Note: When one of the above malfunctions occurs, turn off the unit 

and check for any obstructions. Restart the Unit. If the malfunction 

persists, turn off the unit and unplug the power cord. Contact the 

manufacturer or its service agents or a similarly qualified person for 

service.

and read P1 on the LED display (it will stay like this until the unit is drained). If 

this happens, you should drain the water from the lower drain (located at the 

bottom of the unit).

- Press the "MODE" button until the "COOL" indicator light comes on.

- Press the Up (+) and Down (-) buttons to select your desired room temperature.

  The temperature can be set within a range of 17°C~30°C/62°F~86°F.

- Press the "FAN" button to choose the fan speed.

- Press the "MODE" button until the "DRY" indicator light comes on.

- Under this mode, you cannot select a fan speed or adjust the temperature. The fan

  motor operates at LOW speed.

- Keep windows and doors closed for the best dehumidifying effect.

- Do not connect the exhaust hose to a window.

- In cool mode, this unit is made to self-evaporate. This means if you keep the rubber 

  stoppers closed on the back of the unit, the water will evaporate and you will not 

  have to drain.

- In cases of extreme humidity, you may have some water accumulation that the unit

  is unable to evaporate. In this case, the unit will beep 8 times, switch to fan mode, 

- This feature can be activated from the remote control ONLY.

- When you set the air conditioner in AUTO mode, it will automatically select cooling or 

  fan only operation depending on what temperature you have selected and the current 

  room temperature.

- The air conditioner will control room temperature automatically according to the 

   temperature point set by you.

- Under AUTO mode, you cannot select the fan speed.

- Press the "MODE" button until the "FAN" indicator light comes on.

- Press the "FAN" button to choose the fan speed. The temperature cannot be adjusted.

- Do not connect the exhaust hose to a window.

- In COOL or DRY mode, press the "MODE" button for 3 seconds to turn on or off the 

  constant fan function. When the function is turned on, the constant fan light will illuminate, 

  identifying that the fan will continuously run for cooling.

AUTO operation

Constant Fan operation

Содержание KSTAP05PHA

Страница 1: ...Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times KSTAP05PHA KSTAP07PHA...

Страница 2: ......

Страница 3: ...Producto...

Страница 4: ...800 849 1112 keystonecs keystone products com 800 849 1112 keystonecs keystone products com Keystone Keystone Keystone Keystone...

Страница 5: ...ou a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the troubleshooting tips you should be able to fix most of them quickly before ca...

Страница 6: ...ontrol lever adjust manually Panel Caster Bottom tray drain outlet Air filter Upper air intake air outlet Lower air intake Drain outlet Design Notice In order to ensure the optimal performance of our...

Страница 7: ...o short circuit DO NOT install the unit in a location that may be exposed to combustible gas as this could cause a fire The unit has wheels to facilitate movement Make sure not to use the wheels on th...

Страница 8: ...s or similar coverings Do not route cord under furniture or appliances Arrange the cord away from the traffic area and where it will not be tripped over Never attempt to operate this appliance if it i...

Страница 9: ...it as this could cause damage to the unit Note About Fluorinated Gasses This air conditioning unit is a hermetically sealed unit that contains fluorinated gasses For specific information on the type o...

Страница 10: ...he window requires two window sliders use the bolt to fasten the window sliders once they are adjusted to the proper length Press the exhaust hose into the window slider adaptor and the unit adaptor E...

Страница 11: ...bly Insert the window slider assembly on the left or right sides of the sash channel Use care when installing the window slider assembly which will now fit very tightly in the opening Close the sash t...

Страница 12: ...nches the exhaust system to work purposes In order to ensure the optimal performance of our products the design specifications of the unit and remote control are subject to change without prior notice...

Страница 13: ...he selected mode Used to adjust increasing decreasing temperature settings in 1 C 1 F increments in a range of 17 C 62 F to 30 C 86 F Up and Down buttons Power button Power switch on off NOTE The cont...

Страница 14: ...e this unit is made to self evaporate This means if you keep the rubber stoppers closed on the back of the unit the water will evaporate and you will not have to drain In cases of extreme humidity you...

Страница 15: ...to the desired position manually Do not place any heavy objects or other loads on the louver doing so will cause damage to the unit Keep the louver fully opened during operation Remove the drain plug...

Страница 16: ...Be sure to store the unit in a cool dark place Exposure to direct sunlight or extreme heat can shorten the lifespan of the unit Air filter take out down the grille...

Страница 17: ...hooting Tips Before calling for service review this list It may save you time and expense This list includes common problems that may not be the result of defective workmanship or materials in this ap...

Страница 18: ......

Отзывы: