4.7
CONFIG Settings
CONFIG settings are used to set the system configuration of the PAT. You can set
or display the parameters in Table 4-1 in the CONFIG settings. On the top panel of
the PAT is a label that indicates a list of CONFIG parameters and settings.
Table 4-1
CO
N
FIG parameters
Parameter
n
u
mber
Indication on the top
panel label
Description of the setting or display
CF01
ALARM
Alarm ca
u
se display
CF02
REMOTE SE
N
SI
N
G
Remote sensing stat
u
s display
CF10
O
N
DELAY
O
u
tp
u
t on delay setting
CF11
OFF DELAY
O
u
tp
u
t off delay setting
CF12
PRESET KEYLOCK
Preset recall setting
w
hile locked
CF13
ERR TRACE
Comm
u
nication error display setting
*1
CF20
CV CO
N
TROL
CV control so
u
rce setting
*2
CF21
CC CO
N
TROL
CC control so
u
rce setting
CF22
EXT OUT CTRL
External control logic setting of the o
u
tp
u
t on/off
CF23
PWR O
N
/OFF STATUS Stat
u
s signal setting of the po
w
er on/off
CF24
PARALLEL
Setting the n
u
mber of
u
nits in Master-Slave Parallel Operation
CF25
POWER O
N
OUTPUT
O
u
tp
u
t stat
u
s setting at po
w
er-on
CF26
MASTER/SLAVE
Master-slave parallel operation setting
CF27
BREAKER TRIP (SD)
Breaker trip setting
w
hen the sh
u
tdo
w
n signal is applied
CF2
8
BREAKER TRIP
Breaker trip setting
w
hen the OVP or OCP is activated
CF29
V SETTI
N
G LIMIT
Voltage limit setting
CF30
I SETTI
N
G LIMIT
C
u
rrent limit setting
CF31
PHASE SELECT
Phase inp
u
t mode setting (three-phase inp
u
t/single-phase inp
u
t)
CF40
BAUDRATE
RS232C data rate setting
CF41
DATABITS
RS232C data length setting
CF42
STOPBITS
RS232C stop bit setting
CF43
FLOW
RS232C flo
w
control setting
CF50
VERSIOI
N
Interface version display
*3
CF51
GPIB ADDRESS
GPIB address setting
*4
CF52
VE
N
DOR ID
Vendor ID display
*5
CF53
PRODUCT ID
Prod
u
ct ID display
CF54
ADDO
N
I/F
Remote interface setting
CF55
DHCP CLIE
N
T
DHCP setting
*6
CF56
AUTO IP ADDRESS
AUTO IP address setting
CF57
IP ADDRESS (1)
IP address display (1)
CF5
8
IP ADDRESS (2)
IP address display (2)
CF59
IP ADDRESS (3)
IP address display (3)
CF60
IP ADDRESS (4)
IP address display (4)
CF61
LA
N
STATUS
LA
N
stat
u
s display
*1.
The setting is possible even
w
hen the prod
u
ct is
u
sed as a slave
u
nit.
*2.
Cannot be set
w
hen the o
u
tp
u
t is on.
*3.
Only
w
hen the factory option GPIB, USB or LA
N
interface is installed.
*4.
Only
w
hen the factory option GPIB interface is installed.
*5.
Only
w
hen the factory option USB interface is installed.
*6.
Only
w
hen the factory option LA
N
interface is installed.
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...