Zero Clearance Stove
5
VENT TEMINATOR LOCATION
Vent terminator may not be located:
1.
Less than 1 foot above grade.
2.
Above or within 3 feet horizontally of oil tank or gas meter.
3.
Closer than 3 feet to inside corner of home.
4.
Closer than 1 foot from any opening that gasses could re-enter home.
5.
Less than 4 feet below windows.
6.
Less than 1 foot horizontally of door or window.
7.
Less than 3 feet above any forced air inlet located within 10 feet.
8.
Less than 7 feet above grade when adjacent to public walkways.
Direct Vent Completion Kit
1.
Exhaust motor
2.
Exhaust system
3.
4 inch stainless steel pipe
4.
6 inch cap
5.
Inside plate
6.
6 inch 24 gauge black pipe
7.
Outside Plate
8.
4 inch Tee
9.
4 inch Chimney cap