background image

4

Installation

Locations to Avoid

• Do not install within 0.9 m (3') of the following: The

door to a kitchen, or a bathroom that contains a tub or
shower, forced air ducts used for heating or cooling,
ceiling or whole house ventilating fans, or other high
air-flow areas.

• Do not place the alarm where drapes or other objects

will block the sensor. Smoke must be able to reach the
sensor to accurately detect conditions.

• Do not install in peaks of vaulted ceilings, “A” frame

ceilings or gabled roofs.

• Install at least 30.5 cm (12") away from fluorescent

lights as electronic noise may cause nuisance alarms.

• Keep out of insect infested areas. Avoid excessively

dusty, dirty or greasy areas. Dust particles may cause
nuisance alarms or failure to alarm.

• Extreme temperatures may effect the sensitivity of the

alarm. Do not install in areas where the temperature is
colder than 4.4°C (40°F) or hotter than 37.8°C (100°F),
such as garages and unfinished attics.

• Do not install in areas where the relative humidity (RH)

is greater than 85%. Very humid areas, with moisture or
steam, can cause nuisance alarms.

• Avoid placing ionization smoke alarms in kitchen areas.

Normal cooking may cause nuisance alarms. If a
kitchen alarm is desired, it should have an alarm silence
feature or be a photoelectric type.

• Do not place in the garage. Particles of combustion are

present when you start your automobile.

• Smoke alarms are not to be used with detector guards

unless the combination (alarm and guard) has been
evaluated and found suitable for that purpose.

Содержание i9010CA

Страница 1: ...e take a few minutes to thoroughly read this user s guide which should be saved for future reference and passed on to any subsequent owner Smoke Alarm User s Guide i9010CA SINGLE STATION SMOKE ALARM 1...

Страница 2: ...ence Teach children how to respond to the alarms and that they should never play with the unit If you have any questions about the operation or installation of your alarm please call our toll free Con...

Страница 3: ...ay prevent the alarm from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it...

Страница 4: ...the room Images 2B and 2C DINING ROOM LIVING ROOM Required Smoke Alarms Ionization Type Smoke Alarm with Hush Control or Photoelectric Type Smoke Alarms for Additional Protection KITCHEN BEDROOM BEDRO...

Страница 5: ...or greasy areas Dust particles may cause nuisance alarms or failure to alarm Extreme temperatures may effect the sensitivity of the alarm Do not install in areas where the temperature is colder than...

Страница 6: ...TANCE FROM PEAK CEILING 10 cm 4 MINIMUM 10 cm 4 MINIMUM 30 5 cm 12 MAXIMUM SIDE WALL BEST PLACEMENT ACCEPTABLE PLACEMENT NEVER HERE S T A G N A N T A I R 0 9 m 3 0 9 m 3 NOT IN THIS AREA ANYWHERE IN T...

Страница 7: ...s shown in Image 3C NOTE This alarm has a battery permanently sealed inside the alarm No battery installation is necessary Activation This model is equipped with a feature that automatically activates...

Страница 8: ...d to present standards extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may create a thermal barrier that can prevent the smoke from...

Страница 9: ...Installation 8 A A IMAGE 3A IMAGE 3B IMAGE 3C IMAGE 3D A LINE ALIGNMENT MARKS SUGGESTED WALL MOUNTING POSITION ROTATE TO MOUNT OR TO REMOVE...

Страница 10: ...moving the unit from the mounting plate The feature engages when the alarm is rotated onto the mounting plate Rotate the alarm onto the mounting plate until you hear the tamper resist tab snap into pl...

Страница 11: ...ting once the alarm is activated see Activation and testing is complete When the smoke alarm ionization sensor chamber senses products of combustion the horn will sound a loud 85db alarm until the sen...

Страница 12: ...e Hush button is extremely useful in a kitchen area or other areas prone to nuisance alarms The Hush feature activated by pushing the Test Hush button on the smoke alarm cover temporarily desensitizes...

Страница 13: ...ED will flash approximately one flash per second The flashing LED and pulsating alarm will continue until the air is cleared Red LED Flashing slowly 1 second on 8 seconds off Indicates that the unit i...

Страница 14: ...test or not operating normally must be replaced with a new alarm Similarly alarms more than 10 years old must be replaced Cleaning the Alarm The alarm should be cleaned at least once a year To clean y...

Страница 15: ...the end of the life of the alarm Replace the alarm when this condition occurs Deactivation WARNING Do not deactivate the alarm until the end of the alarm life when a chirp is heard every 40 45 second...

Страница 16: ...les associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smouldering fires sooner than ionization ala...

Страница 17: ...need an escape ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of fire Determine a place outside your home where you all can meet if a fire occurs Famili...

Страница 18: ...ossible Once outside go to your selected meeting place and make sure everyone is there Call the fire department from your neighbor s home not from yours Don t return to your home until the fire offici...

Страница 19: ...and two family dwelling units approved smoke alarms powered by batteries are permitted Smoke Detection Are More Smoke Alarms Desirable Required number of smoke alarms as shown in Image 1A and Image 1...

Страница 20: ...t apply to this smoke alarm if it has been damaged modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power T...

Отзывы: