- This feature can be activated from the remote control ONLY. Activating SLEEP
feature will increase the selected temperature by 1°C/1°F after 30 minutes. The
temperature will again increase (cooling) by another 1°C/1°F after an additional 30
minutes. This new temperature will be maintained for 7 hours before returning to the
originally selected temperature. This ends the Sleep/Eco mode and the unit will
continue to operate as originally programmed.
NOTE: This feature is unavailable in FAN or DRY mode.
shuts
power outage
After the unit has stopped, it cannot be restarted until 3 minutes time has elapsed.
- During dehumidifying modes, remove the drain plug
from the back of the unit, install the drain connector
(5/8" universal female mender) with a 3/4" hose (locally
purchased). For the models without a drain connector,
just attach the drain hose to the hole. Place the open
end of the hose directly over the drain area in your
basement floor.
This is to protect the unit. Operation will automatically start after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
- The louver can be set to the desired position manually.
- Do not place any heavy objects or other loads on the louver, doing so will cause
damage to the unit.
- Keep the louver fully opened during operation.
Remove the
drain plug
Continuous
drain hose
WATER DRAINAGE
Bottom
drain plug
- When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times, the
digital display area shows "P1". At this time the air
conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate (this is normal). Carefully move
the unit to a drain location, remove the bottom drain
plug and let the water drain away. Reinstall the
bottom drain plug and restart the machine until the
"P1" symbol disappears. If the error repeats, call for
service.
NOTE: Make sure the hose is secure so there are
no leaks. Direct the hose toward the drain, making
sure that there are no kinks that will stop the water
flowing. Place the end of the hose into the drain and
make sure the end of the hose is down to let the
water flow smoothly. When the continuous drain
hose is not used, ensure that the drain plug and knob
are installed firmly to prevent leakage.
NOTE: Be sure to reinstall the bottom drain plug
firmly to prevent leakage before using the unit.
SLEEP/ECO operation