WARNING: Please read carefully and thoroughly.

• NFPA 72 states: Life safety from fire in residential

occupancies is based primarily on early notification to
occupants of the need to escape, followed by the
appropriate egress actions by those occupants.

Fire

warning systems for dwelling units are capable of
protecting about half of the occupants in potentially
fatal fires.

Victims are often intimate with the fire, too

old or young, or physically or mentally impaired such
that they cannot escape even when warned early
enough that escape should be possible.

For these

people, other strategies such as protection-in-place or
assisted escape or rescue are necessary.

• Smoke alarms are devices that can provide early

warning of possible fires at a reasonable cost; however,
alarms have sensing limitations.

Ionization sensing

alarms may detect invisible fire particles (associated
with fast flaming fires) sooner than photoelectric alarms.
Photoelectric sensing alarms may detect visible fire
particles (associated with slow smoldering fires) sooner
than ionization alarms.

Home fires develop in different

ways and are often unpredictable.

For maximum

protection, Kidde recommends that both Ionization and
Photoelectric alarms be installed.

• A battery powered alarm must have a battery of the

specified type, in good condition and installed properly.

• AC powered alarms (without battery backup) will not

operate if the AC power has been cut off, such as by an
electrical fire or an open fuse.

• Smoke alarms must be tested regularly to make sure the

batteries and the alarm circuits are in good operating
condition.

• Smoke alarms cannot provide an alarm if smoke does

not reach the alarm.

Therefore, smoke alarms may not

sense fires starting in chimneys, walls, on roofs, on the
other side of a closed door or on a different floor.

• If the alarm is located outside the bedroom or on a

different floor, it may not wake up a sound sleeper.

Fire Safety

17

Содержание i12020ACA

Страница 1: ...193 Rev C 1235 7219 04 SINGLE AND OR MULTIPLE STATION SMOKE ALARM For alarm models Note This alarm has a low battery HUSH feature If the alarm is sounding a low battery warning chirp you can silence t...

Страница 2: ...future reference Teach children how to respond to the alarms and that they should never play with the unit If you have any questions about the operation or installation of your alarm please call our...

Страница 3: ...arms 1235CA 1275CA 1276CA i12020ACA i12040ACA i12060CA PE120CA PI2000CA P12040CA PI2010CA Smoke CO alarms KN COSM IBCA KN COSM ICA CO alarms KN COB ICB CA KN COB IC CA Relay modules 120X SM120X CO120X...

Страница 4: ...t an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the...

Страница 5: ...in 0 9 m 3 of the peak of the ceiling measured horizontally Image 2B 4 Installation DINING ROOM LIVING ROOM Smoke Alarms for Minimum Protection Ionization Type Smoke Alarm with Hush Control or Photoel...

Страница 6: ...sively dusty dirty or greasy areas Dust particles may cause nuisance alarms or failure to alarm Extreme temperatures may effect the sensitivity of the alarm Do not install in areas where the temperatu...

Страница 7: ...allation 6 IMAGE 2A IMAGE 2B HORIZONTAL DISTANCE FROM PEAK CEILING 10 cm 4 MINIMUM 10 cm 4 MINIMUM 30 5 cm 12 MAXIMUM SIDE WALL BEST PLACEMENT ACCEPTABLE PLACEMENT NEVER HERE S T A G N A N T A I R 10...

Страница 8: ...Test your smoke alarm operation after R V or mobile home vehicle has been in storage before each trip and at least once a week during use Wiring CAUTION Turn off the main power to the circuit before w...

Страница 9: ...urer s interconnect system or connection with non specified equipment from another manufacturer into an existing Kidde system could result in nuisance alarming failure to alarm or damage to one or all...

Страница 10: ...2 3 1 WHITE RED BLACK WHITE RED BLACK WHITE RED BLACK Live Neutral Installation 9 IMAGE 3 WIRES ON ALARM HARNESS Black Connected to hot side of AC line White Connected to neutral side of AC line Red C...

Страница 11: ...Installation 10 IMAGE 4A IMAGE 4B ROTATE TO MOUNT OR TO REMOVE IMAGE 4C BATTERY REMINDER TAB IMAGE 4D TAMPER RESIST LOCKING PIN...

Страница 12: ...battery the battery door will not close and the unit will not attach to the mounting plate Plug the AC Quick Connect wire harness into the back of the alarm Image 5 making sure that the locks on the c...

Страница 13: ...models Confirm unit operation by pressing the Test button again The smoke alarm is operating once AC power is applied a fresh battery is installed only for battery backup models i12040ACA and PE120CA...

Страница 14: ...he alarm The smoke alarm is desensitized by pushing the TEST HUSH button on the smoke alarm cover If the smoke is not too dense the alarm will silence immediately The red LED will illuminate for 1 5 s...

Страница 15: ...inating unit will flash All other units in the interconnect system will sound an alarm but their red LED s will NOT flash Alarm Memory Models i12020ACA and i12040ACA only This smoke alarm is equipped...

Страница 16: ...rials and start a fire Test the alarm weekly to ensure proper operation Erratic or low sound coming from your alarm may indicate a defective alarm and it should be returned for service see Warranty se...

Страница 17: ...Duracell MN1604 or MX1604 Gold Peak 1604A Panasonic 6AM6 6AM 6 6AM 6PI 6AM6X and 6LR61 GA Lithium Type Ultralife U9VL J These batteries can be purchased at your local retailer WARNING Use only the ba...

Страница 18: ...associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms H...

Страница 19: ...pe ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of fire Determine a place outside your home where you all can meet if a fire occurs Familiarize everyon...

Страница 20: ...our neighbor s home not from yours Don t return to your home until the fire officials say that it is all right to do so There are situations where a smoke alarm may not be effective to protect against...

Страница 21: ...tteries are permitted Smoke Detection Are More Smoke Alarms Desirable Required number of smoke alarms as shown in Image 1A and Image 1B The required number of smoke alarms might not provide reliable e...

Страница 22: ...modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power The liability of Kidde or any of its parent or subsi...

Отзывы: