14
Keysight N1091APCA/BMCA/BACA/BJCA IEEE 802.3 Compliance and Debug Application Programmer's
2
Configuration Variables and Values
Configure
Pattern Length for
Jitter
RjPattern
Short, Long
Select "Short Pattern" to have the
DCA measure RJ using Jitter
Mode only to measure, such as
pattern2. Jitter will run faster and
not require a change of pattern or
option 401 or F-AEYE. Select
"Long Pattern" if you are going to
be running a longer pattern than
PRBS15, such as pattern 3. When
selecting "Long Pattern", select
under source for Rj to use option
200 or F-JIT, or a user defined Rj.
Measuring a long pattern requires
option 401 or F-AEYE.
Configure
Pattern Verification
DisablePattern
Enable, Disable
Select "Disable" to disable the
pattern verification for square 8
pattern tests and suppress
pattern error pop-ups. Select
"Enable" to ensure that the
correct pattern is being tested as
per specification.
Configure
Run Simulation
Signals
RunSim
No, Yes
Select Yes to run simulation
signals. Set simulation signals to
slot 5 (channels 5A and 5B).
Configure
SIRC Bandwidth
SIRCBW
(Accepts
user-defined text),
33e9, 25e9
Select or enter the SIRC BW. This
will automatically be applied to
any pattern lock waveform.
Configure
SIRC Response
SIRCResponse
BESSel, SINC, FLAT
Select the SIRC response. This
will automatically be applied to
any pattern lock waveform.
Configure
Samples Taken for
Eye Mode
EyeSamples
(Accepts
user-defined text),
150e3, 250e3,
500e3, 1e6, 2e6
Select or enter how many
samples are collected before
calculating eye measurement
results. Default is 250,000
samples. The range of allowable
values is 100K to 2M samples.
Configure
Save Tested
Waveforms
SaveWFM
No, Yes
Select Yes to save the waveform
files of the tested signals. Files
will be saved to directory set in
Select waveform directory.
Configure
Select Waveform
Directory
DirWFM
(Accepts
user-defined text),
C:\Temp\KRwfm
Type in a directory path to save
your measured waveforms.
Table 2
Configuration Variables and Values (continued)
GUI
Location
Label
Variable
Values
Description
Содержание N1091APCA
Страница 1: ...Keysight N1091APCA BMCA BACA BJCA IEEE 802 3 Compliance and Debug Application Programmer s Reference ...
Страница 4: ...4 Keysight N1091APCA BMCA BACA BJCA IEEE 802 3 Compliance and Debug Application Programmer s ...
Страница 6: ...6 Keysight N1091APCA BMCA BACA BJCA IEEE 802 3 Compliance and Debug Application Programmer s ...
Страница 44: ...44 Keysight N1091APCA BMCA BACA BJCA IEEE 802 3 Compliance and Debug Application Programmer s Index ...