 CONTENTS OF THIS USER GUIDE

 

1 —  LIMITATIONS OF SMOKE AND CARBON MONOXIDE ALARMS

 

2 —  RECOMMENDED LOCATIONS FOR ALARMS

 

3 —  LOCATIONS TO AVOID

 

4 —  INSTALLATION / MOUNTING INSTRUCTIONS

 

5 —  OPERATION AND TESTING

 

6 —  VISUAL AND AUDIBLE INDICATIONS

 

7 —  NUISANCE AND HUSH

 

8 —  BATTERY

 

9 —  PERMANENTLY DISABLE ALARM / DISCHARGE BATTERY

 

10 —  CLEANING

 

11 —  GENERAL CARBON MONOXIDE (CO) INFORMATION

 

12 —  GOOD SAFETY HABITS

 

13 —  SERVICE AND WARRANTY

This alarm detects products of combustion using photoelectric technology 
and carbon monoxide using an electrochemical cell. Many times throughout 
this User Guide, we will refer to Carbon Monoxide as “CO.” 

This alarm is acceptable for use near kitchens or cooking areas but can 
be used in all other residential applications where a smoke or CO alarm is 
required.

After ten (10) years of cumulative power up, this unit will “chirp” two times 
every 30 seconds. This is an "operational end of life" feature which will indi-
cate that it is time to replace the alarm.

To help identify the date to replace the unit, a label has been affixed to the 
side of the alarm. Write the “Replace by” date (10 years from initial power 
up) in permanent marker on the label prior to installing the unit.

Product Features and Specifications:

• Temperature: Operating Range: 40°F (4.4°C) to 100°F (37.8°C) 
• Humidity: Operating range: 10-95% non-condensing 
• Audible Alarm: 85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm 
• Smoke Sensor: Photoelectric 
• CO Sensor: Electrochemical

Two labels have been provided that have important information on what  
to do in case of a CO alarm. Place one label next to the alarm after it is 
mounted, and one near a fresh air source such as a door or window.

Содержание P3010K-CO

Страница 1: ...monoxide from any source of combustion in a residential environ ment It is not designed for use in a recreational vehicle RV or boat P N P N 2534 7221 01 RevA For your convenience write down the follo...

Страница 2: ...pen that door Instead use your alternate exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in Stay close to the...

Страница 3: ...d appliance technician to investigate sources of CO from fuel burning equipment and appliances and to inspect for proper operation of equipment If problems are identified during this inspection have t...

Страница 4: ...applications where a smoke or CO alarm is required After ten 10 years of cumulative power up this unit will chirp two times every 30 seconds This is an operational end of life feature which will indi...

Страница 5: ...sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ion ization alarms Home fires develop in different wa...

Страница 6: ...as defined in the National Electric Code It is not designed for use in a recreational vehicle RV or boat The installation of this device should not be used as a substitute for proper installation use...

Страница 7: ...alarm in every bedroom Locate an alarm in every room where electrical appliances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door close...

Страница 8: ...OBILE HOME INSTALLATION Modern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended above In older mobile homes that are not well insulated compared to...

Страница 9: ...rm or failure to alarm In very humid areas Moisture or steam can cause nuisance alarms In insect infested areas Smoke alarms should not be installed within 3 ft 9m of the door to a bathroom containing...

Страница 10: ...n Section 2 attach the mounting bracket to the ceiling as shown in Image 4 For wall mounting see Image 5 Place the mounting plate on the wall be sure the A line is horizontal parallel to the floor Use...

Страница 11: ...icks into place If unit needs to be re aligned rotate the alarm counter clockwise remove and rotate to desired alignment NOTE The alarm will mount to the plate in three 3 positions every 120 degrees Y...

Страница 12: ...D light The CO sensor meets the alarm response time as follows At 70 PPM the unit must alarm within 60 240 minutes At 150 PPM the unit must alarm within 10 50 minutes At 400 PPM the unit must alarm wi...

Страница 13: ...tact Product Support at 1 800 880 6788 or write us at Kidde 1016 Corporate Park Drive Mebane NC 27302 Our internet address is www kidde com End of life hush feature Silences end of life indication 3 d...

Страница 14: ...feature and sound a continuous alarm CAUTION Before using the alarm SMART HUSHTM feature identify the source of the smoke and be certain safe conditions exist 8 BATTERY NOTE One lithium battery perman...

Страница 15: ...LARM DISCHARGE BATTERY WARNING Failure to discharge alarm as instructed prior to disposal may create potential for lithium battery related fire or hazard After the tab is broken use the screwdriver to...

Страница 16: ...n transient CO situations Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as Wind direction and or velocity including high gusts of wind heav...

Страница 17: ...scussed with ALL members of the household 1 Mild Exposure Slight headache nausea vomiting fatigue often described as Flu like symptoms 2 Medium Exposure Severe throbbing headache drowsiness confusion...

Страница 18: ...d may cause false read ings and damage to the sensor Methane propane isobutane iso propanol ethyl acetate hydrogen sulfide sulfide dioxides alcohol based products paints thinner solvents adhesives hai...

Страница 19: ...test your plan before an emergency You may not be able to reach your children It is important they know what to do Familiarize everyone with the sound of the smoke CO alarm and train them to leave yo...

Страница 20: ...might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the house holder co...

Страница 21: ...e include your name address and phone number along with a brief description of what is wrong with the unit For further assistance please call our toll free Customer Service at 1 800 880 6788 Damage fr...

Страница 22: ...indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligence strict liability in...