background image

                                                                   

BN Series

 

 

3.2 LED Display in setting mode and error code description : 

Symbol 

Definition 

Description

 

 

Set Slow Start Time 

1.  Press 

  for 2 Sec, LED will display 

[RC]

 

2.  Use 

 or 

  to increase or descrease slow start time 

value from 0.0 to 9.9 sec 

 

Set Slow Start 

Speed 

Level 

1.  Press 

+

  for 1 sec after set 

[RC]

, LED will display 

[SP]

 

2.  Use 

or

  to increase or descrease slow start speed level 

from L0 (100%, Disable) or L1 to L9 (30%~90%) 

 

Slow Start 

Speed Level 

1.  When 

[SP] 

set to

 [L1] ~ [L9]

, indicate the slow start speed 

level. 

 

No Slow Start 

Function 

1.  When [SP] set to [L0] , disable slow start function   

 

Under Voltage 

Protection 

1.  Screwdriver will stop when the operation voltage is lower. 

2.  LED will display 

[E3]

 to indicate Over voltage protection. 

3.  Screwdriver will disable 10 sec then automaic recovery 

 

Over Temp. 

Protection 

1.  Screwdriver will stop when the operation temperature is 

higher. 

2.  LED will display 

[E4]

 to indicate Over temperature 

protection. 

3.  Screwdriver will disable 10 sec then automaic recovery 

 

Stall Protection 

1.  Screwdriver will stop when motor is abnormal stalled after 

start. 

2.  LED will display 

[E5]

 to indicate stall protection. 

3.  Screwdriver will disable 10 sec then automaic recovery 

 

Push plate Error 

1.  Screwdriver will stop when push plate change between 

motor running. 

2.  LED will display 

[E7]

 to indicate abnormal operation. 

3.  Switch push plate back to recovery 

 

Brake Error 

1.  Screwdriver will stop when the abnormal brake signal 

appeared before start. 

2.  LED will display 

[E8]

 to indicate abnormal brake error. 

3.  Check and fix the brake mechanism to recovery 

 

Memory Error 

1.  Screwdriver will stop when the internal flash memory fail. 

2.  LED will display 

[E9]

 to indicate internal flash memory 

error. 

3.  Screwdriver will disable 10 sec then automaic recovery 

 

Содержание BC6P

Страница 1: ...Screwdriver Slow Start Control Box User Operation Manual Model KL SSBN BC6P DC6P Ver 1 0 KILEWS INDUSTRIAL CO LTD http www kilews com Y2F124 5 006 ...

Страница 2: ......

Страница 3: ...n of Kilews Industrial Co Ltd Information provided in this manual is intended to be accurate and reliable However Kilews Industrial Co Ltd Assumes no responsibility for its use nor for any infringements upon the rights of third parties whitch may result from this use Acknowledgements KL SSBN BC6P DC6P is a trademark of Kilews Industrial Co Ltd BN is a series brushless screwdriver model with new co...

Страница 4: ...nication interface KL SSBN BC6P DC6P provide slow start function to improve screw tightening quality under manual operation KL SSBN BC6P DC6P provide three digital output lines to output start brake and reverse signals to external device All output signals use MOSFET relay output to support mostly PLC interface KL SSBN BC6P DC6P is the best choice for screwdrivers apply to integrate with PLC in au...

Страница 5: ...r supply model 4 KL SSBN BC6P DC6P support another alternative KILEWS standard anti EMI cable 3M to connect to BN series screwdriver it can reduce electromaganetic interference 5 Please connect KL SSBN BC6P DC6P to screwdriver then connect to power supply 6 KL SSBN BC6P DC6P is designed to operation only with the KILEWS BN BC6P series brushless screwdriver If connect to the old BC series brushless...

Страница 6: ... COM Pin 4 3 When screwdriver run reversed output signal to Pin 3 and COM Pin 4 2 3 Pin assignment description Pin No Function I O Loop Interface 1 Start Output Output MOS Relay 2 Brake Output Output MOS Relay 3 Reverse Output Output MOS Relay 4 COM Common for output 2 4 Relay output wiring diagrams Regulate the spike voltage generated on the inductive load as follows MOS Relay output circuit max ...

Страница 7: ...ter setting mode LED display RC 2 Press both button for 1 Sec to change to set next function 3 LED display RC SP Exit 4 Screwdriver control will be disabled and the power light will flash each 5 Sec between setting mode 5 Use or button to change the setting value RC Slow start time 0 0 9 9 Sec SP Slow start speed level L0 L9 4 Slow Start Switch 1 Toggle this switch to disable or enable RC SP funct...

Страница 8: ...ry Over Temp Protection 1 Screwdriver will stop when the operation temperature is higher 2 LED will display E4 to indicate Over temperature protection 3 Screwdriver will disable 10 sec then automaic recovery Stall Protection 1 Screwdriver will stop when motor is abnormal stalled after start 2 LED will display E5 to indicate stall protection 3 Screwdriver will disable 10 sec then automaic recovery ...

Страница 9: ...BN Series 7 4 Techical Diagram ...

Страница 10: ...KL SSBN 1 2 3 5 6 8 4 12 7 10 11 14 13 9 ...

Отзывы: