Remote Sensing
1
Inst
allation an
d Prep
aratio
n
Wiring Procedure
1
Turn off the POWER switch.
2
Connect the sensing terminals to the load by using sensing cables.
Connect both the OUTPUT OUT terminal and the SENSING OUT terminal to the same
terminal on the load. Connect both the OUTPUT COM terminal and the SENSING
COM terminal to the other terminal on the load.
To avoid noise induction, use a two-wire shielded cable to connect the sensing
terminals. Connect the shield to the OUTPUT COM terminal. If you cannot use a
shielded cable, twist the sensing cables from the OUT terminal and the COM terminal
together.
When remote sensing is enabled, if the sensing terminals are shorted, opened, or are wired
in reverse, the sensing protection is activated, and the output voltage in CV mode is limited
within the specified voltage ± approximately 3.6 V. When the connection is fixed, the
protection feature automatically recovers. Do not leave the PBZ while the sensing protection
is activated.
CAUTION
• This procedure may damage the internal workings of the PBZ. Do not mis-wire the
SENSING terminals by wiring the cable for the OUT terminal to the COM terminal and vice-
versa.
Two-wire shielded cable
Load
OUTPUT
Chassis
terminal
SENSING
OUT
COM
OUT
COM
Содержание PBZ20-20
Страница 11: ...PBZ 11 ...
Страница 18: ...18 PBZ ...
Страница 75: ...Memory Response and Configuration This chapter explains preset memory setup memory response and configura tion ...
Страница 95: ...Sequences This chapter explains sequences ...
Страница 153: ...Maintenance This chapter describes how to clean and inspect the PBZ ...
Страница 156: ...156 PBZ Maintenance ...
Страница 157: ...Appendix A List of Factory Default Settings B Troubleshooting C List of Error Messages D Options ...