Kinco 3M2280N Скачать руководство пользователя страница 22

User Manual 

2.4 Product Functions Describetion 

3M2280N stepper motor drivers adopt DSP single-chip microcomputer as its control core, 

which  greatly  enriches  their  applications.  Meanwhile,  the  intelligent  firmware  design  frees 

the users from complicated function setting steps and delivers the optimum performance of 

the motors easily. 

 

Motor auto adaptation: 

The driver can automatically detect the electrical parameters 

(e.g.,  inductance  and  resistance)  of  the  motor  connected  with  the  driver,  trace  the 

status  of  motor  in  real  time,  and  automatically  adjust  the  driver  parameters  settings 

according to the detected motor status to deliver the optimum driving performance. If it 

is not the first time for the driver to drive the motor, please run the driver under no load 

before  connecting  the  motor.  Then,  the  driver  will  clear  the  motor  parameters  which 

stored before. Turn off the power, connect the motor, and turn on the power again; the 

driver will automatically detect the optimum drive parameters for the current motor.

 

 

Phase  memory: 

The  driver  will  keep  the  phase  of  the  motor  in  the  case  of  power 

failure  with  the  motor.  Therefore,  it  prevents  the  error  caused  by  motor  jitter  upon 

power-on  on some  application  occasions.  The  kept phase  will  be  lost if  the  motor is 

replaced or the motor still rotates after the driver stops. 

 

 

Half  current  function: 

If  the  half  current  setting  is  effective.  After  the  motor  stops 

rotation and locks tight, the driver will reduce the phase current of the motor by a half 

in 1.5 seconds. Strongly recommended to use this function!!!

 

 

Test running: 

If the driver is set to this status, it will automatically drive the motor at a 

speed of 60RPM. At this time, the output current is the set value and the subdivision 

setting  becomes  invalid.  This  function  is  used  to  check  whether  the  driver  status  is 

normal.

 

 

PLS+DIR and CW/CCW compatible input: 

The control signal input port of the driver 

supports “PLS + DIR” control signal and “CW/CCW” control signal input. 

 

 

Over-voltage alarm: 

The driver will generate a high-voltage alarm if the internal bus 

voltage exceeds 395 VDC. At this time, turn off the power supply in time and reboot 

the  driver  to  clear  the  alarm.  If  the  over-voltage  alarm  occurs  frequently,  it  is 

recommended that the input voltage be tuned down or a driver with absorption function 

be adopted.

 

 

Short circuit alarm: 

The driver will activate the short circuit protection function in the 

case  of  short-circuit  or  wrong  wiring  of  the  motor  or  driver,  so  as  to  prevent  the 

damage  to  the  driver.  In  this  case,  turn  off  the  power  supply  in  time  and  check  the 

wiring of the motor. To clear the alarm, reboot the driver. 

 

 

Under-voltage alarm: 

The driver will generate a low-voltage alarm if the internal bus 

voltage goes below 200 VDC in the case of the

 

2M2280N driver or 90VDC in the case 

Содержание 3M2280N

Страница 1: ...Kinco N 3M2280N V1 2...

Страница 2: ......

Страница 3: ...3M2280N 1 2 3 2 1 3 2 2 3 2 3 3 2 4 3 2 5 4 2 6 4 5 3 1 5 3 2 5 3 3 7 3 4 8 3 5 9 3 6 11 12 4 1 12 4 2 12 N 3M2280N V1 2 2013 11 08 V1 0 2010 8 5 V1 1 2011 10 13 V1 2 2013 11 08...

Страница 4: ...2 3M2280N 310VDC 60 1 25...

Страница 5: ...3M2280N 3 2 1 3M2280N 1 1 1 1 2k 3 10mm 10 3 15mm 12 3 2 2 2 3 N DSP 2 4 3M2280N 187V 253V 220V ERR 1 5S...

Страница 6: ...4 400KHZ 14 2 5 3M2280N DSP 1 5 25 60RPM PLS DIR CW CCW 3M2280N 395VDC 3M2280N 200VDC 75 2 6 KINCO 110 130...

Страница 7: ...87VAC 253VAC 2 8 3 2 3 6 4 0 4 4 4 8 5 2 5 6 6 6 4 6 8 7 2 7 6 8 0 A 400 20000pulse rev 14 110 130 PLS CW DIR CCW FRE 6 16 mA PLS DIR CW CCW ERR 1 5s 50 2 85 RH 0 40 20 70 1 5Kg 201mm 147mm 66mm IP20...

Страница 8: ...6 DIR CCW 1 25uS 400KHz FREE FREE ERR 30VDC 10mA ERR 4 U U V W V W NC R R 5 L 3M2280N 220V N PE...

Страница 9: ...3M2280N 7 3 3 R0 24VDC 2K 12VDC 1K 6 16mA ERR OC 30V ERR...

Страница 10: ...8 3 4 400KHz 1ms 10 1 5mm2 10mm...

Страница 11: ...6000 10000 20000 SET1 SET2 S2 Current S2 0 1 2 3 4 5 6 7 Peak A 2 80 3 20 3 60 4 00 4 40 4 80 5 20 5 60 Rms A 1 98 2 26 2 55 2 83 3 11 3 39 3 68 3 96 S2 8 9 A B C D E F Peak A 6 00 6 40 6 80 7 20 7 60...

Страница 12: ...10 2 PLS DIR...

Страница 13: ...3M2280N 11 3 6 50mm IP20...

Страница 14: ...12 4 1 N Power Run Error Chop 0 5Hz 5Hz ERR 4 2 1 130 80 90 2 P 2 n 60 A B C...

Страница 15: ...Kinco Electric Shenzhen Ltd 6 518057 86 755 26585555 86 755 26616372 http www kinco cn Email sales kinco cn...

Страница 16: ......

Страница 17: ...Kinco N Series Stepper Motor Driver 3M2280N User Manual Version V1 0...

Страница 18: ......

Страница 19: ...of Wiring Terminal 6 3 3 Wiring Diagram 8 3 4 Time Sequence Diagram of Control Signal 10 3 5 DIP Switch Settings 11 3 6 Installation of the Driver 13 Chapter 4 FAQ 14 4 1 Indications of Driver Indica...

Страница 20: ...related technical specifications and electric installation standards during installation The driver must be securely grounded with the cross section of the ground cable not less than 1 25 mm 2 Do not...

Страница 21: ...1 pcs 2k resistors 3 pcs Length 10mm diameter 10 insulated terminals 3 pcs Length 15mm diameter 12 insulated terminals 3 pcs 2 2 Product Model Description 2 3 Product Features High performance low cos...

Страница 22: ...s after the driver stops Half current function If the half current setting is effective After the motor stops rotation and locks tight the driver will reduce the phase current of the motor by a half i...

Страница 23: ...river and the motor is wrong To clear the alarm reconnect the wires correctly 2 5 Scope of Application The drivers are applicable to various large and medium automation equipment and instruments inclu...

Страница 24: ...customize used to absorb the energy feed back by the motor Table 2 Operating Environment Cooling method Forced air cooling Environment Operation environment Avoid the environment with great amount of...

Страница 25: ...time in this mode shall not be less than 1 25uS The maximum input frequency of the pulse signal is 400 KHz DIR CCW FREE This signal is offline signal If the signal is at a high level the driver turns...

Страница 26: ...User Manual 8 3 3 Wiring Diagram General Way Control Signal Wiring Diagram Twisted pair Way Control Signal Wiring Diagram...

Страница 27: ...when the control signal is at 12VDC a 1K resistor can be connected The current at the input port of the driver must be within 6 16 mA otherwise it may cause damage to the equipment ERR signal is open...

Страница 28: ...ground of the driver and equipment 3 Due to endurance of heavy current conductors with cross section no less than 1 5mm 2 are recommended for the motor cabling or even thicker ones as appropriate Mot...

Страница 29: ...0 D when driver is power off then power on the driver the motor will run automatically PLS DIR E E Set S1 and S2 as the MODE settings as the left table when driver is power off then power on the driv...

Страница 30: ...unction setting flow Drive power off Driver power on S1 E S2 E F C D Setting success Driver work in setting mode Reboot the driver RUN SLINK POWER GREEN ERR RED CHOP OFF Drive power off RUN SLINK POWE...

Страница 31: ...ossible frequent overheat alarms For better heat dissipation two drivers shall be installed at a clearance of at least 50mm 1 With an ingress protection class of IP20 the driver shall be installed in...

Страница 32: ...to phase error On Off On Blink quickly The motor power supply disconnects and the motor shaft releases Over current alarm On Off Blink quickly Off The motor power supply disconnects and the motor shaf...

Страница 33: ...lt cause lower torque or out of step of the motor Therefore the maximum allowable surface temperature of a stepper motor depends on the demagnetization point of different magnetic materials In general...

Страница 34: ...Shenzhen Ltd Address Building 1 No 6 Langshan 1st Rd Hi tech Park North Nanshan Shenzhen China 518057 Tel 86 755 2658555 Fax 86 755 26616372 http www kinco cn Email sales kinco cn To be the partner o...