MAINTENANCE INSTRUCTIONS:
Make certain electricity is
OFF
before
beginning maintenance procedures.
Reflector and Lens Cleaning:
A regularly scheduled maintenance
program should be established to
retain light output and minimize heat
retention. Dusting with a clean, dry
cloth is normally sufficient for the
reflector. Dust or dirt film accumulation
should be regularly removed from both
sides of the lens by washing with
ammonia and water.
DO NOT
use strong alkaline, acid, or
abrasive cleaners.
Page 2 Kim Lighting • 16555 E. Gale Ave. • P.O. Box 60080 • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-3861
Side View
AFL31
Horizontal Flood
AFL32
Vertical Flood
AFL33
Medium Flood
AFL30 Architectural Floodlight
Installation Instructions
FIXTURE ADJUSTMENT:
1. Holding fixture so it will not fall, loosen
two trunnion bolts with
L
L
”
socket and
ratchet.
2. Adjust fixture to desired angle and
tighten trunnion bolts with 25 (mini-
mum) to 30 foot pounds of torque.
Secure fixture angle by tightening (4)
C
C
-16 Socket Set Point Screws.
TRUNNION MOUNTING DETAIL
30°
15°
E
” Dia.
3” Dia.
N
” Dia. Mounting Holes
15
K
”
7
L
”
18
L
” R.
KIM LIGHTING
20”
15”
5
L
”
Note:
Lamp position changes
with reflector type.
Remote outlet
or Junction Box
(by others)
(2)
K
-16 Hex Hd.
Trunnion Bolt
(
L
Socket & Torque
Wrench)
(4)
C
-16
Socket Set Screws
(
F
” Allen Wrench)
Locate Outlet
Within 5 Ft.
Of Fixture
Provide Drip-
Loop In Cord
Bottom View
3
K
”
5
H
”
10”
Wall Mounted Aiming Warning:
Due to the risk of fire, do not aim
fixture directly towards the wall.
!
!
AFL34
Narrow Flood
AFL35
Spot
AFL36
Narrow Spot
Lamp Information
Fixture
Lamp Type
Wattage
AFL30
HPS
750
MH
750 - 1000
Make certain electrical supply is
OFF
before starting fixture installation.
1. Install fixture within 5 ft. of outlet or junction box. (All AFL30 fixtures are equipped with a 6ft. long #16-3 Type
S00W-A cord.) Attach fixture cord to circuit leads observing polarity, i.e., green-to-ground, white-to-common, and
black-to-voltage. Cord should have a drip-loop between junction box and fixture (see below). Allow enough length
in cord to make fixture aiming adjustments.
2. Open lens frame and install lamp of type and wattage shown on fixture label and chart on page 3. All lamps must
be rated for “Universal Burning Position” because fixture tilt changes lamp orientation. Check that fixture gasket is
in place and close lens frame by applying left pressure to seat frame against hinges before closing. Tighten screws
progressively and evenly to a hand-snug condition with allen wrench.
!
WARNING!
The H.I.D. / Fluorescent fixture utilizes a lamp that may
contain mercury. For information on disposal of lamp, go to
website:
www.lamprecycle.org
NOTE: Kim Lighting assumes no responsibility for fixture mountings designed by others.
!