4-18
TOS
6200/6210
ON
/
O
FF for Double
A
ction
When DOU
B
LE
A
CT
I
O
N
is se
t
to
O
N,
y
ou
m
u
s
t
p
r
ess
t
he ST
A
RT key wi
t
hin
a
pp
ro
xim
at
ely
a
h
a
lf
-
sec
o
nd
a
f
t
e
r
t
he STO
P
key is p
r
essed
to
s
tart
t
es
t
in
g.
(The
"RE
A
DY" indic
at
i
o
n will
go
out
a
pp
ro
xim
at
ely
a
h
a
lf
-
sec
o
nd
a
f
t
e
r
t
he STO
P
key is
p
r
essed
.
)
Pr
essin
g
t
he SH
I
FT
a
nd F
3
keys
tog
e
t
he
r
a
ll
o
ws y
ou
to
se
t
d
ou
ble
a
c
t
i
o
n
.
Pr
essin
g
t
he SH
I
FT + F
3
keys
togg
les be
t
ween O
N
a
nd OFF se
tt
in
g
s
.
He
r
e
,
a
ppe
ar
s
to
t
he lef
t
o
f DOU
B
LE
A
CT
I
O
N.
When
is displ
a
yed
to
t
he lef
t
o
f DOU
B
LE
A
CT
I
O
N,
y
ou
c
a
n
a
ls
o
u
se
t
he
rotar
y
kn
o
b
to
en
t
e
r
O
N
/OFF se
tt
in
g
s
.
T
ur
nin
g
t
he kn
o
b cl
o
ckwise:
O
N
T
ur
nin
g
t
he kn
o
b c
ou
n
t
e
r
cl
o
ckwise: OFF
ON
/
O
FF for Contact Check
Wi
t
h CO
N
T
A
CT CHECK se
t
to
O
N,
t
he
t
es
t
e
r
c
a
n s
tart
t
es
t
in
g
by m
o
ni
tor
in
g
c
ur-
r
en
t
fl
o
w
t
h
roug
h
t
he OUT
P
UT
t
e
r
min
a
ls
.
When y
ou
p
r
ess
t
he ST
A
RT swi
t
ch wi
t
h
t
he OUT
P
UT
t
e
r
min
a
ls
o
pened
,
a
"TEST"
indic
at
i
o
n
a
ppe
ar
s
o
n
t
he LCD
,
a
nd
t
he TEST LED
o
n
t
he f
ro
n
t
p
a
nel blinks
,
a
nd
t
he
t
es
t
e
r
en
t
e
r
s c
urr
en
t
m
o
ni
tor
in
g
s
tatu
s
.
When
t
he p
ro
be c
o
n
ta
c
t
s
t
he DUT
a
nd
c
au
ses c
urr
en
t
to
fl
o
w
,
t
he TEST LED
o
n
t
he p
a
nel li
g
h
t
s
a
nd
t
he
t
es
t
e
r
be
g
ins
t
es
t-
in
g,
c
o
n
t
in
u
in
g
t
he
t
es
t
u
n
t
il
t
he se
t
t
ime el
a
pses
or
t
he STO
P
swi
t
ch is p
r
essed
.
Pr
essin
g
t
he SH
I
FT
a
nd F4 keys
tog
e
t
he
r
a
ll
o
ws y
ou
to
se
t
t
he c
o
n
ta
c
t
check
.
Pr
ess
-
in
g
t
he SH
I
FT + F4 keys
togg
les be
t
ween O
N
a
nd OFF se
tt
in
g
s
.
He
r
e
,
a
ppe
ar
s
to
t
he lef
t
o
f CO
N
T
A
CT CHECK
.
When
is displ
a
yed
to
t
he lef
t
o
f CO
N
T
A
CT CHECK
,
y
ou
c
a
n
a
ls
o
u
se
t
he
rotar
y
kn
o
b
to
en
t
e
r
O
N
/OFF se
tt
in
g
s
.
T
ur
nin
g
t
he kn
o
b cl
o
ckwise:
O
N
T
ur
nin
g
t
he kn
o
b c
ou
n
t
e
r
cl
o
ckwise: OFF
•
A
fter testing starts, sparking will occur if the probe is separated from the
D
UT
and then recontacts it, potentially damaging the D
UT
or probe.
S
ep-
arate the probe from the D
UT
only after pressing the
STO
P switch.
S
etting the Buzzer Volume
Y
ou
c
a
n se
t
t
he v
o
l
u
me f
or
t
he b
u
zze
r
t
h
at
s
ou
nds in c
a
se
o
f
a
F
AI
L j
u
d
g
men
t
in
t
he
ra
n
g
e f
ro
m
0
to
10
(
r
es
o
l
ut
i
o
n:
1
)
.
The v
o
l
u
me
o
f
t
he b
u
zze
r
f
or
a
PA
SS j
u
d
g
men
t
is
a
pp
ro
xim
at
ely h
a
lf
t
h
at
o
f
a
F
AI
L j
u
d
g
men
t.
1.
I
f B
U
ZZ
ER
V
O
L is not indicated on the L
C
D, press the F4 (
NE
X
T
) or F5
(P
RE
V) function key to display the
SYSTE
M2 screen.
F
or
t
he TOS6
210,
t
he displ
a
y c
a
n
a
ls
o
be swi
t
ched by p
r
essin
g
t
he SH
I
FT
a
nd
keys
tog
e
t
he
r.
C
AUTION
Содержание tos6200
Страница 1: ...Part No Z1 003 302 IB008755 Aug 2011 OPERATION MANUAL EARTH CONTINUITY TESTER TOS6200 TOS6210...
Страница 36: ...3 8 TOS6200 6210...
Страница 130: ...6 52 TOS6200 6210...
Страница 136: ...7 6 TOS6200 6210...
Страница 154: ...A 10 TOS6200 6210...
Страница 157: ...TOS6200 6210 Index I 3 Turning on the power 4 2 U Unpacking 2 2 Upper reference value 4 5 UP LOW 4 30 V VOLT LIMIT 4 33...