KIKUSUI Electronics Corp.
118
PROG:EDIT
Collectively sets a sequence step (frequency, voltage, signal change, step time,
waveform bank, status output, trigger I/O, output).
Command
PROGram:EDIT <step_NRf>,<freq-ramp_boolean>,<freq_numer-
ic>,<acv-ramp_boolean>,<acv_numeric>,<dcv-ramp_boolean>,<dcv_nu-
meric>,<time_numeric>,<bank_NRf>,<status-out_boolean>,<trig-out_
boolean>,<trig-in_boolean>,<output_boolean>
PROGram:EDIT? <step_NRf>
Parameter
<step_NRf>
Value: 0 to 599 Number of the step that you want to configure
Parameter
<freq-ramp_boolean>
Value:
ON(1)
Enables the ramped frequency signal change
OFF(0) Disables the ramped frequency signal change (default)
Parameter
<freq_numeric>
Value:
1 to 5000
Frequency (The default value is 50)
Unit:
HZ
Parameter
<acv-ramp_boolean>
Value:
ON(1)
Enables the ramped AC voltage signal change
OFF(0) Disables the ramped AC voltage signal change (default)
Parameter
<acv_numeric>
Value:
0 to 315.0
AC voltage (The default value is 0)
Unit:
V
Parameter
<dcv-ramp_boolean>
Value:
ON(1)
Enables the ramped DC voltage signal change
OFF(0) Disables the ramped DC voltage signal change (default)
Parameter
<dcv_numeric>
Value:
0 to 445.0
DC voltage (The default value is 0)
Unit:
V
Parameter
<time_numeric>
Value:
0.0001 s to 1000h Step time (The default value is 0.01 s)
Unit:
S