FEC

 – Use the Scroll Up/Down button to select FEC. Press the OK button to enter the FEC

menu. The FEC is set for 7/8 only. Press the OK button to set.

GUARD INTERVAL

 – Use the Scroll Up/Down button to select GUARD INTERVAL. Press

the OK button to enter the GUARD INTERVAL menu.

 

The  GUARD INTERVAL is set for

1/32 only. Press the OK button to set.

OFDM  MODE

  –Use  the  Scroll  Up/Down  button  to  select  OFDM  MODE.  Press  the  OK

button to enter the OFDM MODE menu. Menu options are 2K, 8K. The factory default is 8K.
Use the Scroll Up/Down button to select the desired OFDM MODE and press the OK button
to set.

RF Output

 – Use the Scroll Up/Down button to select RF Output. Press the OK button to

enter the RF Output menu. Menu options are Normal, Inverted and C.W. The factory default
is Normal. Use the Scroll Up/Down button to select the desired RF Output and press the OK
button to set.

Brightness

 – Use the Scroll Up/Down button to select Brightness. Press the OK button to

enter the Brightness menu. Use the Scroll Up/Down button to select the desired Brightness
value (0 to 255) and press the OK button to set. Factory default is 128

Contrast

 – Use the Scroll Up/Down button to select Contrast. Press the OK button to enter

the Contrast menu. Use the Scroll Up/Down button to select the desired Contrast value (0 to
255) and press the OK button to set. Factory default is 128.

Saturation

 – Use the Scroll Up/Down button to select Saturation. Press the OK button to

enter the Saturation menu. Use the Scroll Up/Down button to select the desired Saturation
value (0 to 255) and press the OK button to set. Factory default is 128.

Hue

 – Use the Scroll Up/Down button to select Hue. Press the OK button to enter the Hue

menu. Use the Scroll Up/Down button to select the desired Hue value (0 to 255) and press
the OK button to set. Factory default is 128.

Device Address

 – Use the Scroll Up/Down button to select Device Address. Press the OK

button to enter the Device Address menu. Use the Scroll Up/Down to select the Desired
Address ranging from 1 to 255  then press the OK button to set. 

Setting the Device address to 0 will clear and reset any Network Parameters (Host
Name, Revert to DHCP, IP Address, and MAC address) back to factory default settin

All previous settings will be lost if 0 is selected.

CELL ID

 –Use the Scroll Up/Down button to select CELL ID. Press the OK button to enter

the CELL ID menu. Use the Scroll Up/Down button to select the desired CELL ID ranging
from 0 to 65535 then press the OK button to set. Factory default is 0.

Stream ID

 – Use the Scroll Up/Down button to select Stream ID. Press the OK button to

enter the Stream ID menu. Use the Scroll Up/Down button to select the desired Stream ID
ranging from 0 to 65535 then press the OK button to set. Factory default is 1000.

Network ID

 – Use the Scroll Up/Down button to select Network ID. Press the OK button to

enter the Network ID menu. Use the Scroll Up/Down button to select the desired Network ID
ranging from 0 to 65535 then press the OK button to set. Factory default is 100.

ORG Network ID

 – Use the Scroll Up/Down button to select ORG Network ID. Press the

OK button to enter the ORG Network ID menu. Use the Scroll Up/Down button to select the
desired ID ranging from 0 to 65535 then press the OK button to set. Factory default is 10.

                                                                                                                              

HDM-1000/2000/4000  Manual V1.0

10

Содержание HDM-1000

Страница 1: ...INSTALLATION CONFIGURATION MANUAL HDM 1000 HDM 2000 HDM 4000 DVB T HD Series Single Dual Quad Input Digital Modulators...

Страница 2: ...DM 2000 6 HDM 4000 6 HARDWARE INSTALLATION and CONNECTIONS 7 MODULATOR SETUP AND CONFIGURATION 9 INITIAL SETUP TO FACTORY DEFAULT 9 MODULATOR CONFIGURATION 9 Procedure to connect to the Encoder via th...

Страница 3: ...rated power supply with the center pin positive The use of any other power supply could cause damage and invalidate the manufacturer s warranty DO NOT connect the power cord to the device if the powe...

Страница 4: ...o signals to a COFDM QAM RF output The HDM 1000 HDM 2000 HDM 4000 offer a single dual or quad intelligent input All units feature programmable channel and network names Adjustable logic channel number...

Страница 5: ...um 33dB typical MODULATION Video Resolution Video Compression MPEG2 MP HL AVC MP Level4 AVC MP Level4 Audio Compression LCN Yes Carrier OFDM Mode 2K 8K Guard Intervals 1 32 Code Rate FEC 7 8 7 8 7 8 C...

Страница 6: ...shipped factory tested Ensure all items are removed from the container prior to discarding any packing material Thoroughly inspect the unit for shipping damage with particular attention to connectors...

Страница 7: ...put ports If using a Composite Video source use a 75 coaxial cable with RCA connectors to connect the video source e g CATV DVD VCR Camera to the unit s yellow RCA VIDEO INPUT CVBS port jack IN1 IN2 d...

Страница 8: ...he unit s inputs IN1 IN2 depending on the HD model Use a quality 75 coaxial cable with F connectors from the unit s RF OUT jack to the distribution system combiner or reverse splitter or directly to a...

Страница 9: ...nce the correct password is entered press the OK button and the LCD Screen will display Advanced Menu Output Channel The following configuration options are available under Advanced Menu Output Channe...

Страница 10: ...s the OK button to set Factory default is 128 Hue Use the Scroll Up Down button to select Hue Press the OK button to enter the Hue menu Use the Scroll Up Down button to select the desired Hue value 0...

Страница 11: ...1 Program Num option ranging from 0 to 65535 then press the OK button to set Factory default is 1001 If the modulator has more than one video input scroll through the Advanced Menu for the additional...

Страница 12: ...o Output Press the OK button to enter the Audio Output menu Use the Scroll Up Down button to select the Audio Output option MPEG2 Layer I MP2 AAC AC 3 Pass Through The factory default is MP2 Press the...

Страница 13: ...der being installed in the system Device Address ranges from 1 255 Warning Setting the DEVICE ADDRESS to 0 will clear the network setting to the Factory Default value 6 Connect each encoder using a st...

Страница 14: ...t plane 9 Select Local Area Connection Icon Then Right Click Select Properties Internet Protocol Version 4 TCP IPv4 Properties 10 Select Obtain an IP address automatically Obtain DNS server address au...

Страница 15: ...rt Computer Network 12 After selecting Network the encoders will show up on the right side under Media Devices Each device will show up by Device Address KH001 002 003 Right Click on the icon for the...

Страница 16: ...will be presented with encoders Authentication Required screen 15 Enter User Name and Password User Name admin Password Admin123 16 Change settings of the encoder via the Common Setup Encoder Setup N...

Страница 17: ...r as unit reboots and save the changes After the encoder recovers from rebooting we recommend you save backup the configuration file for each encoder 20 Select Administration Tab then Backup A config...

Страница 18: ...coders via the internet will require a VPN device with a Static IP 1 Using the instructions located in Procedure to connect to the Encoder via the remote setup port enter a unique Device Address for e...

Страница 19: ...Static IP Required connected to the internet Contact your network administrator for the VPN device setup 10 Establish a VPN connection from a PC or laptop from an external internet connection 11 Once...

Страница 20: ...le UPnP in Windows 7 Control Panel Locate Icon for Network and Sharing Center Click Change Advanced sharing settings located on the top left side Select Turn on network discovery located under Network...

Страница 21: ...ick Details 3 Click to select the Internet Gateway Device and UPnP User Interface check boxes in the Subcomponents of Networking Services window if they are not selected 4 Follow the instructions that...

Страница 22: ...n click Start under Service status Then close the SSDP Discovery Services Properties dialog box After you follow these steps the SSDP Discovery Service is running and will automatically start when you...

Страница 23: ...HD MODULATOR NOTES PRODUCT NOTES ITEM VALUE PASSWORD SERIAL NUMBER INSTALLATION DATE PURCHASE DATE VIDEO 1 INPUT VIDEO 2 INPUT VIDEO 3 INPUT VIDEO 4 INPUT HDM 1000 2000 4000 Manual V1 0 23...