Technical Specifications

Issue 2015-01-09

11 Technical Specifications

11.1 Technical data

Power supply

Dual power supply consisting of a solar cell and an internal energy
storage unit with priority management

Internal energy storage uses 2 replaceable 3.6 V AA lithium 
batteries

Measured quantity Room temperature in homes or offices
Measuring system Integrated digital sensor
Temperature units °F or °C, can be configured
Measuring range

32..122 °F (0..50 °C)

Relative measure-
ment precision

0.1 K

Display

LCD:

Time

Weekly schedule

Icon to indicate operating mode

Setpoint in the temperature units selected
50..85 °F, resolution 1 °F
(10.0..30.0 °C, resolution 0.1 K)

Controls

Setting knob with confirmation button for setting: Setpoint, party 
mode, vacation mode, weekly schedule, time, date, display 
options (e.g. 12/24 hour display) and service data

Occupancy button: Manually switch between present or 

absent

Interfaces between 
the 
RBW322-FTL-902 
and the 
MD15-FTL-902

 technoLink® wireless interface:

Radiogram: EnOcean radiogram, bidirectional

Frequency: 902.875 MHz

Duty cycle: < 1 %

Cyclic transmission or reception intervals

Transmission 
power

< 10 mW

Illuminance for 
solar cell

Min. 150 lux recommended

Operating range

Approx. 30 m in buildings (depending on building substance)

Housing

Plastic housing, RAL 9010 (pure white)
Other colors on request

Protection class

III

Содержание RBW322-FTL-902

Страница 1: ...Issue 2015 01 09 Operating Instructions RBW322 FTL 902 Room Control Module...

Страница 2: ...s 6 2 3 Intended use 6 2 4 Responsibilites of the Operator 7 3 Equipment Description 7 3 1 Components 8 4 Packaging transportation and storage 8 4 1 Packaging 8 4 2 Transportation 9 4 3 Storage 9 5 Op...

Страница 3: ...he initial display 18 Setting the 12 24 hour mode 18 Switching the temperature units between F C 19 8 Maintenance and Cleaning 19 8 1 Maintenance 19 8 2 Cleaning 19 9 Malfunctions 19 10 Decommissionin...

Страница 4: ...lidity and storage of the operating instructions These operating instructions are an integral part of the RBW322 FTL 902 and apply exclusively to this device Keep the operating instructions in the imm...

Страница 5: ...ep that must be performed 1 2 Scope of Delivery The standard scope of delivery includes RBW322 FTL 902 room control module incl batteries Holding plate Adhesive pad Installation note RBW322 FTL 902 2...

Страница 6: ...operate the device in wet or moist environments Do not operate the device in a potentially explosive environment Do not open the device Only operate the RBW322 FTL 902 when it is in original condition...

Страница 7: ...ssage is issued except when batteries are changed in the MD15 FTL 902 radio partner you must inform your service technician 3 Equipment Description You can use the RBW322 FTL 902 room control module t...

Страница 8: ...terial for the packaging The packaging must not be too large or too small Use packing material to prevent the device from sliding Carefully close and seal the packaging 01 Display Displays information...

Страница 9: ...vidual temperature profiles There are three different operating modes available that enable you to set a specific room temperature In the configuration menu of RBW322 FTL 902 Room Control Module you c...

Страница 10: ...he occupancy button is pressed again 1 Setting knob Turn Set value e g setpoint Turn counterclockwise Reduce value Turn clockwise Increase value Press 2 seconds Change menus or Press briefly Set setpo...

Страница 11: ...ss communica tion established at least one radio partner has been taught in Wireless communication icon not visible wireless commu nication not established no radio partners have been taught in or all...

Страница 12: ...ng the occupancy button Press the occupancy button for 2 seconds to switch summer mode on or off 7 2 Operating Menu The following functions are available on the operating menu Setting the setpoint 7 2...

Страница 13: ...figuration menu as follows Press the setting knob for 2 seconds Turn the setting knob clockwise to access the individual setting functions NOTE The individual setting functions are exited if the setti...

Страница 14: ...at least 2 days Vacation mode overwrites deactivates the set weekly schedule for the specified time Press the setting knob for 2 seconds Turn the setting knob clockwise to set vacation mode Set vacat...

Страница 15: ...arly Press the setting knob Deleting an inactive vacation mode Set the vacation start equal to the vacation end Perform the settings as described above NOTE The vacation period must be at least 2 days...

Страница 16: ...etting of the usage times early The bar display shown indicates the usage times of the current day If a usage time is active the controller operates in comfort mode In addition the icon is shown on th...

Страница 17: ...pressing the setting knob 7 3 6 Setting the time and date Press the setting knob for 2 seconds Use the setting knob to select the Time date function TIME Press the setting knob Set the hour minutes y...

Страница 18: ...time Initial display temperature or Initial display setpoint Press the setting knob The display switches to the initial display set by the user Default setting Initial display time Setting the 12 24...

Страница 19: ...cleaned as necessary There is no prescribed cleaning interval Clean the RBW322 FTL 902 with a lint free lightly moistened cloth Do not use any aggressive cleaning products 9 Malfunctions The room con...

Страница 20: ...your service technician Wireless communication to the taught in EnOcean system gateway is interrupted The battery level of at least one MD15 FTL 902 is too low 10 If no signal is received from the MD...

Страница 21: ...vice menu Press the setting knob for 2 seconds Use the setting knob to select the Service menu SR Press the setting knob Enter the four digit access code 4321 Each digit is entered individually and co...

Страница 22: ...the screws by turning the flat screwdriver in counter clockwise direction 10 2 2 Adhesive mounting If you want to remove the room control module proceed as follows NOTICE Damage to the mounting surfac...

Страница 23: ...ard Separate the room control module from the holding plate Remove the adhesive pad from the wall and the holding plate 10 3 Disposal The device RBW322 FTL 902 room control module is an electrical dev...

Страница 24: ...in the temperature units selected 50 85 F resolution 1 F 10 0 30 0 C resolution 0 1 K Controls Setting knob with confirmation button for setting Setpoint party mode vacation mode weekly schedule time...

Страница 25: ...and the MD15 FTL 902 is interrupted a new teach in procedure is automatically triggered internally NOTE This device uses only EnOcean radiograms Only the MD15 FTL 902 can be used as a radio partner D...

Страница 26: ...Type plate The RBW322 FTL 902 type plate is located on the back of the device behind the holding plate 01 RBW322 FTL 902 type plate 02 Serial number 03 Identification number 04 Frequency 05 Device app...

Страница 27: ...ter This device is capable of compliance with localized specific absorption rate SAR for uncontrolled environment general public exposure limits specific in ANSI IEEE C95 1 1992 and has been tested in...

Страница 28: ...A Magnum Energy Solutions LLC 43 Village Way 209 Hudson OH 44236 1 330 656 9365 telephone 1 866 271 3961 toll free 330 656 9368 fax Type of antenna integrated onboard PCB antenna permanently attached...

Страница 29: ...Contact data 29 Issue 2015 01 09...

Страница 30: ...30 Contact data Issue 2015 01 09...

Отзывы: