PFX2000
Setup 1-19
■
When a mixture of PFX2011 and PFX2021 Charge/Discharge
Power Supply Units are installed in a PFX2332 Unit Frame
The example below shows the case when two PFX2021s and three PFX2011s are
installed to the PFX2332. The node numbers for the section where the PFX2021 is
installed are odd numbers only. Therefore, the node numbers are assigned as shown
in Fig. 1-10.
Fig. 1-10
Example When a Mixture of PFX2021s and PFX2011s Are
Installed
1.8
Connecting the TP-BUS
1.8.1
Connecting TP-BUS Cables
The control unit and unit frames (PFX2331 or PFX2332) are connected using the
TP-BUS. The TP-BUS is connected in a chain by connecting twisted-pair cables to
the TP-BUS connectors (plug) provided. Fig. 1-11 shows a TP-BUS connection
example including the impedance measurement unit.
You can connect 12 unit frames and one impedance measurement unit to the control
unit.
• The control unit is a dedicated controller for the PFX2000 Series. You cannot con-
nect Kikusui power supplies (such as the PMR Series) with the TP-BUS interface
and control them.
■
Wires and tools required for connection
1.
Wires
Stranded wire: AWG22 (0.32 mm
2
)
Solid wire: AWG22 (
φ
0.65)
2.
Flat-blade screwdriver
Use the screw driver that comes with the package.
3.
Wire stripper
Wire stripper suitable for the wires described above.
Frame
address
1
PFX2121
Control unit
TP-BUS1
node node node
node
node
node
node
node
01 03 05 06 07
08 09
10
PFX2332 Unit Frame
2 PFX2021 Charge/
Discharge Units
3 PFX2011 Charge/
Discharge Units
NOTE