10
HES and SEL
Operating instructions
4 Technical data
CO
NFIDENTIAL
4
Technical data
4.1
General technical data
In compliance with the following
standards and regulations
EN 60947-5-1
VDE 0110 – Pollution degree 2 (inside), 4 (outside)
Suitable for
Controls and installations according to EN 60204
Casing
HES: Aluminum, SEL: Gray cast iron
Mounting
HES: two slotted holes for M 8 screws
SEL: two slotted holes for M 10 screws
Permissible ambient temperature
- 25 °C to + 70 °C,
Permissible storage temperature
- 25 °C to + 70 °C,
Max. altitude above sea level
2.000 m (contact manufacturer for installation on sites at higher altitudes)
Protection standard
IP 67 according to EN 60529
Switching system
Snap-acting switch, max. four positive-opening change-over contacts,
see also
Type of drive
Cylindrical roller made from stainless steel, Ø 48 mm
Switch points
Adjustable: 5° to 15° and 15° to 35°
Default setting: 2 x 10°
Deflection of the roller lever
Max. 75°
Rated insulation voltage U
i
AC 380 V, DC 250 V
Conventional thermal current I
th
6 A
Breaking capacity
AC-15: U
e
= AC 230 V, I
e
= 1.5 A
DC 24 V, t = 2 ms to 3 ms, to 3 A