background image

Carbon Monoxide Alert Procedure

Low Level Alert

WARNING: Alerts to the presence of constant low level CO

concentrations (less than 30 ppm). These constant low levels may
pose potential health risks for individuals with certain pre-exist-
ing health or medical conditions.  You must consult your health
care provider as to any potential low level CO exposure risk due
to any specific pre-existing heath or medical conditions.

1) Operate the Test/Reset button;

2) If a constant low level of Carbon Monoxide (below 30 ppm) is meas-
ured and persists in your home you should consult your healthcare giver
about the long term impact on your health.

3) Move all occupants to fresh air to avoid any immediate health repercussions.

4) After following steps 1-3, if the unit goes into full alarm follow the
Carbon Monoxide Monitor Procedure for response and evacuation. 

If the unit is sounding, pressing the test/reset button will termi-
nate the notification. If the CO condition that caused the alert in
the first place continues, the unit will reactivate in alert or full
alarm mode. If the unit goes into full alarm again within six min-
utes, it is sensing high levels of CO which can quickly become a
dangerous situation.

This CO monitor operates differently than CO and smoke alarms. Like
smoke and CO alarms, this CO monitor samples the air in your home
and sounds a loud alarm to warn you of life threatening conditions. In
addition, this monitor will alert you to lingering low levels of CO (below
30 ppm) which may have heath implications if you suffer from certain
pre-existing health or medical conditions. You should discuss your specif-
ic needs for a low level CO monitor with your healthcare provider to
determine if a low level CO monitor is warranted given a particular pre-
existing medical or health condition.

The way you respond to a CO alarm is quite different than a smoke
alarm. That’s because a house fire and a CO problem are two distinctly
different situations. If your smoke alarm were to alarm, you would
quickly be able to judge the level of danger you were in with your sens-
es. You can see and smell the smoke, feel the heat, see, and possibly
hear the fire burning. You can also readily see if your smoke alarm is
alarming in a non-emergency situation. Because your sense of sight,
smell, hearing and touch give you information, you can almost instantly
judge what action to take if you hear your smoke alarm.

2541-7201-01_revB_EN_V1:_  2013.3.5  11:13 AM  Page 3

Содержание KN-COU-B

Страница 1: ...d this user guide which should be saved for future reference and passed on to any subsequent owner Carbon Monoxide Monitor User Guide Model KN COU B Peak Level Memory Digital Display Detects Low Levels of Carbon Monoxide 3 AA Battery Operation 2541 7201 01_revB_EN_V1 _ 2013 3 5 11 13 AM Page 1 ...

Страница 2: ...y Note any combustion equipment not inspected by the technician and consult the manufacturer s instruc tions or contact the manufacturer s directly for more information about CO safety and the equipment Make sure that motor vehicles are not or have not been operating in a garage attached or adja cent to the residence Never restart the source of a CO problem until it has been corrected Never ignore...

Страница 3: ... sensing high levels of CO which can quickly become a dangerous situation This CO monitor operates differently than CO and smoke alarms Like smoke and CO alarms this CO monitor samples the air in your home and sounds a loud alarm to warn you of life threatening conditions In addition this monitor will alert you to lingering low levels of CO below 30 ppm which may have heath implications if you suf...

Страница 4: ...etectable to your senses IMPORTANT This carbon monoxide monitor is designed to detect carbon monoxide from ANY source of combustion It is NOT designed to detect smoke fire or any other gas This carbon monoxide monitor cannot be used to meet code requirements which require the installation of a CO alarm which complies with the alarm requirements set forth in Underwriter s Laboratory standard 2034 U...

Страница 5: ... carbon monoxide monitor requires a continuous supply of electrical power it will not work without power This monitor has been investigated for carbon monoxide detection below 70 PPM Contents of This User Guide 1 Information About Carbon Monoxide 2 Product Features and Specifications 3 Installation Locations 4 Installation Instructions 5 Operating and Monitor Characteristics 6 Maintenance 7 Limite...

Страница 6: ...of the household Mild Exposure Slight headache nausea vomiting fatigue often described as flu like symptoms Medium Exposure Severe throbbing headache drowsiness confusion fast heart rate Extreme Exposure Unconsciousness convulsions cardio respiratory failure death If you experience even mild symptoms of CO poisoning consult your doctor immediately Carbon Monoxide PPM Levels Model KN COU B is equip...

Страница 7: ...ing any fossil fuel such as gasoline propane natural gas oil and wood It can be produced by any fuel burning appliance that is malfunctioning improperly installed or not ventilated correctly such as Automobiles furnaces gas ranges stoves gas clothes dryers water heaters portable fuel burning space heaters and generators fireplaces wood burning stoves and certain swimming pool heaters Blocked chimn...

Страница 8: ...or call your local utility compa ny for assistance Conditions that can Produce Low Background Carbon Monoxide Levels Several studies showed that background concentrations of CO in homes located in urban areas are generally below 17ppm with peaks below 53ppm The background levels of CO in a home can fluctuate depend ing on the time of the day the location with respect to high automobile traffic are...

Страница 9: ...d that the appropriate repairs are made This CO monitor is designed to act as a continuous monitor it is not designed for use as a short term testing device to perform a quick check for the presence of CO CO monitors have limitations Like any other electronic device CO moni tors are not fool proof CO monitors have a limited operational life You must test your CO monitor weekly because it could fai...

Страница 10: ...rite the replace by date ten years from power up in a permanent marker on this label WARNING After ten 10 years from initial power up this monitor will beep two times every 30 seconds and the digital display with show END to indicate that it is time to replace the monitor Replace the monitor immediately It will not detect CO in this condition Two labels have been provided that have important infor...

Страница 11: ... your home install it near bedrooms not in the basement or furnace room This monitor is not a substitute for CO alarms 3 Installation Locations DINING KITCHEN BEDROOM BEDROOM BEDROOM LIVING ROOM Recommended Locations 2 Product Features and Specifications cont Temperature Operating Range 40 F 4 4 C to 100 F 37 8 C Humidity Operating range 10 95 non condensing Audible Alarm 85 dB at 10 3 4 0 5 KHz p...

Страница 12: ... 4 4 C or hotter than 100 F 37 8 C such as crawl spaces attics porches and garages Do not install within 5 ft of heating or cooking appliances Kidde rec ommends 15 ft to prevent nuisance alarms Do not install near vents flues chimneys or any forced unforced air ventilation openings Do not install near ceiling fans doors windows or areas directly exposed to the weather Do not install in dead air sp...

Страница 13: ... the same time you change your clocks for daylight saving time After installing or changing the batteries reinstall your monitor Test your monitor by using the Test Reset button and check that the green Power LED flashes once every 30 seconds Mounting This CO monitor can be either wall mounted or placed on a tabletop For wall mounting follow these steps 1 Remove back mounting plate from the unit p...

Страница 14: ...the start up mode The three 888 will remain for approx imately 10 seconds Then the monitor will display 0 and begin moni toring the air for CO and will continue to do so as long as it receives power This monitor will display a 0 if CO concentrations between 0 and 10 PPM have been detected within the last 15 seconds Whenever the monitor is operating the green Power LED flashes every 30 seconds to i...

Страница 15: ...n a n a 10 No Alert n a n a 20 20 115 115 n a 30 0 55 55 n a 40 0 40 40 475 475 50 0 30 30 175 135 60 0 25 25 115 100 70 0 20 20 60 60 240 80 0 15 15 65 65 90 0 12 12 45 45 100 0 10 10 30 26 150 0 7 5 7 5 21 10 50 250 0 5 5 12 8 PPM of CO Concentration Display Low Level Mid Level CO Alarm Times in Minutes 400 0 4 3 8 4 15 Display CO Concentration in Parts Per Million PPM 2541 7201 01_revB_EN_V1 _ ...

Страница 16: ...Peak Level Memory acti vated Highest concen tration of CO detected is displayed Refer to following sec tion for information regarding Peak Level Memory Brief 888 for approxi mately 10 seconds None Self test when first powered up None CO has not been detected 888 dis played to confirm all segments of display are operational 3 dashes scroll across display 3 to 4 times 4 quick beeps 5 secs silence re...

Страница 17: ...button with the button still pressed press the Test Reset button for two seconds and release The number on the dis play will turn to 0 the memory will be cleared and the alarm will begin monitoring for CO The Peak Level memory is also reset when the unit loses power Carbon Monoxide Monitor Indicator When the monitor senses a life threatening level of CO the unit will emit a loud alarm pattern The ...

Страница 18: ...the monitor Paint will seal the vents and interfere with proper sensor operation Move the CO monitor to a remote location to prevent possible damage or contamination of the sensor prior to performing any of the following Staining or stripping floors or furniture painting or wall papering Using aerosols or adhesives WARNING Reinstall the CO monitor as soon as possible to assure continuous protectio...

Страница 19: ...e exclusion or limitation of consequential or incidental damages so the above limitations or exclusions may not apply to you Legal Remedies This warranty gives you specific legal rights and you may also have other rights that vary from state to state Warranty Performance During the above warranty period your product will be replaced with a comparable product if the defective product is returned in...