background image

2. Product Features and Specifications

End of Life Notification

IMPORTANT: Ten (10) years after unit is first powered, this alarm will
chirp two times every 30 seconds to indicate it is time to replace the
alarm.

End of Life “Hush”: This model has an End of Life Hush feature which
allows you to press the test/reset button on the alarm and disable the
“chirps” for a period of 3 days. This gives you a chance to replace the
alarm at a more convenient time while still providing protection. The two
chirps will repeat again every 3 days and can be reset a total of 30 days.
After 30 days, the End of Life signal cannot be “Hushed.” The alarm
must be replaced.

During this End of Life HUSH period, your alarm is monitoring for CO.

To help identify the date to replace the alarm, a label has been affixed to
the side of the alarm. Write the “replace by” date (ten years from power
up) in a permanent marker on this label.

Temperature:

Operating Range: 40°F (4.4°C) to 100°F (37.8°C)

Humidity:

Operating range: 10-95% non-condensing

Audible Alarm:

85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm

Sensor:

Electrochemical

Power:

120 volts AC, 60 Hz, 90 mA max, 2AA battery back-up

Alarm Response Times:

70 PPM = 60-240 min., 150 PPM = 10-50 min., 400 PPM = 4-15 min.

2546-7201-00(KN-COB-DP2)_V3a.qxd:_  2014.4.8  9:52 AM  Page 10

Содержание 21029713

Страница 1: ...this user guide which should be saved for future reference and passed on to any subsequent owner Carbon Monoxide Alarm User Guide Models KN COB DP2 KN COB DP2 120V AC Plug In 2 AA battery Tamper Resis...

Страница 2: ...uip ment serviced immediately Note any combustion equipment not inspected by the technician and consult the manufacturer s instruc tions or contact the manufacturer s directly for more information abo...

Страница 3: ...emergency situation Because your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if you hear your smoke alarm CO is an invisible odorles...

Страница 4: ...ute effects of carbon monoxide exposure It may not fully safe guard individuals with specific medical conditions If in doubt consult a medical practitioner Individuals with medical problems may consid...

Страница 5: ...while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young children and household pets...

Страница 6: ...or closed garage attached or near a home Burning charcoal or fuel in grills and hibachis in an enclosed area Conditions That Can Produce Carbon Monoxide The following conditions can result in transie...

Страница 7: ...It does not prevent CO from occurring nor can it solve an existing CO problem If your unit has alarmed and you ve provided ventilation by leaving your windows and doors open the CO buildup may have d...

Страница 8: ...home and not reach a CO alarm installed on a different level For example CO in the basement may not reach an alarm on the second level near the bedrooms For these reasons we recommend you provide com...

Страница 9: ...d for the CO alarm to function properly The Tamper Resist feature is a constant 85dB alert to indicate the unit has been unplugged or has come loose from the outlet THIS FEATURE IS INI TIALLY DISABLED...

Страница 10: ...nd can be reset a total of 30 days After 30 days the End of Life signal cannot be Hushed The alarm must be replaced During this End of Life HUSH period your alarm is monitoring for CO To help identify...

Страница 11: ...rches and garages Do not install within 5 ft of heating or cooking appliances Kidde recommends 15 ft to prevent nuisance alarms Do not install near vents flues chimneys or any forced unforced air vent...

Страница 12: ...ee Tamper Resist Feature details in the Product Features and Specifications section 5 Pull the yellow tab to activate the battery backup 6 Plug the alarm into the outlet Important Labels Provided Two...

Страница 13: ...tored the alarm will automatically switch back to normal operating mode and the green LED will come on continu ously When the CO alarm is unplugged If the tamper resist feature is ON and the unit is u...

Страница 14: ...replacement Alkaline batteries Energizer E91 Duracell MN1500 MX1500 Gold Peak 15A Golden Power GLR6A Replace the battery door Error serv ice alarm Red LED flashes every 30 seconds One quick beep every...

Страница 15: ...children of the dangers of CO poisoning Never use detergents or solvents to clean the alarm Chemicals can permanently damage or temporarily contaminate the sensor Avoid spraying air fresheners hair s...

Страница 16: ...unications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be d...

Страница 17: ...clusion or limitation of consequential or incidental damages so the above limitations or exclusions may not apply to you Legal Remedies This warranty gives you specific legal rights and you may also h...

Отзывы: