Volt/Thermometer Unit OP02-PFX Specifications
Cell protection function
Cell voltage measurement
Cell overvoltage (overcharge)
protection
Detects overvoltage (overcharge) on the basis of the measured
voltage (A/D-converted value)
Output off
Cell software
OVP
Setting range
0 % to 105 % of the measurable range
Setting
accuracy
1
1
Ambient temperature at 18
°
C
to 28
°
C.
Depends on the voltmeter accuracy
Resolution
1 mV
Activation time
150 ms max.
Cell undervoltage (overdischarge)
protection
Detects undervoltage (overdischarge) on the basis of the measured
voltage (A/D-converted value)
Output off
Cell software
UVP
Setting range
-10 % to 95 % of the measurable range
Setting
accuracy
Depends on the voltmeter accuracy
Resolution
1 mV
Activation time
150 ms max.
Cell overheat protection
Detects the temperature through a thermocouple, output off
Cell OTP
Setting range
-100.0 °C to 400.0 °C
Setting
accuracy
Depends on the temperature measurement (thermistor) accuracy
Resolution
0.1 °C
Cell unbalance protection
Detects the difference between the maximum and minimum cell
voltages
2
, output off
2
The maximum and minimum cell voltages are calculated for the cells in the object under
measurement, and an alarm occurs when the difference between these two values exceeds the set
value.
Setting range
10 mV to 5000 mV
3
3
The voltage difference setting. Voltage difference = Vcell_Max - Vcell_Min
Setting
accuracy
Depends on the voltmeter accuracy
Resolution
1 mV
Activation time
1 s max.
Option communication error
Communication error of Option board, output off
Static
Number of measured terminals
4
Measurement range
1
1
You can apply a voltage from -20 V to 22 V.
-2.0000 V to 20.000 V
Measurement accuracy
2
2
Ambient temperature at 18
°
C
to 28
°
C.
±(0.05 % of r 0.02 % of rating)
Resolution
0.1 mV
Measured value
Average voltage every 100 ms
Measurement interval
100 ms
Содержание PFX2532
Страница 12: ...12 PFX2532 This page is intentionally blank ...
Страница 25: ...Connecting and Configuring Devices This chapter describes how to connect and configure the devices ...
Страница 62: ...62 PFX2532 This page is intentionally blank ...
Страница 71: ...Specifications This chapter provides the PFX2532 s specifications and outline drawing ...
Страница 96: ...96 PFX2532 This page is intentionally blank ...
Страница 141: ......