![Kinco CV100 Series Скачать руководство пользователя страница 101](http://html1.mh-extra.com/html/kinco/cv100-series/cv100-series_manual_1967653101.webp)
98
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
0
:
Start from first step
1
:
Start from the step before
stop(or alarm).
2
:
Start from the step and
frequency before stop(or alarm)
Hundred’s place of LED:
Storage after power off
0
:
Disable
1
:
Save the segment,frequency
when power off
Thousand’s place of LED:
Time unit selector for each step
0
:
Second
1
:
Minute
C2.01
Step 1 setting
Unit’s of LED
:
0
:
Multiple frequency
N(N:corresponding to current step)
1
:
Defined by A0.02
2
:
Multiple closed-loop
reference N(N:corresponding to
current step)
3
:
Defined by C1.01
Ten’s place of LED
:
0
:
Forward
1
:
Reverse
2
:
Defined by operation
command
Hundred’s place of LED
:
0
:
Acc/Dec time 1
1
:
Acc/Dec time 2
2
:
Acc/Dec time 3
3
:
Acc/Dec time 4
1
000
○
0~323H
C2.02
Step 1 operating
time
0.0~6500.0
0.1
20.0
○
0~65000