background image

A

Page 9 / 12

Datasheet 1.10-60.010-01-EN

RBW301-C, RBW302-C, RBW304-C, RBW305-C

Product Description

Issue 2017-07-20

Setting the room temperature

Requirements: Indicator on the display: 

Rotate or press the knob. 

The temperature value is displayed and flashes. 

Rotate right: Increase the temperature. Rotate left: Reduce the temperature.

The temperature can be set over a range of up to +/-9.9 degrees. 

Press the knob: The preset temperature is saved and displayed. 

The temperature is regulated accordingly.

Energy saving function (RBW304-x, RBW305-x)

Switch the presence button to “Absent” when you leave the room for a longer period of time. 
Indicator on the display: 

The energy saving function is activated and the temperature is set to a preconfigured value 
(can be displayed, but not adjusted).

Switch the presence button to “Present” when you return to the room.  
Indicator on the display: 

The energy saving function is switched off. The temperature is regulated accordingly.  

Schedule

(Supported by RCC200-L, RCN200-L and DDC420)

Setting the timer

The following schedules (two timers in each case) are available: MO FR (working days), SA SU 
(weekend), MO SU (week) as well as MO TU WE TH FR SA SU for the individual days.

Press and hold the knob for three seconds.

The schedules are displayed. 

Rotate the knob: Select the schedule. Press the knob: Confirm selection.

First timer

The start time

 is displayed and flashes. Indicator on the display: , time, 

.

Rotate the knob: Set the start time. Press the knob: Confirm the setting.

First timer

The end time

 is displayed and flashes. Indicator on the display: , time, 

.

Rotate the knob: Set the end time. Press the knob: Confirm the setting. 

The display switches to the start time of the second timer. 

Second timer

: If required, set in the same way as for the first timer and confirm. Indicator on 

the display: 

, time, 

The timer settings are shown on the display on the corresponding day of the week.

Deleting the second timer

Select the timer end time as described above. Indicator on the display:  , time, 

Rotate the knob to the left (end time = start time). Press the knob: Confirm the setting.

Timer is deleted and is no longer displayed. 

Deleting the first and second timers

Select the end time of the first timer as described above. Indicator on the display:  , time, 

Rotate the knob to the left (end time = start time). Press the knob: Confirm the setting.

The first and second timer have been deleted and are no longer displayed. 

Содержание RBW301-C

Страница 1: ...le Application Room control module with display room temperature sensor and manual setting of the room temperature setpoint for the following room controllers and automation systems RCN150 L RCN151 L...

Страница 2: ...ystem installer or operator to comply with local regulations Mounting installation and commissioning work on the devices may only be carried out by qualified technicians Qualified technicians are pers...

Страница 3: ...splay Feedback presence fan status heating cooling window contact weekly schedule time date project specific messages service level Knob with confirmation key for setting the temperature time and week...

Страница 4: ...CN200 L or RCN420 B room controllers up to four room control modules depending on the application DDC420 automation station up to 3 room control modules DDC4200 L DDC4200 DDC4002 DDC4400 DDC4200e DDC4...

Страница 5: ...20 RBW20X C RBW30X C RCN420 B 21 20 19 22 0V 12VDC CAN CAN 0V DC 12V DC 19 18 17 20 52 53 50 51 9 8 7 16 15 10 3 2 1 6 5 4 57 60 59 58 GND K1 P1 GND K3 GND P3 GND K2 P2 13 12 11 14 GND K4 GND P4 GND P...

Страница 6: ...removal may only be carried out by qualified technicians when the power is switched off Choose an installation location that is subject to the air flow of the room to ensure that the room controller...

Страница 7: ...RBW302 C RBW304 C RBW305 C Product Description Issue 2017 07 20 Mounting on standard flush mounted box 4 wire on terminal Direct wall mounting with Z146 adapter frame 4 wire on terminal 1 2 3 4 5 6 Z...

Страница 8: ...witch on time for the utilization schedule timer and Absent No settings can be made Additionally Display of the switch off time for the utilization schedule timer and Fan in automatic operating mode T...

Страница 9: ...ng days SA SU weekend MO SU week as well as MO TU WE TH FR SA SU for the individual days Press and hold the knob for three seconds The schedules are displayed Rotate the knob Select the schedule Press...

Страница 10: ...the TIME function Press the knob Confirm selection Set the time Set the hour Confirm the setting Set the minute Confirm the setting Set the date Set the year Confirm the setting Set the month Confirm...

Страница 11: ...trol modules that lights up green Notes for service technicians Additional indicators on the display Querying the service settings Press and hold the knob for three seconds Rotate the knob Select the...

Страница 12: ...A Page 12 12 Product Description RBW301 C RBW302 C RBW304 C RBW305 C Datasheet 1 10 60 010 01 EN Issue 2017 07 20...

Отзывы: