FEC
– Use the Scroll Up/Down button to select FEC. Press the OK button to enter the FEC
menu. The FEC is set for 7/8 only. Press the OK button to set.
GUARD INTERVAL
– Use the Scroll Up/Down button to select GUARD INTERVAL. Press
the OK button to enter the GUARD INTERVAL menu.
The GUARD INTERVAL is set for
1/32 only. Press the OK button to set.
OFDM MODE
–Use the Scroll Up/Down button to select OFDM MODE. Press the OK
button to enter the OFDM MODE menu. Menu options are 2K, 8K. The factory default is 8K.
Use the Scroll Up/Down button to select the desired OFDM MODE and press the OK button
to set.
RF Output
– Use the Scroll Up/Down button to select RF Output. Press the OK button to
enter the RF Output menu. Menu options are Normal, Inverted and C.W. The factory default
is Normal. Use the Scroll Up/Down button to select the desired RF Output and press the OK
button to set.
Brightness
– Use the Scroll Up/Down button to select Brightness. Press the OK button to
enter the Brightness menu. Use the Scroll Up/Down button to select the desired Brightness
value (0 to 255) and press the OK button to set. Factory default is 128
Contrast
– Use the Scroll Up/Down button to select Contrast. Press the OK button to enter
the Contrast menu. Use the Scroll Up/Down button to select the desired Contrast value (0 to
255) and press the OK button to set. Factory default is 128.
Saturation
– Use the Scroll Up/Down button to select Saturation. Press the OK button to
enter the Saturation menu. Use the Scroll Up/Down button to select the desired Saturation
value (0 to 255) and press the OK button to set. Factory default is 128.
Hue
– Use the Scroll Up/Down button to select Hue. Press the OK button to enter the Hue
menu. Use the Scroll Up/Down button to select the desired Hue value (0 to 255) and press
the OK button to set. Factory default is 128.
Device Address
– Use the Scroll Up/Down button to select Device Address. Press the OK
button to enter the Device Address menu. Use the Scroll Up/Down to select the Desired
Address ranging from 1 to 255 then press the OK button to set.
Setting the Device address to 0 will clear and reset any Network Parameters (Host
Name, Revert to DHCP, IP Address, and MAC address) back to factory default settin
All previous settings will be lost if 0 is selected.
CELL ID
–Use the Scroll Up/Down button to select CELL ID. Press the OK button to enter
the CELL ID menu. Use the Scroll Up/Down button to select the desired CELL ID ranging
from 0 to 65535 then press the OK button to set. Factory default is 0.
Stream ID
– Use the Scroll Up/Down button to select Stream ID. Press the OK button to
enter the Stream ID menu. Use the Scroll Up/Down button to select the desired Stream ID
ranging from 0 to 65535 then press the OK button to set. Factory default is 1000.
Network ID
– Use the Scroll Up/Down button to select Network ID. Press the OK button to
enter the Network ID menu. Use the Scroll Up/Down button to select the desired Network ID
ranging from 0 to 65535 then press the OK button to set. Factory default is 100.
ORG Network ID
– Use the Scroll Up/Down button to select ORG Network ID. Press the
OK button to enter the ORG Network ID menu. Use the Scroll Up/Down button to select the
desired ID ranging from 0 to 65535 then press the OK button to set. Factory default is 10.
HDM-1000/2000/4000 Manual V1.0
10