Keystoker – Schuylkill Haven, PA 17972
Koker, Koker Lite & Econo 90 Stoker Coal Stoves
© June 2019 REV 4
- 5 -
Installation
Stove Placement
1.
Select a position on a solid level surface with direct access to a chimney. On
non-masonry floors, use an approved fire resistant & ember resistant floor
protector under stove. Maintain 16” clearance on sides of stove to combustibles.
Zero clearance on rear and 16” clearance on front of stove. Clearance from
corners of stove is 8”. See label on stove. Refer to Figure 1.
FIGURE 1
•
Tested 7/05 TO UL 391, TESTED
8/03 TO CSA B366-m1979
•
Chimney Type: Minimum 6”
diameter approved low heat
residential type all fuel.
•
Chimney connector: 6” diameter
24 gauge blue or black steel.
•
Install at least 18 inches from
ceiling special methods are
required when passing through a
wall or ceiling