background image

 

 

   

OPERATION AND MAINTENANCE MANUAL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    DC-TYPE Automatic Non Carbon-Brush Series         

KILEWS INDUSTRIAL CO., LTD.

 

http://www.kilews.com 

 

Y2F184A-1-007 

Power source 
on the top 

 

Power source 
on the bottom 
                                             

SKD-TBK20L-D 

SKD-TBK30L-D 

SKD-TBK50L-D 

SKD-TBK70L-D 

SKD-TBK30LF-D 

SKD-TBK35LF-D 

SKD-TBK50LF-D 

 

 

SKD-TBK20L-U 

SKD-TBK30L-U 

SKD-TBK50L-U 

SKD-TBK70L-U 

SKD-TBK30LF-U 

SKD-TBK35LF-U 

SKD-TBK50LF-U 

 

Содержание SKD-TBK20L-D

Страница 1: ...STRIAL CO LTD http www kilews com Y2F184A 1 007 Power source on the top Power source on the bottom SKD TBK20L D SKD TBK30L D SKD TBK50L D SKD TBK70L D SKD TBK30LF D SKD TBK35LF D SKD TBK50LF D SKD TBK...

Страница 2: ...on enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manu...

Страница 3: ...ing and use common sense when operating a power tool Do not use power tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools...

Страница 4: ...maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tools accessories and tool bits etc in accordance with these instructions and in the...

Страница 5: ...cord to connect to cable 3 Bit Ssleeve For Hex Fixed Bit Use 4 Torque Adjusting Ring Adjust torque Use 5 Coupler Fixed upside underside housing and clutch Use 6 Trigger switch when the trigger switch...

Страница 6: ...and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm To...

Страница 7: ...witch to Reverse If the screw is reversed thread screw please set Forward Reverse switch to Forward Follow the above operation after loosening the screw release the trigger to stop Push Start Type scr...

Страница 8: ...the switch to Lo for slowest rotation It s possible that the uncompleted shut off occurs when the switch is setup to Lo and the presetting torque is more than 50 of torque range Please refer to the f...

Страница 9: ...center 3 KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted 4 Repairs should by made only by authorized trained personnel Consult your nea...

Страница 10: ...K30L TBK50L TBK30LF TBK35LF TBK50LF TBK70L Input voltage DC DC 40V Power Consumption 50 Torque N m Hard Joint 0 3 2 0 8 3 2 5 1 0 3 0 1 2 3 5 2 5 2 5 7 Soft Joint 0 3 1 6 0 8 2 4 2 4 1 0 2 4 1 2 2 8 2...

Страница 11: ...rque of screw itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque checker values perform the torque control properly 1 Please read...

Отзывы: