6-4 Setting Inverter Parameters:
5
0
1
v
BATT
01
~
100%
1. Press "SET/OK" for 5s. You are now entering the settings interface. As shown above.
2. Press "UP and DOWN" to adjust parameters.
3. Press "SET/OK" to confirm adjustment.
4. To reset the parameters press "set" and the ICON 1 will flash.
5. Pressing "ESC" will cancel this step and redirect you too the setting interface.
6. Press and hold "ESC" for 5s to exit the settings interface.
7. If there is no activity for 10s the inverter display will go back to the main menu.
Setting interface
Undervoltage protection value
Undervoltage recovery value
Overvoltage protection value
Overvoltage recovery value
Overload Short Circuit Mode
Overload setting value
Overload Short Circuit Restart Delay Value
Code
Range
01
02
03
04
05
06
07
Default
:
0 Setting 0: lock 1:restart
Default
:
110% Setting
:
105-120%
Default
:
10 Setting: 5-60S
Default
:
0
Setting 0:Open 1:Close
08
Alarming mode
Notes
:
Undervoltage warning value = undervoltage closing value + 0.5V, overvoltage warning value = overvoltage
closing value - 0.5V.
12V Default
:
14.7 Setting
:
14.5-15.0
12V Default
:
10.5 Setting
:
10.0-11.0
12V Default
:
12.0 Setting
:
11.5-12.5
12V Default
:
15.3 Setting
:
15.2-16.0