BN Series
5
3. Operation Description :
3.1 Panel setting description :
No.
Function
Description
1
Power / Comm. Error
/ Gate Enable LED
(Green / Blink)
1. Power on and connected display Green light on
2. When disconnect or loss communication with screwdriver , display
Green light and blink every 0.5 sec.
2
▲
(UP)
1. Press
▲
button for 6 sec to reset to factory default values
(RC:0.0
,
SP:L0)
3
▲
(UP) +
▼
(DOWN)
1. Press both
▲
and
▼
button for 2 Sec to enter setting mode, LED
display
[RC]
.
2. Press both button for 1 Sec to change to set next function.
3. LED display
[RC]-[SP]--
Exit.
4. Screwdriver control will be disabled and the power light will flash
each 5 Sec between setting mode.
5. Use
▲
or
▼
button to change the setting value
RC : Slow start time 0.0 ~ 9.9 Sec.
SP : Slow start speed level L0 ~ L9
4
Slow Start
Switch
1. Toggle this switch to disable or enable [RC] [SP] function, LED
display will turn off when function is disabled.
2. If function is enabled, LED will display [NO] , [L1] ~[L9] depends on
the setting status.