MAINTENANCE INSTRUCTIONS:

Make certain electricity is 

OFF 

before

beginning maintenance procedures.

Reflector and Lens Cleaning:

A regularly scheduled maintenance
program should be established to 
retain light output and minimize heat
retention.  Dusting with a clean, dry 
cloth is normally sufficient for the 
reflector.  Dust or dirt film accumulation
should be regularly removed from both
sides of the lens by washing with 
ammonia and water.  

DO NOT

use strong alkaline, acid, or

abrasive cleaners.

Page 2              Kim Lighting • 16555 E. Gale Ave. • P.O. Box 60080 • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-3861

Side View

AFL31

Horizontal Flood

AFL32

Vertical Flood

AFL33

Medium Flood

AFL30  Architectural Floodlight

Installation Instructions

FIXTURE ADJUSTMENT:

1.  Holding fixture so it will not fall, loosen

two trunnion bolts with

L

L

” 

socket and

ratchet.

2. Adjust fixture to desired angle and

tighten trunnion bolts with 25 (mini-
mum) to 30 foot pounds of torque.
Secure fixture angle by tightening (4)

C

C

-16 Socket Set Point Screws.

TRUNNION MOUNTING DETAIL

30°

15°

E

” Dia.

3” Dia.

N

” Dia. Mounting Holes

15

K

7

L

18

L

” R.

KIM LIGHTING

20”

15”

5

L

Note:

Lamp position changes
with reflector type.

Remote outlet

or Junction Box

(by others)

(2) 

K

-16 Hex Hd.

Trunnion Bolt 

(

Socket & Torque

Wrench)

(4)

C

-16 

Socket Set Screws 
(

F

” Allen Wrench)

Locate Outlet

Within 5 Ft.  

Of Fixture

Provide Drip-
Loop In Cord

Bottom View

3

K

5

H

10”

Wall Mounted Aiming Warning:

Due to the risk of fire, do not aim 

fixture directly towards the wall.

!

!

AFL34

Narrow Flood

AFL35

Spot

AFL36

Narrow Spot

Lamp Information

Fixture

Lamp Type

Wattage

AFL30

HPS

750

MH

750 - 1000

Make certain electrical supply is 

OFF

before starting fixture installation.

1. Install fixture within 5 ft. of outlet or junction box.  (All AFL30 fixtures are equipped with a 6ft. long #16-3 Type

S00W-A cord.)  Attach fixture cord to circuit leads observing polarity, i.e., green-to-ground, white-to-common, and
black-to-voltage.  Cord should have a drip-loop between junction box and fixture (see below).  Allow enough length
in cord to make fixture aiming adjustments.

2. Open lens frame and install lamp of type and wattage shown on fixture label and chart on page 3.  All lamps must

be rated for “Universal Burning Position” because fixture tilt changes lamp orientation.  Check that fixture gasket is
in place and close lens frame by applying left pressure to seat frame against hinges before closing.  Tighten screws
progressively and evenly to a hand-snug condition with allen wrench.

!

WARNING!

The H.I.D. / Fluorescent fixture utilizes a lamp that may

contain mercury.  For information on disposal of lamp, go to

website:  

www.lamprecycle.org

NOTE:  Kim Lighting assumes no responsibility for fixture mountings designed by others.

!