background image

Technical data sheet  1.15-10.002-01-en

 

Multi radio connection MFA

 

D e v i ce   De s c ri p ti on

 

 
 

Notes on the device description

 

The description contains instructions on using and assembling the Multi Radio Controller MFA.

 

In case of questions which cannot be clarified with this device description, please refer to the supplier or 
manufacturer for further information.

 

 
The indicated installation instructions/regulations are valid in the Federal Republic of Germany.

 

When using the I/O components in other countries, the builder or operator of the plant is responsible for 
compliance with the respective national regulations.

 

 
The operating staff is to be instructed in accordance with the description of the technical data sheet.

 

 
 

Safety Instructions

 

The currently valid worker’s occupational health regulations and regulations for the prevention of industrial 
accidents must be observed when assembling and using the modules.

 

 
Any work concerning the installation or initial operation of the modules shall be exclusively carried out by qualified 
specialists, see paragraph “Qualified specialists”.

 

 
Every person utilizing the devices shall have read and understood the descriptions in the technical data sheet.

 

 
Meaning of the symbols in the technical data sheet:

 

 
 

 

Warning of dangerous electrical voltage

 

 

Danger

 

 

 

 

 

General warning, strictly observe this notice

 

Warning

 

 

 

 

 

Further notice to observe

 

Note

 

 

 

 

Danger

 

means mortal danger, severe bodily injuries or serious material damage in case of 
non-observance.

 

Warning

 

means danger of bodily injuries or material damage in case of non-observance.

 

Note

 

indicates an information which is particularly stressed.

 

 
 

Qualified specialists

 

Qualified specialists for the purposes set out in this technical data sheet are persons who are familiar with the described 
devices and possess a qualification for their respective occupation.

 

These are for instance:

 

 

Authorization to connect the devices according to the VDE rules and local Electricity Board regulations, as 
well as the authorization to switch the devices on and off taking the in-house regulations into account.

 

 

Knowledge of the regulations for prevention of accidents.

 

 

Knowledge of the utilization of the devices within the plant system.

 

 

etc.

 

 

 

Page 2 / 8

 

Содержание Multi radio connection MFA

Страница 1: ...ly Contents Notes on the device description Page 2 Safety Instructions Page 2 Qualified specialists Page 2 Application Page 3 Type Page 3 Technical data Page 3 Assembly Page 4 Installation Page 6 Connection Page 6 Addressing Page 6 Initial operation Page 8 Kieback Peter GmbH Co KG Tempelhofer Weg 50 D 12347 Berlin Telephone 49 0 30 600 95 0 Telefax 49 0 30 600 95 164 E Mail info kieback peter de h...

Страница 2: ... carried out by qualified specialists see paragraph Qualified specialists Every person utilizing the devices shall have read and understood the descriptions in the technical data sheet Meaning of the symbols in the technical data sheet Warning of dangerous electrical voltage Danger General warning strictly observe this notice Warning Further notice to observe Note Danger means mortal danger severe...

Страница 3: ...us small servo drives of the types M25Y or M15Y S2 MFA Type MFA Multi radio connection as a radio converter for the indirect wireless activation of up to two wire connected continuous small servo drives With integrated switching power supply 230 V AC 24 V DC Technical data Primary mains 230 V AC 10 12 VA Secondary mains 24 V AC 15 7 VA Received frequency 868 35 MHz Analog output 0 10 V DC 5 mA Deg...

Страница 4: ...rials and screening elements e g installation shafts fire doors switching cabinet doors etc must already be taken into account during the planning phase High humidity increases the natural signal attenuation Warning Recommendation Plan the radio paths horizontally on one level with max 30 m distance between transmitting and receiving components Note Observe the minimum distances to potential sourc...

Страница 5: ...he cable entry Cable inlet for assembly with flush mounted box Cable inlet for surface mounted installation application of the hood for wall mounting 1 Release safety screw and take off hood Hood inserts as extra item 2 Cable inlet from the back breakout 5mm 60 M3 x 20 60 M3 5 x 45 Cable inlet from below After the housing lead through of the cable provide a traction relief Warning 3 Wire MFA accor...

Страница 6: ...ection diagram or the applicable appliance connection scheme Connection MFA Use only small servo drives with DC power supply Note Addressing In the housing the MFA has 3 rotary switches for setting the system code and the device address By means of the 3 digit address code radio paths can be established with theoretically up to 999 participants Terminals small servo drives Service key multi colore...

Страница 7: ... 10 V Adr 01 0 MFA Adr 01 0 Setting the address code The 3 digit address code consists of a 1 digit system code and a 2 digit device address Example for address 23 1 Device address 23 0 1 2 3 4 5 6 7 8 9 x1 x10 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 Device address System code System code 1 Via the system code participants of a radio network can be grouped according to different criteria e g floor...

Страница 8: ... Specific settings and functions of the MFC are described in this device description Additionally to this notice the device documentation MFC and FCS are to be noted Set the address code The same address code must be set at the assigned transmitting modules as well The device is delivered with the setting 000 Warning Training with the MFA and the corresponding field device takes place automaticall...