126
PLZ-4WH
Troubleshooting
■
Symptom 5:ALARM is activated.
■
Symptom 6:The load cannot be turned on.
Check Item
Possible Cause
Remedy
Location and Status of the Object Check Result
Is the fan stopped?
Yes
Overheat protection tripped.
Immediately stop the use of the instrument
and request repairs.
Is the air intake or outlet
obstructed?
Yes
Overheat protection tripped.
Clogged dust filter
Allow at least 20 cm between the air outlet
and the wall. In addition, do not place
objects within 20 cm.
Clean the dust filter.
Is OCP tripped?
Yes
The OCP setting is small.
Reset the OCP value in the setup screen.
See: "Protection Functions" on page 53
Is OPP tripped?
Yes
The OPP setting is small.
Reset the OPP value in the setup screen.
See: "Protection Functions" on page 53
Check Item
Possible Cause
Remedy
Location and Status of the Object Check Result
A sequence is in operation
Yes
→
Wait for the sequence operation to finish.
Abort the sequence by pressing STOP.
No
The load on/off logic (Load ON
IN) is set to low.
In the menu, select “Configuration” and set
“Load ON INput” to “HIGH.”
See: "Menu" on page 58
Are you using an external
signal to turn the load off?
Yes
→
The load key will be valid after you use an
external signal to turn the load on.
See: "Turning the Load On and Off
through External Control" on page 98
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...