Store idle power tools out of reach of children and do not allow persons unfamiliar with the power tool or these 

instructions to operate the power tool.   

Power tools are dangerous in the hands of untrained users. 

Do not let visitors touch the tool or extension cord. All visitors should be kept away from work area. 

e) 

Maintain power tools. Check for misalignment or binding of moving parts, breakage of parts and any other 

condition that may affect the power tools operation. If damaged, have the power tool repaired before use.

 

Many accidents are cause by poorly maintained power tools.   

Inspect extension cords periodically and replace, if damaged. 

f) 

Keep cutting tools sharp and clean

,   

Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control. 

g) 

Use the power tools, accessories and tool bits ect., in accordance with these instructions and in the manner 

intended for the particular type of power tool, taking into account the working conditions and the work to be 

performed.   

Use of the power tool for operations different from intended could result in a hazardous situation. 

5) SERVICE 

a) Have your power tool serviced by qualified repair person using only indentical replacement parts, This will ensure that 

the safety of the power tool is maintained. 

Additional information shall be provide 

a)  Instruction for putting into use 

1.  Setting-up or fixing power tool in a stable position as appropriate for power tools which can be mounted on a support. 
2.  Assembly 
3.  Connection to power supply, cabling, fusing, socket type and earthing requirements. 
4.  Illustrated description of functions. 
5.  Limitations on ambient conditions. 
6.  List of contents. 

b)  Operating Instructions. 

1.  Setting and testing.                                                      2. Tool changing. 
3. Clamping of work.                                                   

   

4. Limits on size of work piece. 

5. General instructions for use. 

c)  Maintenance and servicing. 

1.  Regular cleaning, maintenance, and lubrication. 
2.  Servicing by manufacture or agent, list of addresses. 
3.  List of user-replaceable parts. 

4. 

Special tools which may be required

6) 

Clamp fixed position for 3cm Nylon Fixed-Wire   

The clamp fixed position for 3cm Nylon Fixed-Wire is at 235mm start count from the top of the screwdriver flat 

surface (for direct cable), as shown in Figure 1. 

The clamp fixed position for 3cm Nylon Fixed-Wire is at 285mm start count from the top of the screwdriver flat 

surface( for 15 cm tail cable), as shown in Figure 2. 

The clamp fixed position for 3cm Nylon Fixed-Wire is at 390mm start count from the top of the screwdriver flat 

surface (for Iron ring socket type), as shown in Figure 3. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SKD-BN512L

Страница 1: ...MAINTENANCE MANUAL DC TYPE Automatic Non Carbon Brush Series KILEWS INDUSTRIAL CO LTD http www kilews com Y2F118A 1 003 SKD BN512L SKD BN519L SKD BN512LF SKD BN517LF SKD BN512P SKD BN519P SKD BN512PF...

Страница 2: ...on enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manu...

Страница 3: ...while operating power tools may result in serious personal injury b Use safety equipment Always wear eye protection Safety equipment such as dust mask non skid safety shoes hard hat or hearing protect...

Страница 4: ...ir person using only indentical replacement parts This will ensure that the safety of the power tool is maintained Additional information shall be provide a Instruction for putting into use 1 Setting...

Страница 5: ...and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm To...

Страница 6: ...ewdriver 9 Don t touch For Rew Switch during operating for keeping system from wrong judgement 10 Use cable for the external counter and I O box is shield cable for avoidance of electrical interferenc...

Страница 7: ...l by releasing the lever to the original position or releasing the bit From the screw head To return the screw set the changeover switch to R position Maintenance and Inspection 1 The screw driver mus...

Страница 8: ...center 3 KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted 4 Repairs should by made only by authorized trained personnel Consult your nea...

Страница 9: ...Tapping screw 1 6 2 6 2 3 3 0 1 6 2 6 1 6 2 6 1 6 2 6 2 3 3 0 1 6 2 6 1 6 2 6 Weight g 520 Length mm 245 Model of Torque Fixing Ring KC 6C KC 6S Power controller SKP 32B 60W BN6PIN SKP BE32HL BN6PIN S...

Страница 10: ...s standard to obtain an appropriate clamping torque 6 The Return torque method in which once clamped screw is returned with torque wrench or the like is available as one of torque control methods howe...