Remove the front part at the back of the device.
➢
Change the old batteries by AAA LR03 1.5V batteries.
➢
Replace the front.
CHANGE THE BATTERIES
The device is on.
➢
Press on «
Backlight
» : to activate the device backlight.
➢
Press again on this key to deactivate the backlight.
ACTIVATE THE BACKLIGHT
Adjust the atmospheric pressure :
To have a precise and representative measurement,
the atmospheric pressure of the location where are performed the measurements must
be entered in the device. The atmospheric pressure must be between 800 and 1200 hPa.
The device is on and displays the measurement.
➢
Press on «
Select
» until «
P_ATM
» blinks on screen.
➢
Press on «
OK
».
The first digit of the atmospheric pressure blinks.
➢
Press on «
Select
» to select its value.
➢
Press on «
OK
» to validate and pass to the following digit, perform the same procedure for the following digits (press on
«
On/Off/Esc
»
to return to the previous digit).
➢
When the first digit is adjusted, press on «
OK
» to validate.
«
P
_
ATM
» blinks on screen.
➢
Press on «
On/Off/Esc
» to return to the measurement display.
Adjust the temperature :
To have a precise and representative measurement, the temperature of the location where are performed the measurements must be
entered in the device. The temperature must be between -20 and +80°C.
The device is on and displays the measurement.
➢
Press on «
Select
» until «
TEMP
» blinks on screen.
➢
Press on «
OK
».
The first digit blinks.
➢
Press on «
Select
» to select the temperature sign :
-
for a negative temperature and 0 for a positive temperature.
➢
Press on «
OK
» to validate and pass to the following digit.
➢
Press on «
Select
» to select the value of this second digit and press on «
OK
» to validate, perform the same procedure for the
following digit (press on
«
On/Off/Esc
», to return to the previous digit).
➢
When the last digit is adjusted, press on «
OK
» to validate.
«
TEMP
» blinks on screen.
➢
Press on «
On/Off/Esc
» to return to the measurement display.
Adjust the coefficient :
This coefficient corresponds to the coefficient of the differential pressure element used to measure the velocity (Pitot L tube(coeff : 1.0015)
or S (coeff : 0.84), Debimo blades...).
The device is on and displays the measurement.
➢
Press on «
Select
» until «
COEF
» blinks on screen.
➢
Press on «
OK
».
The first digit blinks.
➢
Press on «
Select
» to select the first digit value and press on «
OK
» to validate, performs the same procedure for the following digits
(press on «
On/Off/Esc
», to return to the previous digit).
➢
When the first digit is adjusted, press on «
OK
» to validate.
«
COEF
» blinks on screen.
➢
Press on «
On/Off/Esc
» to return to the measurement.
Once returned to KIMO, required waste collection will be assured in the respect of the environment in accordance to 2002/96/CE guidelines relating to WEEE
N
Ta
ng
–
p
or
ta
bl
e-
M
P1
20
–
1
0/
06
/1
4
–
R
C
S
(2
4)
P
ér
ig
ue
ux
3
49
2
82
0
95
N
on
-c
on
tra
ct
ua
l d
oc
um
en
t –
W
e
re
se
rv
e
th
e
rig
ht
to
m
od
ify
th
e
ch
ar
ac
te
ris
tic
s
of
o
ur
p
ro
du
ct
s
w
ith
ou
t p
rio
r n
ot
ic
e.