7-6
PAT-T 4KW
7.4.2
GPIB Interface (Option)
This interface valid only when the factory option GPIB interface board is installed.
GPIB connection
Use a standard IEEE488 cable to connect the PAT to the computer.
GPIB configuration
1
Select GPIB (CF54: GPIb) in the CO
N
FIG settings.
2
Set the address (CF51: 1 to 30) in the CO
N
FIG settings.
The address is set to 1 as factory default setting.
GPIB function
Table 7-3
GPIB f
u
nction
Service request
Service request and serial polling functions are implemented.
See
F
u
nction
S
u
bset
Description
So
u
rce handshaking
SH1
F
u
ll capability
Acceptor handshaking
AH1
F
u
ll capability
Talker
T6
F
u
nction available
Listener
L4
F
u
nction available
Service req
u
est
SR1
F
u
ll capability
Remote local
RL1
F
u
ll capability
Parallel polling
PP0
N
o capability
Device clear
DC1
F
u
ll capability
Device trigger
DT1
F
u
ll capability
Controller
C0
N
o capability
Electrical interface
E1
Open collector driver
Содержание PAT160-25T
Страница 17: ...General Description This chapter describes an overview and describes the features...
Страница 22: ...1 6 PAT T 4kW...
Страница 34: ...2 12 PAT T 4kW...
Страница 73: ...External Control This chapter describes external analog control and remote monitoring using the J1 connector...
Страница 106: ...6 12 PAT T 4kW...
Страница 158: ...7 52 PAT T 4KW...
Страница 159: ...Maintenance This chapter describes maintenance such as cleaning inspecting and calibrating...
Страница 171: ...Specifications This chapter describes the specifications and gives the dimensions of the PAT...