E D NO 100 AUTOMATIC SMART BATTERY CHARGER MAINTAINER ANALYSIS BATTERY CONDITION MICROPROCESSOR CONTROLLED FULLY PATENTED BATTERY REJUVENATION RECOND...

Страница 2: ...15 to 50 C Storage Temperature 25 to 85 C Operating Humidity 90 RH Max Temperature Compensation 25mV C C Dimensions 279 x 141 x 67mm Weight 2kg Approvals CE AS NZS EMC Table of Contents Know Your Pro...

Страница 3: ...r on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don t short circuit the battery...

Страница 4: ...ently connected all year round The intelligent charger will monitor the battery Voltage and will maintain it at peak performance with a special pulse charge during long term maintenance Short circuit...

Страница 5: ...CHARGING ON BULK CHARGING POWER SUPPLY ON UNIT IN POWER SUPPLY MODE 25A LED WILL ALSO BE ON NOTE IF THE FAULT LED IS ON WHILE IN POWER SUPPLY MODE THIS INDICATES EITHER SHORT CIRCUIT REVERSE POLARITY...

Страница 6: ...ON This prevents the charger from being damaged if the positive and negative crocodile clips or the optional ring terminals accidently touch each other while the charger is turned ON ECO MODE This Ki...

Страница 7: ...e RED Crocodile clip or ring terminal to the battery terminal Connect the BLACK Crocodile clip or ring terminal to the battery terminal Fig 1 CAUTION The Temperature Sensor should be connected to the...

Страница 8: ...ning charge is used to repair the sulphated battery This unique patented feature will break down and dissolve the lead sulphate crystal build up on the battery plates which will extend the life of you...

Страница 9: ...kly during the analysis mode this means the battery is probably faulty If the battery analysis failed the GREEN Full LED flashing Float Mode Full GREEN LED ON This stage allows you to keep the charger...

Страница 10: ...10 UNIVERSAL BATTERY CHARGER MAINTAINER 12V 25 AMP CHARGING CURVE Can also be activated manually KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1 0 indd 10 18 04 2018 2 15 PM...

Страница 11: ...Battery has a damaged cell Over temperature protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t co...

Страница 12: ...entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods f...

Отзывы: