background image

 
                                                                                                                                                           

 

                   

 

                           

 

 

 
 

 

  1

This tool should be grounded while in use to protect the operator from electric shock. NOTICE ! To ensure the 

grounding result, the grounding conductor of the power cord must be well connected with the grounding terminal of 
power facility. This tool is equipped with grounding conductors. The Green(or Green and Yellow)conductor in the 
Power Cord is the grounding wire. Never connect Green (or Green and Yellow) to a live terminal. The grounding wires 
in this tool can not only earth the electric leakage safely, but also can eliminate ESD-the electrostatic that tool occurred 
while in use. 

2

The grounding is the most important task a user. Periodically, depends on the working condition and circumstance, for 

maintaining a good function the user has to check the grounding condition every 3~6 months by an electric meter and 
following simple step

s; Set the Ohm meter to level R*100(Ohm). Touching 2 test rods (“

”) together and reset 

the meter to “0”. Using the Red(“

”) rod to touch the Grounding wire on the Plug of controller’s cord, and the 

Black(“

”) rod to the end of Bit Head. It stands for the grounding is normal if the meter is read as close as to “0”. For 

getting a normal indication on the meter while in testing, need to press the test rods firmly to the testing objects. 

3

The instrument QC of the tool is performed before the tool ex-factory. The grounding continuity test is conducted by 

input 26A voltage to the end of earth terminal, and subject to the resistance value lower than 0.3Ohm. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING

 

DO NOT OPERATE THIS TOOL WITHOUT 

PROTECTIVE EARTH CONNECTED 

 
 
 
 
 

                  Grounding Instructions 

Содержание SKD-TBK20L-D

Страница 1: ...STRIAL CO LTD http www kilews com Y2F184A 1 007 Power source on the top Power source on the bottom SKD TBK20L D SKD TBK30L D SKD TBK50L D SKD TBK70L D SKD TBK30LF D SKD TBK35LF D SKD TBK50LF D SKD TBK...

Страница 2: ...on enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manu...

Страница 3: ...ing and use common sense when operating a power tool Do not use power tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools...

Страница 4: ...maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tools accessories and tool bits etc in accordance with these instructions and in the...

Страница 5: ...cord to connect to cable 3 Bit Ssleeve For Hex Fixed Bit Use 4 Torque Adjusting Ring Adjust torque Use 5 Coupler Fixed upside underside housing and clutch Use 6 Trigger switch when the trigger switch...

Страница 6: ...and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm To...

Страница 7: ...witch to Reverse If the screw is reversed thread screw please set Forward Reverse switch to Forward Follow the above operation after loosening the screw release the trigger to stop Push Start Type scr...

Страница 8: ...the switch to Lo for slowest rotation It s possible that the uncompleted shut off occurs when the switch is setup to Lo and the presetting torque is more than 50 of torque range Please refer to the f...

Страница 9: ...center 3 KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted 4 Repairs should by made only by authorized trained personnel Consult your nea...

Страница 10: ...K30L TBK50L TBK30LF TBK35LF TBK50LF TBK70L Input voltage DC DC 40V Power Consumption 50 Torque N m Hard Joint 0 3 2 0 8 3 2 5 1 0 3 0 1 2 3 5 2 5 2 5 7 Soft Joint 0 3 1 6 0 8 2 4 2 4 1 0 2 4 1 2 2 8 2...

Страница 11: ...rque of screw itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque checker values perform the torque control properly 1 Please read...

Отзывы: