background image

- This feature can be activated from the remote control ONLY. Activating SLEEP 

  feature will increase the selected temperature by 1°C/1°F after 30 minutes. The 

  temperature will again increase (cooling) by another 1°C/1°F after an additional 30

  minutes. This new temperature will be maintained for 7 hours before returning to the 

  originally selected temperature. This ends the Sleep/Eco mode and the unit will 

  continue to operate as originally programmed.

  NOTE: This feature is unavailable in FAN or DRY mode.

shuts

power outage

 After the unit has stopped, it cannot be restarted until 3 minutes time has elapsed.

- During dehumidifying modes, remove the drain plug

  from the back of the unit, install the drain connector

  (5/8" universal female mender) with a 3/4" hose (locally

  purchased). For the models without a drain connector,

  just attach the drain hose to the hole. Place the open

  end of the hose directly over the drain area in your

  basement floor.

This is to protect the unit. Operation will automatically start after 3 minutes.

AIR FLOW DIRECTION ADJUSTMENT

- The louver can be set to the desired position manually. 

- Do not place any heavy objects or other loads on the louver, doing so will cause 

  damage to the unit.

- Keep the louver fully opened during operation.

Remove the 

drain plug

Continuous 

drain hose

WATER DRAINAGE

Bottom 

drain plug 

- When the water level of the bottom tray reaches a

  predetermined level, the unit beeps 8 times, the

  digital display area shows "P1". At this time the air

  conditioning/dehumidification process will 

  immediately stop. However, the fan motor will

  continue to operate (this is normal). Carefully move

  the unit to a drain location, remove the bottom drain

  plug and let the water drain away. Reinstall the

  bottom drain plug and restart the machine until the

  "P1" symbol disappears. If the error repeats, call for

  service.

NOTE: Make sure the hose is secure so there are 

no leaks. Direct the hose toward the drain, making 

sure that there are no kinks that will stop the water 

flowing. Place the end of the hose into the drain and 

make sure the end of the hose is down to let the 

water flow smoothly. When the continuous drain 

hose is not used, ensure that the drain plug and knob 

are installed firmly to prevent leakage.

NOTE: Be sure to reinstall the bottom drain plug 

firmly to prevent leakage before using the unit.

SLEEP/ECO operation

Содержание KSTAP05PHA

Страница 1: ...Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times KSTAP05PHA KSTAP07PHA...

Страница 2: ......

Страница 3: ...Producto...

Страница 4: ...800 849 1112 keystonecs keystone products com 800 849 1112 keystonecs keystone products com Keystone Keystone Keystone Keystone...

Страница 5: ...ou a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the troubleshooting tips you should be able to fix most of them quickly before ca...

Страница 6: ...ontrol lever adjust manually Panel Caster Bottom tray drain outlet Air filter Upper air intake air outlet Lower air intake Drain outlet Design Notice In order to ensure the optimal performance of our...

Страница 7: ...o short circuit DO NOT install the unit in a location that may be exposed to combustible gas as this could cause a fire The unit has wheels to facilitate movement Make sure not to use the wheels on th...

Страница 8: ...s or similar coverings Do not route cord under furniture or appliances Arrange the cord away from the traffic area and where it will not be tripped over Never attempt to operate this appliance if it i...

Страница 9: ...it as this could cause damage to the unit Note About Fluorinated Gasses This air conditioning unit is a hermetically sealed unit that contains fluorinated gasses For specific information on the type o...

Страница 10: ...he window requires two window sliders use the bolt to fasten the window sliders once they are adjusted to the proper length Press the exhaust hose into the window slider adaptor and the unit adaptor E...

Страница 11: ...bly Insert the window slider assembly on the left or right sides of the sash channel Use care when installing the window slider assembly which will now fit very tightly in the opening Close the sash t...

Страница 12: ...nches the exhaust system to work purposes In order to ensure the optimal performance of our products the design specifications of the unit and remote control are subject to change without prior notice...

Страница 13: ...he selected mode Used to adjust increasing decreasing temperature settings in 1 C 1 F increments in a range of 17 C 62 F to 30 C 86 F Up and Down buttons Power button Power switch on off NOTE The cont...

Страница 14: ...e this unit is made to self evaporate This means if you keep the rubber stoppers closed on the back of the unit the water will evaporate and you will not have to drain In cases of extreme humidity you...

Страница 15: ...to the desired position manually Do not place any heavy objects or other loads on the louver doing so will cause damage to the unit Keep the louver fully opened during operation Remove the drain plug...

Страница 16: ...Be sure to store the unit in a cool dark place Exposure to direct sunlight or extreme heat can shorten the lifespan of the unit Air filter take out down the grille...

Страница 17: ...hooting Tips Before calling for service review this list It may save you time and expense This list includes common problems that may not be the result of defective workmanship or materials in this ap...

Страница 18: ......

Отзывы: