background image

Notices

© Keysight Technologies, Inc. 

2011-2017

No part of this manual may be 

reproduced in any form or by any 

means (including electronic storage 

and retrieval or translation into a 

foreign language) without prior 

agreement and written consent from 

Keysight Technologies, Inc. as 

governed by United States and 

international copyright laws.

Trademark Acknowledgments

Manual Part Number

N5222-90119

Edition

Edition 1, May 2017

Printed in USA/Malaysia

Published by:

Keysight Technologies

1400 Fountaingrove Parkway 

Santa Rosa, CA 95403

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO 

THE MAXIMUM EXTENT PERMITTED 

BY APPLICABLE LAW, KEYSIGHT 

DISCLAIMS ALL WARRANTIES, 

EITHER EXPRESS OR IMPLIED WITH 

REGARD TO THIS MANUAL AND 

ANY INFORMATION CONTAINED 

HEREIN, INCLUDING BUT NOT 

LIMITED TO THE IMPLIED 

WARRANTIES OF 

MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. 

KEYSIGHT SHALL NOT BE LIABLE 

FOR ERRORS OR FOR INCIDENTAL 

OR CONSEQUENTIAL DAMAGES IN 

CONNECTION WITH THE 

FURNISHING, USE, OR 

PERFORMANCE OF THIS 

DOCUMENT OR ANY INFORMATION 

CONTAINED HEREIN. SHOULD 

KEYSIGHT AND THE USER HAVE A 

SEPARATE WRITTEN AGREEMENT 

WITH WARRANTY TERMS 

COVERING THE MATERIAL IN THIS 

DOCUMENT THAT CONFLICT WITH 

THESE TERMS, THE WARRANTY 

TERMS IN THE SEPARATE 

AGREEMENT WILL CONTROL.

Technology Licenses

The hardware and/or software 

described in this document are 

furnished under a license and may be 

used or copied only in accordance 

with the terms of such license.

U.S. Government Rights

The Software is “commercial 

computer software,” as defined 

by Federal Acquisition Regulation 

(“FAR”) 2.101. Pursuant to FAR 

12.212 and 27.405-3 and 

Department of Defense FAR 

Supplement (“DFARS”) 227.7202, 

the U.S. government acquires 

commercial computer software 

under the same terms by which 

the software is customarily 

provided to the public. 

Accordingly, Keysight provides 

the Software to U.S. government 

customers under its standard 

commercial license, which is 

embodied in its End User License 

Agreement (EULA), a copy of 

which can be found at 

http://www.keysight.com/find/sweula

The license set forth in the EULA 

represents the exclusive authority 

by which the U.S. government 

may use, modify, distribute, or 

disclose the Software. The EULA 

and the license set forth therein, 

does not require or permit, 

among other things, that 

Keysight: (1) Furnish technical 

information related to 

commercial computer software 

or commercial computer 

software documentation that is 

not customarily provided to the 

public; or (2) Relinquish to, or 

otherwise provide, the 

government rights in excess of 

these rights customarily provided 

to the public to use, modify, 

reproduce, release, perform, 

display, or disclose commercial 

computer software or 

commercial computer software 

documentation. No additional 

government requirements 

beyond those set forth in the 

EULA shall apply, except to the 

extent that those terms, rights, or 

licenses are explicitly required 

from all providers of commercial 

computer software pursuant to 

the FAR and the DFARS and are 

set forth specifically in writing 

elsewhere in the EULA. Keysight 

shall be under no obligation to 

update, revise or otherwise 

modify the Software. With 

respect to any technical data as 

defined by FAR 2.101, pursuant 

to FAR 12.211 and 27.404.2 and 

DFARS 227.7102, the U.S. 

government acquires no greater 

than Limited Rights as defined in 

FAR 27.401 or DFAR 227.7103-5 

(c), as applicable in any technical 

data.

Safety Notices

CAUTION

 notice denotes a hazard. It 

calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in damage to the 

product or loss of important data. Do 

not proceed beyond a CAUTION 

notice until the indicated conditions 

are fully understood and met. 

WARNING

 notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in personal injury or 

death. Do not proceed beyond a 

WARNING notice until the indicated 

conditions are fully understood and 
met.

Содержание N5222-60119

Страница 1: ...eysight Add 4 Port Capability Upgrade Kit Installation Note To Upgrade PNA N5221B or N5222B Option 219 to Option 419 Upgrade Kit Order Number N5221BU 619 and N5222BU 619 Keysight Kit Number N5222 6011...

Страница 2: ...S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license set...

Страница 3: ...analyzer to a N5221B or N5222B Option 419 4 port analyzer by adding an additional source an additional source synthesizer an additional mixer brick two additional receiver couplers two additional tes...

Страница 4: ...Web at http www keysight com find assist If you do not have access to the Internet please contact your Keysight field engineer If You Have Problems With the Upgrade Kit Contents Keysight stands behin...

Страница 5: ...tware Manager http www keysight com find softwaremanager To complete the request you will need to gather the following information From the certificate Order number The PNA contains extremely sensitiv...

Страница 6: ...umber use the following steps 1 Go to www keysight com 2 In the Search box enter the model number of the analyzer Ex N5221B and click Search 3 Click Technical Support Manuals 4 Click Service Manual 5...

Страница 7: ...pen end torque wrench set to 6 in lbs 0 68 N m 1 5 8 in 16 mm nutsetter or open end torque wrench set to 21 in lbs 2 38 N m 1 1 in 25 4 mm torque wrench set to 72 in lbs 8 15 N m 1 Use a 5 16 in torqu...

Страница 8: ...pler A35 Test port 3 source attenuator 2 33321 60077 A36 Test port 4 source attenuator A39 Test port 3 bias tee includes wire harness 2 5067 4865 A40 Test port 4 bias tee includes wire harness A43 Tes...

Страница 9: ...34 Cable tie 6 1400 0249 Bracket for receiver coupler 2 N5242 00006 Bracket for attenuator assemblies 2 N5242 00007 Bulkhead connector for test set front plate hardware supplied with connector 12 1250...

Страница 10: ...W60 RF cable A20 IF multiplexer board P203 to A12 SPAM board J2 1 N5242 60013 W62 RF cable A20 IF multiplexer board P603 to A12 SPAM board J5 1 N5242 60015 W67 RF cable A10 frequency reference board...

Страница 11: ...rd J206 to A43 port 3 receiver attenuator 1 8121 0982 Ribbon cable A19 test set motherboard J207 to A44 port 4 receiver attenuator 1 8121 0982 Ribbon cable A19 test set motherboard J202 to A35 port 3...

Страница 12: ...27 Receiver Coupler Assemblies Step 12 Assemble the A35 and A36 Source Attenuators and the A43 and A44 Receiver Attenuators Step 13 Install the A39 and A40 Bias Tees A35 and A36 Source Attenuators and...

Страница 13: ...ge 5 Verify that the model number serial number and option number information on the license key match those of the instrument on which this upgrade will be installed If the model number serial number...

Страница 14: ...0 in the PDF Service Guide1 These cables may be discarded they will not be reinstalled W42 N5222 20073 A21 HMA26 5 to A23 mixer brick W48 N5222 20003 A33 reference mixer switch to A23 mixer brick R1 W...

Страница 15: ...qty 6 Front panel jumper NOTE Remove and save the cable guards for the front panel jumpers Step 7 Remove the A23 Mixer Brick Assembly Remove the A23 mixer brick assembly from the PNA For instructions...

Страница 16: ...16 Installation Note N5222 90119 Installation Procedure for the Upgrade Figure 2 A24 Mixer Brick Block Assembly cont...

Страница 17: ...tion Procedure for the Upgrade Step 9 Assemble the A26 and A27 Receiver Coupler Assemblies Follow the instructions shown in Figure 3 New parts are listed in Table 1 on page 8 of this document Figure 3...

Страница 18: ...Follow instruction 1 shown in Figure 4 New parts are listed in Table 1 on page 8 of this document Figure 4 Mixer Brick Block and Receiver Coupler Assemblies Installation Step 11 Install the A26 and A2...

Страница 19: ...cedure for the Upgrade Step 12 Assemble the A35 and A36 Source Attenuators and the A43 and A44 Receiver Attenuators Follow the five instructions shown in Figure 5 Figure 5 A35 A36 Source Attenuators A...

Страница 20: ...tep 13 Install the A39 and A40 Bias Tees A35 and A36 Source Attenuators and the A43 and A44 Receiver Attenuators Follow the instructions shown in Figure 6 Figure 6 A39 A40 Bias Tees A35 A36 Source Att...

Страница 21: ...rom the PNA For instructions click the Chapter 7 bookmark Removing and Replacing the A29 A32 Test Port Couplers in the PDF Service Guide1 2 Using pliers remove the adhesive bumper on the A29 test port...

Страница 22: ...from the 2 port test set front plate of the PNA Keep the screws and LED boards for reuse later 2 Remove the 12 bulkhead connectors nuts and washers from the 2 port front plate to reuse later 3 Remove...

Страница 23: ...new bulkhead connectors included in the kit for the remainder of this step 2 From the back side of the test set front plate insert a bulkhead connector into a hole in the plate 3 Install 1x washer an...

Страница 24: ...n Note N5222 90119 Installation Procedure for the Upgrade Step 17 Install the 4 Port Coupler Plate Assembly to the Deck Follow the four instructions shown in Figure 10 Figure 10 Coupler Plate Assembly...

Страница 25: ...nstallation Note N5222 90119 25 Installation Procedure for the Upgrade Step 18 Assemble the A8 26 5 GHz Source 2 Assembly Follow the three instructions shown in Figure 11 Figure 11 A8 Source 2 Assembl...

Страница 26: ...allation Note N5222 90119 Installation Procedure for the Upgrade Step 19 Install the A8 26 5 GHz Source 2 Assembly Follow the three instructions shown in Figure 12 Figure 12 A8 Source 2 Assembly Insta...

Страница 27: ...ly connected to J5 of the A13 source 2 synthesizer board Step 21 Install the Test Set Cables Flexible Cables Required for Upgrading to an Option 401 PNA Install the following gray flexible cables in t...

Страница 28: ...ias tee to A32 port 2 coupler W22 N5222 20018 A31 port 4 coupler to front panel Port 4 CPLR ARM W80 N5222 20020 A36 port 4 source attenuator to front panel Port 4 SOURCE OUT W50 N5222 20027 REF 4 RCVR...

Страница 29: ...e mixer switch to front panel REF 1 SOURCE OUT Refer to the note shown in Figure 13 for information on installing W35 part number N5222 20033 W17 N5222 20023 A26 port 3 receiver coupler to front panel...

Страница 30: ...cable clamps part number 1400 1334 to secure W49 part number N5222 20024 Figure 14 Location of Cable Clamps to Secure W49 W48 N5222 20101 A33 reference mixer switch to A23 mixer brick R1 As shown in...

Страница 31: ...reference mixer switch If the screws that attach the reference mixer switch to the test set deck were loosened torque these screws now to 9 in lbs W10 reuse N5222 20043 W9 to A28 port 2 receiver coupl...

Страница 32: ...4 receiver attenuator N5242 60008 A19 test set motherboard J202 to A35 port 3 source attenuator N5242 60008 A19 test set motherboard J203 to A36 port 4 source attenuator no part number A19 test set m...

Страница 33: ...ont Panel Assembly For instructions on reinstalling the front panel assembly click the Chapter 7 bookmark Removing and Replacing the Front Panel Assembly in the PDF Service Guide1 Be sure to install t...

Страница 34: ...e W30 front panel jumper cables N5222 20091 use 6 new jumpers and reuse 6 old jumpers To see an image of the front panel jumper cables click the Chapter 7 bookmark Removing and Replacing the Front Pan...

Страница 35: ...cedure 1 To start the Keysight License Manager press Start Keysight License Manager Keysight License Manager A Keysight License Manager dialog box will appear 2 Right click the on the desired option a...

Страница 36: ...m Keysight which contain license file attachments These emails are a result of Step 1 Obtain a Keyword and Verify the Information on page 13 2 Copy the license file s from the email s to the root dire...

Страница 37: ...Network Analyzer program is again running 1 On the analyzer s Help menu press About Network Analyzer 2 Verify that 419 are listed but 219 is not listed after Options in the display Click OK Attempting...

Страница 38: ...bookmark Tests and Adjustments in the PDF Service Guide1 After the specified adjustments have been performed the analyzer should operate and phase lock over its entire frequency range Operator s Check...

Страница 39: ...e PNA for the User 1 If necessary reinstall front jumper cables 2 Install the cable guards pushing them over the front jumper cables until the cushioning material touches the front panel of the PNA 3...

Страница 40: ...40 Installation Note N5222 90119 Installation Procedure for the Upgrade...

Страница 41: ...Installation Note Xxxxx xxxxx 3...

Страница 42: ...This information is subject to change without notice Keysight Technologies 2000 2017 Edition 2 May 2017 www keysight com...

Отзывы: