background image

6

149-10A

Safety Symbols

This operation manual and this product use the following safety
symbols. Note the meaning of each of the symbols to ensure safe use
of the product. (As using symbols depend on the product, all of
symbols may not be used.)

I

ndicates the presence of 1000V or higher.

Inadvertently touching such a part may cause electrical
shock resulting in death.  If it is necessary to touch
such a part to conduct work, first make sure no voltage
is being supplied.

Indicates the possibility of personal injury or death.
Never fail to follow the operating procedure.  Do not
proceed beyond a WARNING sign until the noted
conditions are fully understood and met.

Indicates the existence of damage to the product or
connected equipment. Always follow the operating
procedure.  Do not proceed beyond a CAUTION sign
until the indicted conditions are fully understood and
met.

Indicates additional information such as operating
procedure.

Describes technical terms used in this manual.

Indicates action prohibited.

Indicates general warning, caution, risk of danger.
When this mark is indicated on the product, refer the
relevant section of the Operation Manual.

Indicates a protective conductor terminal.

Indicates a chassis (frame) terminal.

or

 Description 

 WARNING 

  NOTE  

 CAUTION 

Содержание 149-10A

Страница 1: ...Part No Z1 109 820 IA001705 Jul 2016 149 10A OPERATION MANUAL High Voltage Digitalmeter ...

Страница 2: ...he manual gets lost or soiled a new copy can be provided for a fee In either case please contact Kikusui distributor agent and provide the Kikusui Part No given on the cover This manual has been prepared with the utmost care however if you have any questions or note any errors or omissions please contact Kikusui distributor agent Reproduction and reprinting of this operation manual whole or partia...

Страница 3: ..._______ to _____________Vac Use the product within this range only Input fuse The rating of this product s input fuse is _____________ A _____________ Vac and ______________ WARNING To avoid electrical shock always disconnect the power cord or turn off the switchboard before attempting to check or replace the fuse Use a fuse element having a shape rating and characteristics suitable for this produ...

Страница 4: ...rawing WARNING The attachment of a plug of power cord or crimp style terminals must be carried out by qualified personnel Blue NEUTRAL Brown LIVE Green Yellow GND White NEUTRAL Black LIVE Green or Green Yellow GND Kikusui agents can provide you with suitable power cord For further information contact Kikusui distributor agent NEMA5 15 CEE7 7 GB1002 Without a plug Without a plug Plug for Europe Plu...

Страница 5: ...it under supervision of qualified personnel those who have electrical knowledge This product is not designed or manufactured for general home or consumer use Purposes of use Do not use the product for purposes other than those described in the operation manual Input power Use the product with the specified input power voltage For applying power use the power cord provided Note that the provided po...

Страница 6: ...n installing products with casters be sure to lock the casters Relocation Turn off the power switch and then disconnect all cables when relocating the product Use two or more persons when relocating the product which weights more than 18 kg The weight of the products can be found on the rear panel of the product and or in this operation manual Use extra precautions such as using more people when r...

Страница 7: ...tely repaired For output wiring or load cables use connection cables with larger current capacity Do not disassemble or modify the product If it must be modified contact Kikusui distributor agent Maintenance and checking To avoid electrical shock be absolutely sure to unplug the power cord or stop applying power before performing maintenance or checking To maintain performance and safe operation o...

Страница 8: ...ail to follow the operating procedure Do not proceed beyond a WARNING sign until the noted conditions are fully understood and met Indicates the existence of damage to the product or connected equipment Always follow the operating procedure Do not proceed beyond a CAUTION sign until the indicted conditions are fully understood and met Indicates additional information such as operating procedure De...

Страница 9: ...equirements 9 2 3 Connecting the Power Cord 10 Chapter 3 Operation Method___________________ 11 3 1 Part Names and Functions 11 3 2 Measuring Method 12 3 2 1 Measuring Procedure 12 3 2 2 To Correct the Meter Reading for High Impedance Measured Object 14 3 2 3 Measured Object s Polarity and Ground 14 Chapter 4 Specifications ______________________ 16 Chapter 5 Calibration ________________________ 1...

Страница 10: ... as high as 1000MΩ the meter is best suited for measurement of voltages of high source impedance circuits The meter is compact and light approx 3kg but its measuring accuracy is high Thus the meter can also be used conveniently as a portable calibration instrument or to calibrate the voltage of a withstanding voltage tester General Description Chapter 1 ...

Страница 11: ...as follows Nominal voltage 100 V Voltage tolerance 10 of nominal voltage Nominal frequency 50 60 Hz Testers that operate on other AC line voltages as shown below also are available as factory modification options 110 V 120 V 220 V 230 V or 240 V The following table is printed on the rear panel of the tester If nothing is marked in the LINE VOLTAGE column the nominal voltage is 100 V If a change ha...

Страница 12: ...to the AC line Do not use the supplied power cord with other instruments The power cord with a plug can be used to disconnect the product from the AC line in an emergency Connect the plug to an easily accessible power outlet so that the plug can be removed from the outlet at any time Secure adequate space around the power plug Do not insert the power plug to an outlet where accessibility to the pl...

Страница 13: ... the measured voltage AC DC Mode selection switcch LEDs indicate selected mode POWER AC power switch LOW Terminal for ground line of measured input voltage INPUT Terminal for high potential line of measured input voltage CALIBRATION AC DC Semi fixed resistors for calibration Do not touch these resistors except when calibrating the meter Plastic screw Fixes the test lead red Fig 3 1 Front panel Rea...

Страница 14: ...ere or the meter is used continuously for a long time with a high voltage being input dust may be collected on the INPUT terminal section Because input resistance degradation or voltage dividing ratio disturbance clean at appropriate intervals the INPUT terminal and the internal insulators using a clean dry cloth The AC DC converter of the 149 10A is a mean value response system and is calibrated ...

Страница 15: ... the INPUT terminal of thr tester and fix the lead with the plastic screw 5 Set the AC DC switch in accordance with the output of the measured object 6 Connect the supplied high voltage test lead red to the high voltage side of the measured object 7 Check that the 149 10A and measured object are connected as shown in Fig 3 3 8 Turn on the power of the measured object 149 10A High voltage test lead...

Страница 16: ...bove when the internal impedance is lower than 10MΩ the error caused impedance wise is less than 1 Measurement can be done with an accuracy of this error plus meter accuracy 3 2 3 Measured Object s Polarity and Ground Be sure to connect the power cord of the 149 10A to a properly grounded outlet If grounding is not possible through the power cord ground the protective conductor terminal on the rea...

Страница 17: ...de GND side of the measured object is unknown determine it by following the procedure below and connect properly How to determine the polarity of the measured object As shown in Fig 3 5 connect a high voltage test lead to terminal A or B and assume the side with the higher voltage reading to be the high voltage side 149 10A High voltage test lead A B Measured object Ground Fig 3 5 Polarity check ...

Страница 18: ... integration type 3 samples sec Input resistance Ambient temperature and humidity 0 C to 35 C 32 F to 95 F 80 RH External dimensions Maximum dimension Weight Approx 3 kg 6 6 lbs Power cord 1 TL05 TOS High voltage test leads 1 set HTL2 5DH High voltage test lead 1 Operation manual 1 Overall Dimentions Accessories Maximum allowable input voltages Specification For AC measurement mean value response ...

Страница 19: ... calibrating the 149 10A pay full attention for safety Before calibration warm up the 149 10A for at least 60 minutes Calibration Set the 149 10A in the DC mode apply a calibration voltage of 10 kV DC to the input terminal of the meter and so adjust CALIBRATION DC semi fixed resistor on the side panel of the 149 10A that it displays 10 000 Next set the 149 10A in the AC mode apply a calibration vo...

Страница 20: ...he replacement fuse is of the correct shape and rating for mater specifications Never use a fuse having a different rating never short circuit the fuse holder 1 Turn off the POWER switch and unplug the power cord from the outlet 2 Disconnect the power cord from the AC inlet on the rear panel 3 Use a screwdriver to remove the fuse holder as shown in Fig 5 1 Fuse Fig 5 1 Fuse holder ...

Страница 21: ...149 10A 19 Block Diagram Chapter 5 ...

Страница 22: ...KIKUSUI ELECTRONICS CORP http www kikusui co jp en 1 1 3 Higashiyamata Tsuzuki ku Yokohama 224 0023 Japan Tel 81 45 593 7570 Fax 81 45 593 7571 Website ...

Отзывы: