   10.5 Load Modes

LOAD

OFF

<Mode>

Manual

Load mode setting icon

Load state

Load mode

1)  If the characters above the “<mode>” are on, it indicates that the load is switched on and 

off indicates it is switched off

2)  Tap the ok key to enter into load setting parameter and below the “<mode>” the display 

will flash use the up down keys to select any of the load modes then tap ok to confirm 

setting.

3)  Press and hold ok in any menu but not in setting mode: if the current mode is “manual’ 

mode pressing and holding the key will switch the load on and off. If the current load 

mode is not manual mode pressing and holding the ok key will cause the display to skip 

to the load mode setting interface and a reminder will pop up telling the user in this 

mode, pressing and holding the key will not switch on/off the load.

4)  Note: this parameter is ineffective for controllers without loads.

Load mode

Mode 

characters

Description

Sole light 
control mode

Light

+

On

Light control 
+ time 
control mode
1 to 14H

Light

+

01H

...

Light

+

14 H

Manual 
mode

Manual

Debugging 
mode

Debug

Normal on 
mode

Normal On

The solar panel voltage is lower than the light control on voltage, and after a 
preset time delay , the controller will switch on the load;
The solar panel voltage is higher than the light control off voltage, and after 
a preset time delay , the controller will switch off the load.

The solar panel voltage is lower than the light control on voltage, and after a 
time delay, the controller will switch on the load. From this point on, the load 
will work for a preset period of time (1 to 14 hours) before being switched off.

In this mode, whether it's day or night, users can press and hold the "OK" 
key to switch on or off the load; this mode is often used in some special 
occasions or during commissioning.

As long as the solar panel voltage is lower than the light control on voltage, 
the controller will immediately switch on the load;
As soon as the solar panel voltage gets higher than the light control off 
voltage, the controller will immediately switch off the load.
This mode is usually used during system installation and commissioning.

This mode is suitable for applications requiring 24-hour operation, and after 
being switched on, the load keeps outputting in this mode.

Including total charging amp-hrs, total discharging amp-hrs, total power consumption, numbers of 
operating days, over-discharges and full-charges 

ANALYSI

TOTAL

DAYS:  9
LVDC :

5

Number of operating days: 9

Number of over-discharges:5

Statistics icon 

   10.6 Static Data

Содержание KAMPPTRC

Страница 1: ...KAMPPTRC REMOTE METER USER MANUAL KAMPPTRC ...

Страница 2: ...arging and discharging parameters load stat fault codes historical data and device information 2 setting of related charging and discharging parameters 3 Load mode setting load on off switching manual mode 4 Built in bluetooth 1 carefully read all instructions and precautions in this manual to insure correct use of controller 2 This controller is only to be used with the KickAss mppt regulator 3 T...

Страница 3: ...2x103 82mm Installation hole diameter 3 5 mm Front Right view External dimensions 118 5 118 5 48mm Installation dimensions 50 50mm or 70 70mm Installation hole diameter 5 mm 5 2 Installation on a wall 5 INSTALLATION INSTRUCTIONS 5 1 Installation on a controller case or panel ...

Страница 4: ...enu tap the key to return to the previous level until the main menu is reached 2 In the setting mode a tap on this key can cancel the data modification in process and exit the setting mode In any menu press and hold the key to immediately skip to the error code page for convenient checkup 1 In a menu which contains submenus tap the key to enter into a submenu 2 In a menu with settable or adjustabl...

Страница 5: ...ler is normal Slow flashing Communication connection between the LCD display unit and controller abnormality When the startup screen is displayed tap any key to skip it If no operation is detected within 5 seconds a Connecting interface will ensue Connecting interface When connection is successfully done the main menu will appear Solar Controller Connecting 9 FAULT INDICATION AND COMMUNICATION IND...

Страница 6: ...torical data of the current day Device information Bluetooth connection state This menu is available only to the display units with the optional bluetooth function Refer to Usage of Navigation Keys for operations including entering into and exiting each of the above menus related parameters setting etc ...

Страница 7: ... a dynamic arrow indicate the load is switched on A bulb shown as left and a static arrow indicate the load is switched off Overload or short circuit protection Day or night indicating icon Charging current icon Battery icon and SOC Load current icon Load icon and state indication charging power load current Battery voltage 37 26 8V 11 6V 0W 0A OFF 0A 37 Related to charging Related to battery Rela...

Страница 8: ...g charging time Equ Time 0 300 MIN 1 Boost charging time Bst Time 0 300 MIN 1 5 Equalizing charging interval Equ Inv 0 30 D days 1 Temperature compensation Temp Com 3 5 mV 2V 1 Light control time L CON T 0 60 MIN 1 Light control voltage L CON V 5 11V n 1 6 LCD screen backlight time BackLight T 1 Fault voice alarm Voice Alarm Clear historical data ClrHistoryData Reset to factory settings Restore De...

Страница 9: ... will be constantly lit and the range for backlight time will be 1 to 600 seconds Tap ok to confirm settings 10 4 3 controller Abnormality Voice Alarm On off Setting Displayed item parameter Description Voice Alarm ON Voice alarm enabled Voice Alarm OFF Voice alarm disabled Alarm type No Alarm System running well or wa Alarming 1min Battery over discharge Load short circuit overload controller or b...

Страница 10: ... preset time delay the controller will switch on the load The solar panel voltage is higher than the light control off voltage and after a preset time delay the controller will switch off the load The solar panel voltage is lower than the light control on voltage and after a time delay the controller will switch on the load From this point on the load will work for a preset period of time 1 to 14 ...

Страница 11: ...ol 0A 2 MaxChgPow 0W MaxLodPow 0W C D Chg 0AH C D Lod 0AH 3 E D Chg 0kWh E D Lod 0kWh 1 Xxxx select the historical data of day xxxx counting backwards 0000 the current day 0001 yesterday 0002 the day before yesterday The selected day s min battery voltage The selected day s max battery voltage The selected day s max charging current The selected day s max discharging current The selected day s max...

Страница 12: ... device is invisible to the mobile App s search Check whether it has been paired with some other mobile phone Note this menu is only available to the display units with the optional bluetooth function Code 1 1 24 01469 Symptoms Causes and solutions Model 4845 HW ver 00 02 07 SW ver 00 00 04 Serial 160300032 10 9 Bluetooth connection status BLE STATUS Connected Bluetooth icon Indicating a bluetooth...

Отзывы: