8 Accessories

Accessories

References

Illustrations

1 double AA lithium 3.6 V battery

          2 batteries are required for class 320 
dataloggers

KBL-AA

Safety lock wall mount with padlock

KAV-320

Wired extension for class 320 KISTOCK probes

In polyurethane, 5 m length with male and female mini-DIN 

connectors
Note: several extensions can be wired in order to obtain up to 

25 m cable length

KRB-320

Configuration and data processing software

KILOG software allows to configure, save and process your data
in a very simple way.

Software only: KILOG-3-N

Complete set (so 1

USB cable): KIC-3-N

Data collector

Collects up to 20 000 000 points from one or several KISTOCK 

directly on-site. Results restitution on PC of realised datasets

KNT-320

USB micro-USB

 

cable 

which allows to plug your KISTOCK 

datalogger to your PC

CK-50

Neck size hand strap

KDC

Only the accessories supplied with the device must be used. 

9 Troubleshooting

Problem

Probable cause and possible solution

No value is displayed, only the icons are present.

The display is configured on “OFF”. Configure it on “ON” with 
the KILOG software (see page 16).

The display is completely off* and there is no 

communication with the computer.

The battery has to be replaced. (see page 17).

The display indicates 

“- - - -”

 instead of the measured 

value.

The probe is disconnected. Plug it again to the datalogger.

There is no Bluetooth communication with the 
datalogger.

The Bluetooth activation is on OFF. Reconfigure Bluetooth on ON 
with the KILOG software (see page 16).

* Only with the KT 320 and KTT 320 KISTOCK.

Troubleshooting

19

Содержание KISTOCK 320 Series

Страница 1: ...Class 320 KISTOCK KT 320 KCC 320 KP 320 321 KPA 320 KTT 320 USER MANUAL...

Страница 2: ......

Страница 3: ...bes 10 3 6 Dimensions in mm 11 3 6 1 Devices 11 3 6 2 Wall mount in option 11 3 7 Guarantee period 11 4 Use of the device 12 4 1 Display 12 4 2 Function of LEDs 12 4 3 Function of keys 13 4 3 1 Groups...

Страница 4: ...se the protection ensured by the device 1 2 Symbols used For your safety and in order to avoid any damage of the device please follow the procedure described in this user manual and read carefully the...

Страница 5: ...dataloggers are ideal for different parameters surveillance temperature hygrometry light current voltage impulsion relative pressure They ensure the traceability in the food industry environment as w...

Страница 6: ...the device and the computer is carried out via an USB cable and with the female micro USB connector 2 8 Mounting The class 320 KISTOCK has magnetic mountings so you can fix it easily 6 Presentation of...

Страница 7: ...C 0 3 of the reading 0 4 C below 0 C S 0 6 C Setpoints alarm 2 setpoint alarms on each channel Frequency of measurements From 1 second to 24 hours Operating temperature From 40 to 70 C From 20 to 70 C...

Страница 8: ...0 to 50 C 0 8 C below 0 C or above 50 C Humidity 2 RH from 5 to 95 15 to 25 C Atm pressure 3 hPa CO2 50 ppm 3 of the reading Temperature 0 4 C from 0 to 50 C 0 8 C below 0 C or above 50 C Humidity 2...

Страница 9: ...mmed units The available programmed units for the KT 320 and KTT 320 KISTOCK are the following m s fpm m s C F HR K PSI Pa mmH2O inWg kPa mmHg mbar g Kg bar hPa daPa Ctd Ftd Ctw Ftw kj kg mA A mV V Hz...

Страница 10: ...Voltage input cable 0 5 V or 0 10 V KICC Current input cable 0 20 mA or 4 20 mA KICI Pulse input cable Maximal voltage 5 V Type of input TTL frequency counting Maximal frequency 10 kHz Maximum number...

Страница 11: ...e mark on the probe is in front of the user 3 6 Dimensions in mm 3 6 1 Devices 3 6 2 Wall mount in option 3 7 Guarantee period KISTOCK dataloggers have 1 year guarantee for any manufacturing defect re...

Страница 12: ...15 seconds at least one threshold has been exceeded during the dataset Operating LED If the green ON LED has been activated it flashes every 10 seconds during the recording period DATASET is finished...

Страница 13: ...ated Illustration Waiting for start flashes Start by button Stop indifferent Start of dataset Inactive Start by PC date time Stop indifferent Inactive Start indifferent Stop indifferent Measurements s...

Страница 14: ...erated Illustration Start indifferent Stop indifferent Group scrolling groups 1 2 and 3 Dataset finished Indifferent Inactive Indifferent Measurements scroll Please see the summary table of the groups...

Страница 15: ...be 1 Min value in Parameter 1 of probe 1 High alarm threshold in Parameter 1 of probe 1 Low alarm threshold in Parameter 1 of probe 1 Parameter 2 of probe 1 Max value in Parameter 2 of probe 1 Min val...

Страница 16: ...onnector of the cable to an USB connection on your computer 2 Open the USB cap on the right side of the datalogger 3 Connect the male micro USB connector of the cable to the female micro USB connector...

Страница 17: ...place the battery hatch and screw it Only use trademark or high quality batteries in order to guarantee the announced autonomy After the battery replacement the device must be reconfigured 6 2 Device...

Страница 18: ...e KCC 320 device with the supplied Tygon tube Generate a gas flow of 30 l h Wait for the measurement stabilisation about 2 minutes Check the CO2 values measured by the KCC 320 If these values are not...

Страница 19: ...te Results restitution on PC of realised datasets KNT 320 USB micro USB cable which allows to plug your KISTOCK datalogger to your PC CK 50 Neck size hand strap KDC Only the accessories supplied with...

Страница 20: ...rdance to guidelines relating to WEEE BE CAREFUL Material damages can happen so please apply the precautionary measures indicated NTang Class 320 Kistock 19 11 18 RCS 24 P rigueux 349 282 095 Non cont...

Отзывы: