23
WArnIng: FAIlUre to properly InStAll And ACtIVAte tHIS AlArM WIll preVent proper
operAtIon oF tHIS AlArM And WIll preVent ItS reSponSe to FIre HAzArdS.
Interconnect Capability
This model has AC hardwire AND wireless alarm interconnect capability. When one hardwire or wireless interconnect
unit sounds an alarm, all other compatible hardwire or wireless interconnected units will also alarm.
AC Hardwire Interconnect Model Compatibility
•
The following models can be interconnected using the standard AC wiring interconnect: 1235, 1275, 1276, 1285,
i12020, i12020A, i12040, i12040A, i12060, i12060A, i12080, i12080A, i4618, i4618A, i4618AC, KN-SMFM-I,
RF-SM-ACDC, PE120, P12040, Pi2000, Pi2010, KN-COSM-I, KN-COSM-IB, KN-COSM-IBA, KN-COPE-I,
KN-COPE-IC, KN-COB-IC, KN-COP-IC, SL177i, SLED177i, HD135F, SM120X, CO120X, i12010S, i12010SCO,
P4010ACSCO, P4010ACSCO-W, P4010LACS-W, P4010ACS, P4010ACS-W.
Wireless alarm Interconnect Model Compatibility
•
The following models can be interconnected using wireless interconnect.
AC Models:
P4010ACSCO-W, P4010LACS-W, P4010ACS-W.
DC Models:
P4010LDCS-W, P4010DCS-W, P4010DCSCO-W
•
Maximum distance between wireless interconnect models is greater than 300 feet in open air.
11. Operation and Testing
operation
The alarm is operating once it is activated and testing
is complete. When products of combustion (smoke or
CO) are sensed, the unit sounds a loud alarm with voice
messages. See Sections 1 and 2 for alarm signal descriptions.
In high levels of CO, the unit will go into alarm in a shorter period of time than at low levels of CO.
Co AlArM SenSor reSponSe tIMeS
At 70 PPM, the unit must alarm within 60-240 minutes.
At 150 PPM, the unit must alarm within 10-50 minutes.
At 400 PPM, the unit must alarm within 4-15 minutes.