4

UNIVERSAL BATTERY CHARGER &  

MAINTAINER  

12V 25 AMP

•  Ultra lower power consumption (ECO Mode)
•  Multi Stage:

1 - Qualification - Battery condition check
2 - Battery rejuvenation (recondition mode)
3 - Soft start charging
4 - Bulk charging
5 - Absorption charging
6 - Equalisation charging
7 - Battery analysis
8 - Float mode 

9 - Long term maintenance pulse charge 

•  Automatic diagnosis and charge: On power up, the charger will automatically diagnose 

the battery condition and determine if the rejuvenation mode (reconditioning) or charge 
cycle is required.

•  Patented battery rejuvenation technology:  The charger has a unique and patented 

rejuvenation feature which uses high Voltage equalising and peak pulse reconditioning 
to repair sulphated batteries. This feature is fully automatic and depends on the internal 
impedance of the battery. 

•  Can be left on 24/7 to ensure your battery is always maintained and fully charged:  

The battery charger can be left unattended and left permanently connected all year 
round. The intelligent charger will monitor the battery Voltage and will maintain it at 
peak performance with a special pulse charge during long term maintenance.

•  Short circuit and reverse polarity protection 
•  Heavy-duty and corrosion-resistant output connectors
•  Crocodile clips and ring terminals: It comes with 2 different kinds of connectors,  

crocodile clips and ring terminals. The ring terminals are part of the crocodile clips. 
You’ll need and Alan key to remove the Crocodile clips from the ring terminal if you 
require this connection type.

•  Rapid Charge Mode: Uses maximum charging current to ensure the fastest charge 

time. You may here the fan turn ON during this mode. 

•  Silent Charge Mode (Night Mode): Charges at a reduced charge rate so the cooling fan 

is not required. 

•  Maintenance Mode: Ideal and recommended for long term maintenance charging or for 

charging smaller batteries.

•  Power Supply Mode: Press & Hold the Charge Rate button for 3 seconds to activate and 

deactivate Power Supply Mode. When in Power Supply Mode, the Power Supply LED will 
be ON.

RED

BLACK

RED

CONNECTION

 

IN

 

VEHICLE

(

NEGATIVELY

 

EARTHED

)

RED

BLACK

CONNECTION

 

IN

 

VEHICLE

(

POSITIVELY

 

EARTHED

)

BLACK

KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd   4

18/04/2018   2:15 PM

Содержание KP87006

Страница 1: ...NATION RECONDITIONING TECHNICAL EXPERIENCE N E E D E D NO 100 AUTOMATIC SMART BATTERY CHARGER MAINTAINER ANALYSIS BATTERY CONDITION MICROPROCESSOR CONTROLLED FULLY PATENTED BATTERY REJUVENATION RECOND...

Страница 2: ...15 to 50 C Storage Temperature 25 to 85 C Operating Humidity 90 RH Max Temperature Compensation 25mV C C Dimensions 279 x 141 x 67mm Weight 2kg Approvals CE AS NZS EMC Table of Contents Know Your Pro...

Страница 3: ...r on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don t short circuit the battery...

Страница 4: ...ently connected all year round The intelligent charger will monitor the battery Voltage and will maintain it at peak performance with a special pulse charge during long term maintenance Short circuit...

Страница 5: ...CHARGING ON BULK CHARGING POWER SUPPLY ON UNIT IN POWER SUPPLY MODE 25A LED WILL ALSO BE ON NOTE IF THE FAULT LED IS ON WHILE IN POWER SUPPLY MODE THIS INDICATES EITHER SHORT CIRCUIT REVERSE POLARITY...

Страница 6: ...ON This prevents the charger from being damaged if the positive and negative crocodile clips or the optional ring terminals accidently touch each other while the charger is turned ON ECO MODE This Ki...

Страница 7: ...e RED Crocodile clip or ring terminal to the battery terminal Connect the BLACK Crocodile clip or ring terminal to the battery terminal Fig 1 CAUTION The Temperature Sensor should be connected to the...

Страница 8: ...ning charge is used to repair the sulphated battery This unique patented feature will break down and dissolve the lead sulphate crystal build up on the battery plates which will extend the life of you...

Страница 9: ...kly during the analysis mode this means the battery is probably faulty If the battery analysis failed the GREEN Full LED flashing Float Mode Full GREEN LED ON This stage allows you to keep the charger...

Страница 10: ...10 UNIVERSAL BATTERY CHARGER MAINTAINER 12V 25 AMP CHARGING CURVE Can also be activated manually KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1 0 indd 10 18 04 2018 2 15 PM...

Страница 11: ...Battery has a damaged cell Over temperature protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t co...

Страница 12: ...entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods f...