background image

16

Maintenance

Battery Replacement

Models

i12040ACA

and

PE120CA

These alarms have a low/missing battery monitor circuit
which will cause the alarm to “chirp” approximately every
30-40 seconds for a minimum of seven (7) days when the
battery gets low.

Replace the battery when this condition

occurs.

Models

i12040ACA

and

PE120CA

use a 9 V carbon zinc

battery (alkaline and lithium batteries may also be used).
A fresh battery should last for one year under normal
operating conditions.

Use only the following 9 volt batteries for replacement:

Carbon-Zinc Type

Eveready 1222
Gold Peak 1604P or 1604S

Alkaline Type

Energizer 522
Duracell MN1604 or MX1604
Gold Peak 1604A
Panasonic 6AM6, 6AM-6, 6AM-6PI,

6AM6X and 6LR61 (GA)

Lithium Type

Ultralife U9VL-J

These batteries can be purchased at your local retailer.

WARNING! Use only the batteries specified above. Use of different
batteries than the recommended ones, may have a detrimental effect on
the smoke alarm. A good safety measure is to replace the battery at least
once a year, or at the same time you change your clocks for daylight
saving time. Be sure to follow the battery installation instructions printed
on the back of the alarm.

SMOKE SENSING CHAMBER OPERATION: THIS ALARM WILL “CHIRP” IF
ABNORMAL OPERATION OF THE SMOKE-SENSING CHAMBER IS
DETECTED. THIS CHIRP WILL OCCUR APPROXIMATELY 20 SECONDS
AFTER THE RED LED FLASH. REPLACE THE ALARM IF THIS CONDITION
OCCURS.

NOTE: WEEKLY TESTING IS REQUIRED!

Содержание i12020ACA

Страница 1: ...193 Rev C 1235 7219 04 SINGLE AND OR MULTIPLE STATION SMOKE ALARM For alarm models Note This alarm has a low battery HUSH feature If the alarm is sounding a low battery warning chirp you can silence t...

Страница 2: ...future reference Teach children how to respond to the alarms and that they should never play with the unit If you have any questions about the operation or installation of your alarm please call our...

Страница 3: ...arms 1235CA 1275CA 1276CA i12020ACA i12040ACA i12060CA PE120CA PI2000CA P12040CA PI2010CA Smoke CO alarms KN COSM IBCA KN COSM ICA CO alarms KN COB ICB CA KN COB IC CA Relay modules 120X SM120X CO120X...

Страница 4: ...t an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the...

Страница 5: ...in 0 9 m 3 of the peak of the ceiling measured horizontally Image 2B 4 Installation DINING ROOM LIVING ROOM Smoke Alarms for Minimum Protection Ionization Type Smoke Alarm with Hush Control or Photoel...

Страница 6: ...sively dusty dirty or greasy areas Dust particles may cause nuisance alarms or failure to alarm Extreme temperatures may effect the sensitivity of the alarm Do not install in areas where the temperatu...

Страница 7: ...allation 6 IMAGE 2A IMAGE 2B HORIZONTAL DISTANCE FROM PEAK CEILING 10 cm 4 MINIMUM 10 cm 4 MINIMUM 30 5 cm 12 MAXIMUM SIDE WALL BEST PLACEMENT ACCEPTABLE PLACEMENT NEVER HERE S T A G N A N T A I R 10...

Страница 8: ...Test your smoke alarm operation after R V or mobile home vehicle has been in storage before each trip and at least once a week during use Wiring CAUTION Turn off the main power to the circuit before w...

Страница 9: ...urer s interconnect system or connection with non specified equipment from another manufacturer into an existing Kidde system could result in nuisance alarming failure to alarm or damage to one or all...

Страница 10: ...2 3 1 WHITE RED BLACK WHITE RED BLACK WHITE RED BLACK Live Neutral Installation 9 IMAGE 3 WIRES ON ALARM HARNESS Black Connected to hot side of AC line White Connected to neutral side of AC line Red C...

Страница 11: ...Installation 10 IMAGE 4A IMAGE 4B ROTATE TO MOUNT OR TO REMOVE IMAGE 4C BATTERY REMINDER TAB IMAGE 4D TAMPER RESIST LOCKING PIN...

Страница 12: ...battery the battery door will not close and the unit will not attach to the mounting plate Plug the AC Quick Connect wire harness into the back of the alarm Image 5 making sure that the locks on the c...

Страница 13: ...models Confirm unit operation by pressing the Test button again The smoke alarm is operating once AC power is applied a fresh battery is installed only for battery backup models i12040ACA and PE120CA...

Страница 14: ...he alarm The smoke alarm is desensitized by pushing the TEST HUSH button on the smoke alarm cover If the smoke is not too dense the alarm will silence immediately The red LED will illuminate for 1 5 s...

Страница 15: ...inating unit will flash All other units in the interconnect system will sound an alarm but their red LED s will NOT flash Alarm Memory Models i12020ACA and i12040ACA only This smoke alarm is equipped...

Страница 16: ...rials and start a fire Test the alarm weekly to ensure proper operation Erratic or low sound coming from your alarm may indicate a defective alarm and it should be returned for service see Warranty se...

Страница 17: ...Duracell MN1604 or MX1604 Gold Peak 1604A Panasonic 6AM6 6AM 6 6AM 6PI 6AM6X and 6LR61 GA Lithium Type Ultralife U9VL J These batteries can be purchased at your local retailer WARNING Use only the ba...

Страница 18: ...associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms H...

Страница 19: ...pe ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of fire Determine a place outside your home where you all can meet if a fire occurs Familiarize everyon...

Страница 20: ...our neighbor s home not from yours Don t return to your home until the fire officials say that it is all right to do so There are situations where a smoke alarm may not be effective to protect against...

Страница 21: ...tteries are permitted Smoke Detection Are More Smoke Alarms Desirable Required number of smoke alarms as shown in Image 1A and Image 1B The required number of smoke alarms might not provide reliable e...

Страница 22: ...modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power The liability of Kidde or any of its parent or subsi...

Отзывы: